Development of an electrochemical method for Ochratoxin A detection based on aptamer and loop-mediated isothermal amplification

被引:87
|
作者
Xie, Shunbi [1 ]
Chai, Yaqin [1 ]
Yuan, Yali [1 ]
Bai, Lijuan [1 ]
Yuan, Ruo [1 ]
机构
[1] Southwest Univ, Key Lab, Minist Educ Luminescence & Real Time Anal, Sch Chem & Chem Engn, Chongqing 400715, Peoples R China
关键词
Loop-mediated isothermal amplification; Aptamer; Electrochemical; Ochratoxin A; SINGLE-NUCLEOTIDE POLYMORPHISMS; SENSITIVE DETECTION; GOLD NANOPARTICLES; DNA; LAMP; PROBE; DIAGNOSIS; POINT; ASSAY; CARE;
D O I
10.1016/j.bios.2013.11.009
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Loop-mediated isothermal amplification (LAMP) is an outstanding DNA amplification procedure, in which the reaction can accumulate 10(9) copies from less than 10 copies of input template within an hour. While the amplification reaction is extremely powerful, the quantitative detection of LAMP products is still analytically difficult. Besides, the type of targets that LAMP can detect is also less, which to some extent limited the application of LAMP. In this study, we are reporting for the first time an efficient and accurate detection system which employs the integration of LAMP, aptamer and the electrochemical method for the sensitive detection of Ochratoxin A (OTA). Aptamers were designed as the forward outer primer to trigger the LAMP reaction, and then the LAMP amplification products were combined with a redox active molecule methylene blue (MB) and analyzed by an electrode using differential pulse voltammograms (DPV). As the reaction progresses, the MB intercalated into double-stranded regions of LAMP amplicons reduces the free MB concentration. Hence, the peak current of reaction mixture decreased with the amplification because of the slow diffusion of MB-amplified DNA complex to the electrode surface. The peak height of the current was related to the input amount of the aptamers, providing a ready means to detection the concentration of OTA. With such design, the proposed assay showed a good linear relationship within the range of 0.001-50 nM with a detection limit of 0.3 pM (defined as S/N=3) for OTA. (C) 2014 Published by Elsevier B.V.
引用
收藏
页码:324 / 329
页数:6
相关论文
共 50 条
  • [1] Ultrasensitive electrochemiluminescent aptasensor for ochratoxin A detection with the loop-mediated isothermal amplification
    Yuan, Yali
    Wei, Shiqiang
    Liu, Guangpeng
    Xie, Shunbi
    Chai, Yaqin
    Yuan, Ruo
    ANALYTICA CHIMICA ACTA, 2014, 811 : 70 - 75
  • [2] Development of a loop-mediated isothermal amplification method for the rapid detection of Pythium ultimum
    Shen, Danyu
    Li, Qingling
    Yu, Jia
    Zhao, Yuanyuan
    Zhu, Ye
    Xu, Heng
    Dou, Daolong
    AUSTRALASIAN PLANT PATHOLOGY, 2017, 46 (06) : 571 - 576
  • [3] Strategies for the Voltammetric Detection of Loop-Mediated Isothermal Amplification
    Marangoni, Jesse M. M.
    Ng, Kenneth K. S.
    Emadi, Arezoo
    MICROMACHINES, 2023, 14 (02)
  • [4] Development of an Electrochemical Sensor for SARS-CoV-2 Detection Based on Loop-Mediated Isothermal Amplification
    Rivas-Macho, Ane
    Eletxigerra, Unai
    Diez-Ahedo, Ruth
    Barros, Angela
    Merino, Santos
    Goni-de-Cerio, Felipe
    Olabarria, Garbine
    BIOSENSORS-BASEL, 2023, 13 (10):
  • [5] Detection of Mycoplasma Contamination of Cell Culture by A Loop-Mediated Isothermal Amplification Method
    Soheily, Zohre
    Soleimani, Mohammad
    Majidzadeh-Ardebili, Keivan
    CELL JOURNAL, 2019, 21 (01) : 43 - 48
  • [6] Development of a visual detection method of porcine deltacoronavirus using loop-mediated isothermal amplification
    Li, Renfeng
    Cao, Wenyan
    Yuan, Jiakang
    Li, Linyue
    Zhou, Yanlin
    Wang, Fangyu
    Wang, Ziliang
    Tian, Xiangqin
    FRONTIERS IN MICROBIOLOGY, 2024, 15
  • [7] Development of a visual detection method for Salmonella based on loop-mediated isothermal amplification using pyrophosphatase
    Liu, Wenbo
    Zhang, Shuai
    Chen, Chang
    Jin, Junhua
    Liu, Hui
    Bian, Zheng
    Qi, Wenjing
    Xie, Yuanhong
    Zhang, Hongxing
    FEMS MICROBIOLOGY LETTERS, 2023, 370
  • [8] Applications of Loop-Mediated Isothermal DNA Amplification
    Fu, Shijun
    Qu, Guanggang
    Guo, Shijin
    Ma, Lin
    Zhang, Na
    Zhang, Songlin
    Gao, Sanyang
    Shen, Zhiqiang
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2011, 163 (07) : 845 - 850
  • [9] The Development of Lyophilized Loop-mediated Isothermal Amplification Reagents for the Detection of Coxiella burnetii
    Chen, Hua-Wei
    Ching, Wei-Mei
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2016, (110):
  • [10] Development of loop-mediated isothermal amplification for rapid detection of Entamoeba histolytica
    Rivera, Windell L.
    Ong, Vanissa A.
    ASIAN PACIFIC JOURNAL OF TROPICAL MEDICINE, 2013, 6 (06) : 457 - 461