The importance of static lung inflation during organ storage - The impact of varying intervals in a double lung rat transplantation model

被引:16
作者
Hausen, B
Ramsamooj, R
Hewitt, CW
Schroder, F
Beuke, M
Poets, CF
Schafers, HJ
机构
[1] HANNOVER MED SCH, DIV THORAC & CARDIOVASC SURG, SURG CTR, D-30623 HANNOVER, GERMANY
[2] HANNOVER MED SCH, DEPT PEDIAT PULM MED, D-30623 HANNOVER, GERMANY
[3] UNIV MED & DENT NEW JERSEY, ROBERT WOOD JOHNSON MED SCH, DEPT SURG, DIV SURG RES, CAMDEN, NJ 08103 USA
关键词
D O I
10.1097/00007890-199612270-00004
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
To determine the importance of static lung inflation during storage, graft, performance was evaluated at different levels of intratracheal pressure and varying. ischemic intervals, Lewis rat lungs were perfused with low-potassium Euro-Collins and stored for 4 or 8 hr either in atelectasis (4 hr: group I; 8 hr: group IV, respectively) or 13 (group II; V) or 26 cmH(2)O of airway pressure (groups III, VI), Following implantation continuous measurement of alveolar-arterial oxygen difference (AaDO(2)*) and pulmonary vascular resistance (PVR) were performed, Separate ventilation allowed assessment of mechanical lung function of the graft, At the end of reperfusion (120 min) weight gain, histology, and phospholipid and protein content in the pulmonary lavage were compared between the groups, Despite significant differences in survival at 4 hr of ischemia graft function did not differ in groups I to III, In contrast, static inflation had a significant impact after 8 hr of ischemia, Lungs stored in. atelectasis (group IV) could not be reperfused and failed immediately, Survival in group V was 83+/-11 versus 107+/-7 min in group VI (P<0.05). Compliance at 80 min was 27+/-3 in group V and 52+/-6 ml/cmH(2)O in group VI (P<0.02). Corresponding values for PVR were 232+/-92 and 112+/-16 mmHg/ml/min, respectively (P<0.05). Less inflation and longer ischemia resulted in a reduction of the large to small phospholipid aggregate ratio and deterioration of surfactant function in the bubble surfactometer, In conclusion, while the amount of static lung inflation may not be critical following short ischemia, the performance of the graft improves significantly with full inflation (26 cmH(2)O) following extended ischemia (8 hr).
引用
收藏
页码:1720 / 1725
页数:6
相关论文
共 24 条
[1]  
BARTLETT GR, 1959, J BIOL CHEM, V234, P466
[2]   MEASURING THE MECHANICAL-PROPERTIES OF THE LUNG IN-VIVO WITH SPATIAL-RESOLUTION AT THE ACINAR LEVEL [J].
BATES, JHT ;
MISHIMA, M ;
BALASSY, Z .
PHYSIOLOGICAL MEASUREMENT, 1995, 16 (03) :151-159
[3]  
BONSER RS, 1990, J HEART TRANSPLANT, V9, P220
[4]  
COOPER JD, 1992, CLIN TRANSPLANT, V77, P122
[5]   PULMONARY TRANSPLANTATION [J].
DAVIS, RD ;
PASQUE, MK .
ANNALS OF SURGERY, 1995, 221 (01) :14-28
[6]   PULSATING BUBBLE TECHNIQUE FOR EVALUATING PULMONARY SURFACTANT [J].
ENHORNING, G .
JOURNAL OF APPLIED PHYSIOLOGY, 1977, 43 (02) :198-203
[7]  
ERASMUS ME, 1994, J HEART LUNG TRANSPL, V13, P791
[8]   ELASTIC BEHAVIOR OF THE TRANSPLANTED LUNG - EXPONENTIAL ANALYSIS OF STATIC PRESSURE-VOLUME RELATIONSHIPS [J].
GLANVILLE, AR ;
THEODORE, J ;
HARVEY, J ;
ROBIN, ED .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1988, 137 (02) :308-312
[9]   FREE RADICAL-MEDIATED VASCULAR INJURY IN LUNGS PRESERVED AT MODERATE HYPOTHERMIA [J].
HANIUDA, M ;
DRESLER, CM ;
MIZUTA, T ;
COOPER, JD ;
PATTERSON, GA .
ANNALS OF THORACIC SURGERY, 1995, 60 (05) :1376-1381
[10]   Double-lung transplantation in the rat: An acute, syngeneic in situ model [J].
Hausen, B ;
Demertzis, S ;
Schroder, F ;
Beuke, M ;
Schafers, HJ .
ANNALS OF THORACIC SURGERY, 1996, 61 (01) :184-189