Suitability evaluation of cold sources in green buildings based on a field study

被引:1
作者
Lu, Shilei [1 ,2 ]
Su, Na [1 ,2 ]
Li, Yuwei [1 ,2 ]
Liu, Yang [1 ,2 ]
Wang, Ran [1 ,2 ]
机构
[1] Tianjin Univ, Sch Environm Sci & Engn, 92 Weijin Rd, Tianjin 300072, Peoples R China
[2] Tianjin Univ, Tianjin Key Lab Built Environm & Energy Applicat, Tianjin, Peoples R China
来源
JOURNAL OF BUILDING ENGINEERING | 2020年 / 32卷
基金
国家重点研发计划;
关键词
Green building; Cold source; Suitability evaluation; Chiller; GSHP; HEAT-PUMP SYSTEMS; CHILLER SYSTEM; PERFORMANCE; WATER;
D O I
10.1016/j.jobe.2020.101795
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The cold source is important for saving building energy, especially since green buildings put forward higher requirements that the nominal coefficient of performance (COP) of the cold source should be 6% higher than that of conventional buildings. However, due to the uncontrollability of the operation stage, the actual COP generally has a gap with the nominal COP. Summarizing the operating rules of high performance cold sources and considering them in the design stage has great significance in choosing a cold source. Through continuous testing, this paper obtained the operating data of 11 green buildings' cold sources in China and proposed a suitability evaluation method for a reasonable choice of cold source. The results show that the time of ground source heat pump (GSHP) and chiller of actual hourly COP are greater than or equal to the nominal COP at 33.3% and 11.3%, respectively. Besides, it has be found that as the cold source's average load rate (ALR) increases, the ratio of measured seasonal energy efficiency ratio (SEER) to nominal COP shows an upward trend. In cases of lower ALR, when there is a significant positive correlation between electricity consumption and load rate, the ratios of the SEER to the nominal COP are higher than 0.9. Therefore, this paper proposed a suitability evaluation method. The cold source should match building loads as much as possible, but when building loads change greatly and cannot be matched, the cold source that can adjust the power consumption with the load rate should be selected.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Research on an evaluation system of the application effect of ground source heat pump systems for green buildings in China
    Liu, Xin
    Zuo, Yuning
    Yin, Zekai
    Liang, Chuanzhi
    Feng, Guohui
    Yang, Xiaodan
    ENERGY, 2023, 262
  • [32] Beyond efficiency: Evaluation of the electricity saving potential of green residential buildings
    Bogin, Diana
    Dorman, Michael
    Kissinger, Meidad
    Erell, Evyatar
    ENERGY AND BUILDINGS, 2024, 320
  • [33] Energy Sustainability of Bio-Based Building Materials in the Cold and Severe Cold Regions of China-A Case Study of Residential Buildings
    Guo, Haibo
    Zhou, Siyuan
    Qin, Tongyu
    Huang, Lu
    Song, Wenjie
    Yin, Xunzhi
    APPLIED SCIENCES-BASEL, 2020, 10 (05):
  • [34] Land Reclamation Suitability Evaluation based on the Limit Method
    Shidai
    SUSTAINABLE DEVELOPMENT OF URBAN INFRASTRUCTURE, PTS 1-3, 2013, 253-255 : 1069 - 1074
  • [35] Urban Land Suitability Evaluation Based on BP Network
    Wang, Yan
    Cao, Junru
    Song, Zhenbai
    Wu, Peilin
    2009 17TH INTERNATIONAL CONFERENCE ON GEOINFORMATICS, VOLS 1 AND 2, 2009, : 1070 - +
  • [36] SUSTAINABLE DEVELOPMENT THROUGH GREEN BUILDINGS: UPDATED BIBLIOMETRIC ANALYSIS OF THE LITERATURE IN THE FIELD
    Bungau, Constantin C.
    Bungau, Tudor
    Prada, Marcela Florina
    Prada, Ioana Francesca
    Moleriu, Radu Dumitru
    REVISTA ROMANA DE MATERIALE-ROMANIAN JOURNAL OF MATERIALS, 2023, 53 (01): : 82 - 93
  • [37] GIS based evaluation of land suitability: A case study for major crops in Zanjan University region
    Saremi, Hanieh
    Kumar, Lalit
    Sarmadian, Fereydoon
    Heidari, Ahmad
    Shabani, Farzin
    JOURNAL OF FOOD AGRICULTURE & ENVIRONMENT, 2011, 9 (01): : 741 - 744
  • [38] Multidimensional performance-based evaluation method of high-performance cold source in green building
    Lu, Shilei
    Liu, Yang
    Li, Yuwei
    Wang, Ran
    ENERGY AND BUILDINGS, 2021, 231
  • [39] Contractor selection for green buildings based on the fuzzy Kano model and TOPSIS: a developer satisfaction perspective
    Cai, Jin
    Li, Zhongfu
    Dou, Yudan
    Teng, Yue
    Yuan, Mengqi
    ENGINEERING CONSTRUCTION AND ARCHITECTURAL MANAGEMENT, 2023, 30 (10) : 5073 - 5108
  • [40] Comparative study on the indoor environment quality of green office buildings in China with a long-term field measurement and investigation
    Pei, Zufeng
    Lin, Borong
    Liu, Yanchen
    Zhu, Yingxin
    BUILDING AND ENVIRONMENT, 2015, 84 : 80 - 88