Quantifying optic nerve axons in a cat glaucoma model by a semi-automated targeted counting method

被引:0
作者
Teixeira, Leandro B. C. [1 ,2 ]
Buhr, Kevin A. [3 ]
Bowie, Owen [4 ]
Duke, Felicia D. [1 ,2 ]
Nork, T. Michael [2 ,4 ]
Dubielzig, Richard R. [1 ,2 ]
McLellan, Gillian J. [2 ,4 ,5 ]
机构
[1] Univ Wisconsin, Sch Vet Med, Dept Pathobiol Sci, Madison, WI 53792 USA
[2] Univ Wisconsin, McPherson Eye Res Inst, Madison, WI 53792 USA
[3] Univ Wisconsin, Dept Biostat & Med Informat, Madison, WI 53792 USA
[4] Univ Wisconsin, Sch Med & Publ Hlth, Dept Ophthalmol & Visual Sci, Madison, WI 53792 USA
[5] Univ Wisconsin, Sch Vet Med, Dept Surg Sci, Madison, WI 53792 USA
来源
MOLECULAR VISION | 2014年 / 20卷
关键词
RETINAL GANGLION-CELL; AMACRINE CELLS; RAT MODEL; POPULATION; ORGANIZATION; NUMBER; LAYER;
D O I
暂无
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Purpose: To describe and validate a semi-automated targeted sampling (SATS) method for quantifying optic nerve axons in a feline glaucoma model. Methods: Optic nerve cross sections were obtained from 15 cats, nine with mild to severe glaucoma and six with normal eyes. Optic nerves were dissected, fixed in paraformaldehyde and glutaraldehyde, and processed for light microscopy by resin embedding, sectioning, and staining of axon myelin sheaths with 1% p-phenylenediamine before axon quantification. Commercially available image analysis software was used as a semi-automated axon counting tool (SCT) and was first validated by comparison with a manual axon count (MAC). This counting tool was then used in a SATS method performed by three masked raters and in a semi-automated full count (SAFC) method performed by a single observer. Correlation was assessed between the SCT and MAC using a linear model and analysis of covariance (ANCOVA). Correlation between the SATS and SAFC methods was calculated and the bias, systematic errors, and variance component assessed. The intraclass correlation coefficient (ICC) was determined to establish inter-rater agreement. In addition, the time required to perform the SATS and SAFC methods was evaluated. Results: Correlation between the axon counts obtained by the SCT and MAC was strong (r = 0.9985). There was evidence of an overcounting of axons by the SCT compared to the MAC with a percentage error rate of 13.0% (95% confidence interval [CI] 11.0%, 15.1%). Both the correlation of SATS count (average per rater) to SAFC (r = 0.9891) and inter-rater agreement (ICC = 0.986) were high. The SATS method presented an overall positive counting error (p<0.001) when compared to the SAFC, consistent with a fixed percentage overestimation of 11.2% (95% CI 8.3%, 14.2%) of the full count. The average time required to quantify axons by the SATS method was 10.9 min, only 27% of that required to conduct the SAFC. Conclusions: Our data demonstrate that the SATS method provides a practical, rapid, and reliable means of estimating axon counts in the optic nerves of cats with glaucoma.
引用
收藏
页码:376 / 385
页数:10
相关论文
共 5 条
  • [1] Semi-automated counting method of axons in transmission electron microscopic images
    Kim, Chan Yun
    Rho, Seungsoo
    Lee, Naeun
    Lee, Chang-Kyu
    Sung, Youngje
    VETERINARY OPHTHALMOLOGY, 2016, 19 (01) : 29 - 37
  • [2] Automated Quantification of Optic Nerve Axons in Primate Glaucomatous and Normal Eyes-Method and Comparison to Semi-Automated Manual Quantification
    Reynaud, Juan
    Cull, Grant
    Wang, Lin
    Fortune, Brad
    Gardiner, Stuart
    Burgoyne, Claude F.
    Cioffi, George A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (06) : 2951 - 2959
  • [3] AxonQuantifier: A semi-automated program for quantifying axonal density from whole-mounted optic nerves
    Peng, Micalla G.
    Lee, Jonathan
    Ho, Wilson
    Kim, Timothy
    Yao, Petcy
    Medvidovic, Sasha
    Alas, Basheer
    Wu, Vivian
    Runner, Margaret M.
    Gokoffski, Kimberly K.
    JOURNAL OF NEUROSCIENCE METHODS, 2023, 394
  • [4] A freely available semi-automated method for quantifying retinal ganglion cells in entire retinal flatmounts
    Geeraerts, E.
    Dekeyster, E.
    Gaublomme, D.
    Salinas-Navarro, M.
    De Groef, L.
    Moons, L.
    EXPERIMENTAL EYE RESEARCH, 2016, 147 : 105 - 113
  • [5] Retinal ganglion cells downregulate gene expression and lose their Axons within the optic nerve head in a mouse glaucoma model
    Soto, Ileana
    Oglesby, Ericka
    Buckingham, Brian P.
    Son, Janice L.
    Roberson, Elisha D. O.
    Steele, Michael R.
    Inman, Denise M.
    Vetter, Monica L.
    Horner, Philip J.
    Marsh-Armstrong, Nicholas