Development of an electrochemical method for Ochratoxin A detection based on aptamer and loop-mediated isothermal amplification

被引:87
|
作者
Xie, Shunbi [1 ]
Chai, Yaqin [1 ]
Yuan, Yali [1 ]
Bai, Lijuan [1 ]
Yuan, Ruo [1 ]
机构
[1] Southwest Univ, Key Lab, Minist Educ Luminescence & Real Time Anal, Sch Chem & Chem Engn, Chongqing 400715, Peoples R China
关键词
Loop-mediated isothermal amplification; Aptamer; Electrochemical; Ochratoxin A; SINGLE-NUCLEOTIDE POLYMORPHISMS; SENSITIVE DETECTION; GOLD NANOPARTICLES; DNA; LAMP; PROBE; DIAGNOSIS; POINT; ASSAY; CARE;
D O I
10.1016/j.bios.2013.11.009
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Loop-mediated isothermal amplification (LAMP) is an outstanding DNA amplification procedure, in which the reaction can accumulate 10(9) copies from less than 10 copies of input template within an hour. While the amplification reaction is extremely powerful, the quantitative detection of LAMP products is still analytically difficult. Besides, the type of targets that LAMP can detect is also less, which to some extent limited the application of LAMP. In this study, we are reporting for the first time an efficient and accurate detection system which employs the integration of LAMP, aptamer and the electrochemical method for the sensitive detection of Ochratoxin A (OTA). Aptamers were designed as the forward outer primer to trigger the LAMP reaction, and then the LAMP amplification products were combined with a redox active molecule methylene blue (MB) and analyzed by an electrode using differential pulse voltammograms (DPV). As the reaction progresses, the MB intercalated into double-stranded regions of LAMP amplicons reduces the free MB concentration. Hence, the peak current of reaction mixture decreased with the amplification because of the slow diffusion of MB-amplified DNA complex to the electrode surface. The peak height of the current was related to the input amount of the aptamers, providing a ready means to detection the concentration of OTA. With such design, the proposed assay showed a good linear relationship within the range of 0.001-50 nM with a detection limit of 0.3 pM (defined as S/N=3) for OTA. (C) 2014 Published by Elsevier B.V.
引用
收藏
页码:324 / 329
页数:6
相关论文
共 50 条
  • [31] DEVELOPMENT AND APPLICATION OF A LOOP-MEDIATED ISOTHERMAL AMPLIFICATION METHOD FOR RAPID DETECTION OF PASTEURELLA MULTOCIDA
    Akondi, Sivaramakrishna
    Arora, Anil Kumar
    Sharma, Narinder Singh
    BUFFALO BULLETIN, 2022, 41 (02): : 319 - 327
  • [32] Development and application of a loop-mediated isothermal amplification method for rapid detection of Haemophilus parasuis
    Zhang, Jian-Min
    Shen, Hai-Yan
    Xu, Cheng-Gang
    Guo, Li-Li
    Zhang, Bin
    Li, Jing-Yi
    Chen, Ji-Dang
    Fan, Hui-Ying
    Liao, Ming
    AFRICAN JOURNAL OF BIOTECHNOLOGY, 2011, 10 (50): : 10263 - 10270
  • [33] Development of a loop-mediated isothermal amplification method for detecting virulent Rhodococcus equi
    Kinoshita, Yuta
    Niwa, Hidekazu
    Higuchi, Tohru
    Katayama, Yoshinari
    JOURNAL OF VETERINARY DIAGNOSTIC INVESTIGATION, 2016, 28 (05) : 608 - 611
  • [34] Development of Loop-Mediated Isothermal Amplification Assay for Rapid Detection of Cucurbit Leaf Crumple Virus
    Waliullah, Sumyya
    Ling, Kai-Shu
    Cieniewicz, Elizabeth J.
    Oliver, Jonathan E.
    Ji, Pingsheng
    Ali, Md Emran
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2020, 21 (05)
  • [35] Loop-Mediated Isothermal Amplification in Schistosomiasis
    Garcia-Bernalt Diego, Juan
    Fernandez-Soto, Pedro
    Febrer-Sendra, Begona
    Crego-Vicente, Beatriz
    Muro, Antonio
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (03) : 1 - 13
  • [36] Development of Loop-Mediated Isothermal Amplification-Based Lateral Flow Device Method for the Detection of Malaria
    Mallepaddi, Prudhvi Chand
    Lai, Meng-Yee
    Podha, Sudhakar
    Ooi, Choo-Huck
    Liew, Jonathan Wee-Kent
    Polavarapu, Rathnagiri
    Lau, Yee-Ling
    AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2018, 99 (03) : 704 - 708
  • [37] Modified loop-mediated isothermal amplification method combined with a TaqMan probe for the detection of Mycoplasma gallisepticum
    Liu, Yu
    Zhang, Yilin
    Wang, Man
    Shi, Guoqiang
    Dong, Zhenguo
    Ye, Lei
    Shi, Lei
    EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2023, 249 (06) : 1469 - 1477
  • [38] Development and Evaluation of a Loop-Mediated Isothermal Amplification Method for Rapid Detection of Aspergillus fumigatus
    Tang, Qing
    Tian, Shuguang
    Yu, Nong
    Zhang, Xi
    Jia, Xiaodong
    Zhai, Hongyan
    Sun, Qun
    Han, Li
    JOURNAL OF CLINICAL MICROBIOLOGY, 2016, 54 (04) : 950 - 955
  • [39] Development and evaluation of a loop-mediated isothermal amplification method for the rapid detection of Chlamydophila pneumoniae
    Kawai, Y.
    Miyashita, N.
    Kishi, F.
    Tabuchi, M.
    Oda, K.
    Yamaguchi, T.
    Kawasaki, K.
    Yamazaki, T.
    Ouchi, K.
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2009, 28 (07) : 801 - 805
  • [40] Development of a Rapid Detection Method for Potato virus X by Reverse Transcription Loop-Mediated Isothermal Amplification
    Jeong, Joojin
    Cho, Sang-Yin
    Lee, Wang-Hyu
    Lee, Kui-Jae
    Ju, Ho-Jong
    PLANT PATHOLOGY JOURNAL, 2015, 31 (03) : 219 - 225