Reproducibility and Sensitivity of the 6-Minute Stepper Test in Patients with COPD

被引:33
|
作者
Coquart, Jeremy B. [1 ]
Lemaitre, Frederic [1 ]
Castres, Ingrid [1 ]
Saison, Sylvain [2 ]
Bart, Frederic [2 ,3 ]
Grosbois, Jean-Marie [2 ,3 ]
机构
[1] Univ Rouen, Fac Sci Sport & Educ Phys, Ctr Etud Transformat Act Phys & Sport, Mont St Aignan, France
[2] Ctr Hosp Germon & Gauthier, Serv Rehabil Pluridisciplinaire, Bethune, France
[3] Ctr Hosp Germon & Gauthier, Serv Pneumol, Bethune, France
关键词
exercise text; field test; functional capacity; pulmonary rehabilitation; reliability; OBSTRUCTIVE PULMONARY-DISEASE; WALK TEST; EXERCISE; REHABILITATION; OXYGEN; PROGRAM;
D O I
10.3109/15412555.2014.974733
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
The aims of this study were to test the reproducibility of the 6-minute stepper test (6MST), and evaluate its accuracy in detecting improved functional capacity after pulmonary rehabilitation (PR) in patients with chronic obstructive pulmonary disease (COPD). Thirty-five COPD outpatients performed two 6MSTs in the same session, before (6MST(1) and 6MST(2)) and after (6MST(3) and 6MST(4)) PR. The performance, perceived exertion, heart rate and arterial oxygen saturation were measured during each 6MST. The performance was higher during the second 6MST of the same session (before PR: 514 strokes during the 6MST(2) > 471 strokes during the 6MST1, and after PR: 559 strokes during the 6MST(4) > 508 strokes during the 6MST(3); p = 0.04). After PR, 6MST performance was higher than before PR (6MST(3) > 6MST(1) and 6MST(4) > 6MST(2); P < 0.01). The bias (the difference in the number of strokes) between the two 6MSTs from the same session (before PR: 6MST(2)-6MST(1) = 42 strokes vs after PR: 6MST(4)-6MST(3) = 52 strokes) was not different (P = 0.34). However, both bias were greater than 0 (P < 0.001). The mean performances for the two 6MSTs of the same session (before PR: 6MST(1) and 6MST(2) and after PR: 6MST(3) and 6MST(4)) were correlated with the bias between these performances (P< 0.01; r = 0.32). The perceived exertions were lower after PR (P < 0.02). The systematic improvement of performance (8-10%) during the second 6MST of the each session may be explained from the warming of hydraulic jacks of the stepper and/or learning effect. On the other hand, the 6MST seems sufficiently sensitive to detect functional capacity improvements after PR in patients with COPD.
引用
收藏
页码:533 / 538
页数:6
相关论文
共 50 条
  • [21] Does the 6-minute walk test predict nocturnal oxygen desaturation in patients with moderate to severe COPD?
    Iliaz, Sinem
    Cagatay, Tulin
    Bingol, Zuleyha
    Okumus, Gulfer
    Iliaz, Raim
    Kuran, Goksen
    Kiyan, Esen
    Cagatay, Penbe
    CHRONIC RESPIRATORY DISEASE, 2015, 12 (01) : 61 - 68
  • [22] Assessment of parameters of lung ventilation during 6-minute walk test in patients with COPD
    Ponomareva, Irina
    Abrosimov, Vladimir
    Peregudova, Natalia
    EUROPEAN RESPIRATORY JOURNAL, 2015, 46
  • [23] Can we use the 6-minute step test instead of the 6-minute walking test? An observational study
    da Costa, C. H.
    da Silva, K. M.
    Maiworm, A.
    Raphael, Y.
    Parnayba, J.
    Da Cal, M.
    Figueira, B.
    Condesso, D.
    Rufino, R.
    PHYSIOTHERAPY, 2017, 103 (01) : 48 - 52
  • [24] Should the 6-Minute Walk Test Be Compared When Conducted by 2 Different Assessors in Subjects With COPD?
    Labadessa, Ivana G.
    Arcuri, Juliano F.
    Sentanin, Anna Claudia
    da Costa, Joyce N. F.
    Pessoa, Bruna V.
    Pires Di Lorenzo, Valeria Amorim
    RESPIRATORY CARE, 2016, 61 (10) : 1323 - 1330
  • [25] Different COPD Disease Characteristics are Related to Different Outcomes in the 6-minute Walk Test
    Waatevik, Marie
    Johannessen, Ane
    Hardie, Jon A.
    Bjordal, Jan Magnus
    Aukrust, Pal
    Bakke, Per S.
    Eagan, Tomas M. L.
    COPD-JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2012, 9 (03) : 227 - 234
  • [26] Intra- and inter-rater reproducibility of the 6-minute walk test and the 30-second sit-to-stand test in patients with severe and very severe COPD
    Hansen, Henrik
    Beyer, Nina
    Frolich, Anne
    Godtfredsen, Nina
    Bieler, Theresa
    INTERNATIONAL JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2018, 13 : 3447 - 3457
  • [27] Dynamic hyperinflation induced by the 6-minute pegboard and ring test in hospitalized patients with exacerbated COPD
    de Barros, Cassia Fabiane
    Felisberto, Rosimeire Marcos
    Albanezi Nucci, Kelly Cristina
    Pereira de Albuquerque, Andre Luis
    Paulin, Elaine
    Moran de Brito, Christina May
    Yamaguti, Wellington Pereira
    PLOS ONE, 2020, 15 (11):
  • [28] Analysis of 6-Minute Walk Test Safety in Pre-Heart Transplantation Patients
    Cipriano, Gerson, Jr.
    Yuri, Darlene
    Bernardelli, Graziella Franca
    Mair, Vanessa
    Buffolo, Enio
    Rodrigues Branco, Joao Nelson
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2009, 92 (04) : 294 - 300
  • [29] Reliability of the 6-minute walk test in patients referred for pulmonary rehabilitation
    van der Schoot, H. J. M.
    van Ranst, D.
    Otten, H. J.
    Stoop, W. A.
    van de Port, I. G.
    Meijer, J. W.
    EUROPEAN RESPIRATORY JOURNAL, 2012, 40
  • [30] ASSISTED 6-MINUTE CYCLING TEST: AN EXPLORATORY STUDY IN CHILDREN
    Dirks, Ilse
    Koene, Saskia
    Verbruggen, Renee
    Smeitink, Jan A. M.
    Jansen, Merel
    De Groot, Imelda J. M.
    MUSCLE & NERVE, 2016, 54 (02) : 232 - 238