Reproducibility and Sensitivity of the 6-Minute Stepper Test in Patients with COPD

被引:33
|
作者
Coquart, Jeremy B. [1 ]
Lemaitre, Frederic [1 ]
Castres, Ingrid [1 ]
Saison, Sylvain [2 ]
Bart, Frederic [2 ,3 ]
Grosbois, Jean-Marie [2 ,3 ]
机构
[1] Univ Rouen, Fac Sci Sport & Educ Phys, Ctr Etud Transformat Act Phys & Sport, Mont St Aignan, France
[2] Ctr Hosp Germon & Gauthier, Serv Rehabil Pluridisciplinaire, Bethune, France
[3] Ctr Hosp Germon & Gauthier, Serv Pneumol, Bethune, France
关键词
exercise text; field test; functional capacity; pulmonary rehabilitation; reliability; OBSTRUCTIVE PULMONARY-DISEASE; WALK TEST; EXERCISE; REHABILITATION; OXYGEN; PROGRAM;
D O I
10.3109/15412555.2014.974733
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
The aims of this study were to test the reproducibility of the 6-minute stepper test (6MST), and evaluate its accuracy in detecting improved functional capacity after pulmonary rehabilitation (PR) in patients with chronic obstructive pulmonary disease (COPD). Thirty-five COPD outpatients performed two 6MSTs in the same session, before (6MST(1) and 6MST(2)) and after (6MST(3) and 6MST(4)) PR. The performance, perceived exertion, heart rate and arterial oxygen saturation were measured during each 6MST. The performance was higher during the second 6MST of the same session (before PR: 514 strokes during the 6MST(2) > 471 strokes during the 6MST1, and after PR: 559 strokes during the 6MST(4) > 508 strokes during the 6MST(3); p = 0.04). After PR, 6MST performance was higher than before PR (6MST(3) > 6MST(1) and 6MST(4) > 6MST(2); P < 0.01). The bias (the difference in the number of strokes) between the two 6MSTs from the same session (before PR: 6MST(2)-6MST(1) = 42 strokes vs after PR: 6MST(4)-6MST(3) = 52 strokes) was not different (P = 0.34). However, both bias were greater than 0 (P < 0.001). The mean performances for the two 6MSTs of the same session (before PR: 6MST(1) and 6MST(2) and after PR: 6MST(3) and 6MST(4)) were correlated with the bias between these performances (P< 0.01; r = 0.32). The perceived exertions were lower after PR (P < 0.02). The systematic improvement of performance (8-10%) during the second 6MST of the each session may be explained from the warming of hydraulic jacks of the stepper and/or learning effect. On the other hand, the 6MST seems sufficiently sensitive to detect functional capacity improvements after PR in patients with COPD.
引用
收藏
页码:533 / 538
页数:6
相关论文
共 50 条
  • [1] Reproducibility of 6-minute walking test in patients with COPD
    Hernandes, N. A.
    Wouters, E. F. M.
    Meijer, K.
    Annegarn, J.
    Pitta, F.
    Spruit, M. A.
    EUROPEAN RESPIRATORY JOURNAL, 2011, 38 (02) : 261 - 267
  • [2] Reproducibility of Cadence-Free 6-Minute Step Test in Subjects with COPD
    da Costa, Joyce N. F.
    Arcuri, Juliano F.
    Goncalves, Ivana L.
    Davi, Simone F.
    Pessoa, Bruna V.
    Jamami, Mauricio
    Di Lorenzo, Valeria A. P.
    RESPIRATORY CARE, 2014, 59 (04) : 538 - 542
  • [3] Comparison of 3-minute Step Test (3MStepT) and 6-minute Walk Test (6MWT) in Patients with COPD
    Beaumont, Marc
    Losq, Antoine
    Peran, Loic
    Berriet, Anne-Cecile
    Couturaud, Francis
    Le Ber, Catherine
    Reychler, Gregory
    COPD-JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2019, 16 (3-4) : 266 - 271
  • [4] Reproducibility of the 6-Minute Walk Test for Ambulatory Oxygen Prescription
    Chatterjee, Arjun B.
    Rissmiller, Richard W.
    Meade, Kyle
    Paladenech, Connie
    Conforti, John
    Adair, Norman E.
    Haponik, Edward F.
    Chin, Robert, Jr.
    RESPIRATION, 2010, 79 (02) : 121 - 127
  • [5] Responsiveness and Minimally Important Difference of the 6-Minute Stepper Test in Patients with Chronic Obstructive Pulmonary Disease
    Pichon, Romain
    Couturaud, Francis
    Mialon, Philippe
    Le Ber-Moy, Catherine
    Peran, Loic
    Lochon, Chantal
    Nowak, Emmanuel
    Beaumont, Marc
    RESPIRATION, 2016, 91 (05) : 367 - 373
  • [6] Reproducibility of the 6-minute walk test in lung transplant recipients
    Ebenbichler, Gerold R.
    Murakoezy, Gabriella
    Kohlmann, Julia
    Habenicht, Richard
    Kienbacher, Thomas
    Jaksch, Peter
    Mair, Patrick
    Hoetzenecker, Konrad
    WIENER KLINISCHE WOCHENSCHRIFT, 2023, 135 (19-20) : 517 - 527
  • [7] Asynchronous Thoraco-abdominal Motion Contributes to Decreased 6-Minute Walk Test in Patients With COPD
    Chien, Jung-Yien
    Ruan, Sheng-Yuan
    Huang, Yuh-Chin T.
    Yu, Chong-Jen
    Yang, Pan-Chyr
    RESPIRATORY CARE, 2013, 58 (02) : 320 - 326
  • [8] Reproducibility and Validity of the 6-Minute Stationary Walk Test Associated With Virtual Reality in Subjects With COPD
    Frade, Maria C. M.
    dos Reis, Ivanize M. M.
    Basso-Vanelli, Renata P.
    Brandao, Alexandre F.
    Jamami, Mauricio
    RESPIRATORY CARE, 2019, 64 (04) : 425 - 433
  • [9] Six-minute stepper test: a valid clinical exercise tolerance test for COPD patients
    Grosbois, J. M.
    Riquier, C.
    Chehere, B.
    Coquart, J.
    Behal, H.
    Bart, F.
    Wallaert, B.
    Chenivesse, C.
    INTERNATIONAL JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2016, 11 : 657 - 663
  • [10] Reproducibility of the 6-minute walk test in lung transplant recipients
    Gerold R. Ebenbichler
    Gabriella Murakoezy
    Julia Kohlmann
    Richard Habenicht
    Thomas Kienbacher
    Peter Jaksch
    Patrick Mair
    Konrad Hoetzenecker
    Wiener klinische Wochenschrift, 2023, 135 : 517 - 527