Revision of failed acetabular components utilizing a cementless oblong cup: an average 9-year follow-up study

被引:13
作者
Koester, Georg [1 ]
Rading, Sabine [1 ]
机构
[1] Chirurg Orthopad Fachklin Lorsch, Abt Orthopad Chirurg & Traumatol, D-64653 Lorsch, Germany
关键词
Hip; Revision; Acetabular defects; Oblong cup; Long-term results; TOTAL HIP-ARTHROPLASTY; REINFORCEMENT RING; RECONSTRUCTION; REPLACEMENT; ALLOGRAFTS; FAILURE; DEFECTS; 5-YEAR; SURGERY;
D O I
10.1007/s00402-008-0624-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Failure of acetabular components often leads to bone loss with extensive elongated defects in the surrounding bone. In these cases, reconstruction is challenging and stable fixation of the revision implant difficult. The use of an oblong cup has been described as an option for acetabular reconstruction in such revisions. We report the first long-term results obtained with this implant to date. Fifty-six longitudinal oblong revision cups (LOR (TM)) were evaluated clinically and radiologically after a follow-up of 8-12 years (average 9 years). The defects treated with the LOR (TM) cup ranged from Paprosky type 1-3. Allogenic cancellous bone chips were additionally used in 31 reconstructions to fill cavitary defects. Based on radiological criteria, 50 acetabular implants underwent osseointegration without any definitive signs of loosening; 2 consistently exhibited zonal radiolucent lines that were always smaller than 2 mm, 1 migrated by around 3 mm. None of these cases exhibited any clinical symptoms. In 11 cases where acetabular defects manifested postoperatively, 8 were remodeled completely and 3 partially at final follow-up. Three revision implants migrated farther than 5 mm and had to be revised before 32-month follow-up. In addition, 1 septic implant failure occurred. After an average follow-up of 9 years, 93% of the investigated implants remained in situ without further revision and 95% without aseptic implant failure. This 12-year clinical study demonstrates that the LOR (TM) cup offers a successful concept for the revision of failed acetabular components that also promotes the biological reconstruction of bony defects. Compared with other methods with similarly long follow-ups, our long-term results prove this procedure has a very low rate of revision and aseptic implant failure.
引用
收藏
页码:603 / 608
页数:6
相关论文
共 50 条
  • [31] Delayed total hip arthroplasty after failed treatment of acetabular fractures: an 8-to 17-year follow-up study
    Wang, Tao
    Sun, Jun-Ying
    Zha, Jun-Jun
    Wang, Chao
    Zhao, Xi-Jiang
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2018, 13
  • [32] Use of porous tantalum components in Paprosky two and three acetabular revision. A minimum five-year follow-up of fifty one hips
    Flecher, Xavier
    Appy, Benjamin
    Parratte, Sebastien
    Ollivier, Matthieu
    Argenson, Jean-Noel
    INTERNATIONAL ORTHOPAEDICS, 2017, 41 (05) : 911 - 916
  • [33] Comparison of Outcome and Survival After Unicompartmental Knee Arthroplasty Between Navigation and Conventional Techniques With an Average 9-Year Follow-Up
    Song, Eun Kyoo
    Mohite, N.
    Lee, Seung-Hun
    Na, Bo-Ram
    Seon, Jong-Keun
    JOURNAL OF ARTHROPLASTY, 2016, 31 (02) : 395 - 400
  • [34] The Burch-Schneider cage: 9-year survival in Paprosky type 3 acetabular defects. Clinical and radiological follow-up
    Jones, Luke
    Grammatopoulos, George
    Singer, Gian
    HIP INTERNATIONAL, 2012, 22 (01) : 28 - 34
  • [35] Short Term Outcomes (Average Follow-Up of 2.4 Years) of a Constrained Acetabular Liner in Primary and Revision Total Hip Arthroplasty
    Maniar, Adit R.
    Kazarian, Gregory S.
    Torres-Ramirez, Ricardo J.
    Ranawat, Amar S.
    JOURNAL OF ARTHROPLASTY, 2023, 38 (07) : S142 - S145
  • [36] Total Hip Arthroplasty for Failed Treatment of Acetabular Fractures A 5-Year Follow-Up Study
    Zhang, Liang
    Zhou, Yixin
    Li, Yujun
    Xu, Hui
    Guo, Xiaozhong
    Zhou, Yixiong
    JOURNAL OF ARTHROPLASTY, 2011, 26 (08) : 1189 - 1193
  • [37] Revision anterior cruciate ligament reconstruction with hamstring tendon autograft - 5- to 9-year follow-up
    Salmon, Lucy J.
    Pinczewski, Leo A.
    Russell, Vivianne J.
    Refshauge, Kathryn
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2006, 34 (10) : 1604 - 1614
  • [38] Total Hip Arthroplasty Using Modular Trabecular Metal Acetabular Components for Failed Treatment of Acetabular Fractures: A Mid-term Follow-up Study
    Huang, De-Yong
    Zhang, Liang
    Zhou, Yi-Xin
    Zhang, Chun-Yu
    Xu, Hui
    Huang, Yong
    CHINESE MEDICAL JOURNAL, 2016, 129 (08) : 903 - 908
  • [39] Desmoplastic fibroma in a child: a 9-year follow-up case report
    Lu, Yaokai
    Lan, Wei
    Wu, Qiangchu
    Fu, Yi
    Lan, Shengyuan
    Wang, Xixiong
    Huang, Xuwei
    Ye, Lu
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [40] Ten-year follow-up of the non-porous Allofit cementless acetabular component
    Zenz, P.
    Stiehl, J. B.
    Knechtel, H.
    Titzer-Hochmaier, G.
    Schwagerl, W.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2009, 91B (11): : 1443 - 1447