Revision of failed acetabular components utilizing a cementless oblong cup: an average 9-year follow-up study

被引:13
作者
Koester, Georg [1 ]
Rading, Sabine [1 ]
机构
[1] Chirurg Orthopad Fachklin Lorsch, Abt Orthopad Chirurg & Traumatol, D-64653 Lorsch, Germany
关键词
Hip; Revision; Acetabular defects; Oblong cup; Long-term results; TOTAL HIP-ARTHROPLASTY; REINFORCEMENT RING; RECONSTRUCTION; REPLACEMENT; ALLOGRAFTS; FAILURE; DEFECTS; 5-YEAR; SURGERY;
D O I
10.1007/s00402-008-0624-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Failure of acetabular components often leads to bone loss with extensive elongated defects in the surrounding bone. In these cases, reconstruction is challenging and stable fixation of the revision implant difficult. The use of an oblong cup has been described as an option for acetabular reconstruction in such revisions. We report the first long-term results obtained with this implant to date. Fifty-six longitudinal oblong revision cups (LOR (TM)) were evaluated clinically and radiologically after a follow-up of 8-12 years (average 9 years). The defects treated with the LOR (TM) cup ranged from Paprosky type 1-3. Allogenic cancellous bone chips were additionally used in 31 reconstructions to fill cavitary defects. Based on radiological criteria, 50 acetabular implants underwent osseointegration without any definitive signs of loosening; 2 consistently exhibited zonal radiolucent lines that were always smaller than 2 mm, 1 migrated by around 3 mm. None of these cases exhibited any clinical symptoms. In 11 cases where acetabular defects manifested postoperatively, 8 were remodeled completely and 3 partially at final follow-up. Three revision implants migrated farther than 5 mm and had to be revised before 32-month follow-up. In addition, 1 septic implant failure occurred. After an average follow-up of 9 years, 93% of the investigated implants remained in situ without further revision and 95% without aseptic implant failure. This 12-year clinical study demonstrates that the LOR (TM) cup offers a successful concept for the revision of failed acetabular components that also promotes the biological reconstruction of bony defects. Compared with other methods with similarly long follow-ups, our long-term results prove this procedure has a very low rate of revision and aseptic implant failure.
引用
收藏
页码:603 / 608
页数:6
相关论文
共 50 条
  • [41] Acetabular Revision Arthroplasty Using an Uncemented Deep Profile Jumbo Component: A Ten to Sixteen Year Follow-Up Study
    McLaughlin, Jeffrey R.
    Lee, Kyla R.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (02) : 496 - 499
  • [42] Modular cementless cup for total hip arthroplasty: Results at 4-year follow-up
    Bistolfi A.
    Massazza G.
    Rosso F.
    Ventura S.
    Lagalla F.
    Crova M.
    MUSCULOSKELETAL SURGERY, 2012, 96 (2) : 89 - 94
  • [43] A comparative study of "plasmacup'' and "porous-coated'' acetabular components: survival after 10 to 12 years of follow-up
    Negreiros Vicente, Jose Ricardo
    Soares Ulhoa, Carlos Antonio
    Katz, Marcio
    Addeo, Renato Dainesi
    Croci, Alberto Tesconi
    CLINICS, 2010, 65 (11) : 1111 - 1114
  • [44] Shape-memory sawtooth-arm embracing clamp used in complex femoral revision hip arthroplasty for stem stability: average 9-year follow-up study
    Hu, Yi
    Xu, Zhengquan
    Qiao, Hua
    Kong, Keyu
    Li, Huiwu
    Zhang, Jingwei
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [45] Acetabular Distraction Technique: A Multicenter Study With a Minimum 2-Year Radiographic Follow-Up
    Melnic, Christopher M.
    Salimy, Mehdi S.
    Minutillo, Gregory T.
    Paprosky, Wayne G.
    Sheth, Neil P.
    JOURNAL OF ARTHROPLASTY, 2024, 39 (09) : S398 - S403
  • [46] Revision Total Hip Arthroplasty Using an Acetabular Reinforcement Ring With a Hook: A Precise Follow-Up, at Average 11.4 Years, of a Previous Report
    Park, Kyung-Soon
    Seon, Jong-Keun
    Lee, Keun-Bae
    Kim, Sung-Kyu
    Chan, Chee-Ken
    Yoon, Taek-Rim
    JOURNAL OF ARTHROPLASTY, 2017, 32 (02) : 503 - 509
  • [47] Highly Cross-Linked Polyethylene in Cementless Total Hip Arthroplasty in Patients with Previous Acetabular Fractures: A Minimum 5-Year Follow-Up Study
    Min, Byung-Woo
    Bae, Ki-Cheor
    Cho, Chul-Hyun
    Son, Eun-Suck
    Lee, Kyung-Jae
    Lee, Si-Wook
    INDIAN JOURNAL OF ORTHOPAEDICS, 2020, 54 (SUPPL 2) : 239 - 245
  • [48] Standardized 3D-printed trabecular titanium augment and cup for acetabular bone defects in revision hip arthroplasty: a mid-term follow-up study
    Hao, Linjie
    Zhang, Yumin
    Bian, Weiguo
    Song, Wei
    Li, Kun
    Wang, Nengjun
    Wen, Pengfei
    Ma, Tao
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [49] Cementless Metal-Backed Patellar Components in Primary Total Knee Arthroplasty: An Average 10-Year Follow-Up
    Jouflas, Alex C.
    Nadar, Arun C.
    Royster, Brett W.
    Smith, Langan S.
    Ziegele, Michael J.
    Yakkanti, Madhusudhan R.
    Malkani, Arthur L.
    JOURNAL OF ARTHROPLASTY, 2023, 38 (06) : S137 - S144
  • [50] Long-term outcomes of acetabular impaction grafting with cemented cups and trabecular metal for revision hip arthroplasty: a follow-up study
    Curtin, Mark
    Russell, Shane P.
    Mirdad, Rayyan S.
    Irwin, Shane C.
    Rowan, Fiachra E.
    Masterson, Eric L.
    Condon, Finbarr
    HIP INTERNATIONAL, 2024, 34 (06) : 764 - 771