Revision of failed acetabular components utilizing a cementless oblong cup: an average 9-year follow-up study

被引:14
|
作者
Koester, Georg [1 ]
Rading, Sabine [1 ]
机构
[1] Chirurg Orthopad Fachklin Lorsch, Abt Orthopad Chirurg & Traumatol, D-64653 Lorsch, Germany
关键词
Hip; Revision; Acetabular defects; Oblong cup; Long-term results; TOTAL HIP-ARTHROPLASTY; REINFORCEMENT RING; RECONSTRUCTION; REPLACEMENT; ALLOGRAFTS; FAILURE; DEFECTS; 5-YEAR; SURGERY;
D O I
10.1007/s00402-008-0624-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Failure of acetabular components often leads to bone loss with extensive elongated defects in the surrounding bone. In these cases, reconstruction is challenging and stable fixation of the revision implant difficult. The use of an oblong cup has been described as an option for acetabular reconstruction in such revisions. We report the first long-term results obtained with this implant to date. Fifty-six longitudinal oblong revision cups (LOR (TM)) were evaluated clinically and radiologically after a follow-up of 8-12 years (average 9 years). The defects treated with the LOR (TM) cup ranged from Paprosky type 1-3. Allogenic cancellous bone chips were additionally used in 31 reconstructions to fill cavitary defects. Based on radiological criteria, 50 acetabular implants underwent osseointegration without any definitive signs of loosening; 2 consistently exhibited zonal radiolucent lines that were always smaller than 2 mm, 1 migrated by around 3 mm. None of these cases exhibited any clinical symptoms. In 11 cases where acetabular defects manifested postoperatively, 8 were remodeled completely and 3 partially at final follow-up. Three revision implants migrated farther than 5 mm and had to be revised before 32-month follow-up. In addition, 1 septic implant failure occurred. After an average follow-up of 9 years, 93% of the investigated implants remained in situ without further revision and 95% without aseptic implant failure. This 12-year clinical study demonstrates that the LOR (TM) cup offers a successful concept for the revision of failed acetabular components that also promotes the biological reconstruction of bony defects. Compared with other methods with similarly long follow-ups, our long-term results prove this procedure has a very low rate of revision and aseptic implant failure.
引用
收藏
页码:603 / 608
页数:6
相关论文
共 50 条
  • [21] Results of cemented metal-backed acetabular components - A 10-year-average follow-up study
    Chen, FS
    Di Cesare, PE
    Kale, AA
    Lee, JF
    Frankel, VH
    Stuchin, SA
    Zuckerman, JD
    JOURNAL OF ARTHROPLASTY, 1998, 13 (08) : 867 - 873
  • [22] Revision total hip replacement with a cemented long femoral component: minimum 9-year follow-up results
    Kazutaka So
    Yutaka Kuroda
    Shuichi Matsuda
    Haruhiko Akiyama
    Archives of Orthopaedic and Trauma Surgery, 2013, 133 : 869 - 874
  • [23] Minimum 5-Year Follow-Up of a Cementless, Modular, Tapered Stem in Hip Revision Arthroplasty
    Weiss, Rudiger J.
    Beckman, Mats O.
    Enocson, Anders
    Schmalholz, Anders
    Stark, Andre
    JOURNAL OF ARTHROPLASTY, 2011, 26 (01) : 16 - 23
  • [24] Revision total hip replacement with a cemented long femoral component: minimum 9-year follow-up results
    So, Kazutaka
    Kuroda, Yutaka
    Matsuda, Shuichi
    Akiyama, Haruhiko
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2013, 133 (06) : 869 - 874
  • [25] Thirteen year follow-up of a cementless femoral stem and a threaded acetabular cup in patients younger than fifty years of age
    Jan Schmolders
    Grigoris Amvrazis
    Peter H. Pennekamp
    Andreas Christian Strauss
    Max Julian Friedrich
    Matthias D. Wimmer
    Yorck Rommelspacher
    Dieter Christian Wirtz
    Thomas Wallny
    International Orthopaedics, 2017, 41 : 39 - 45
  • [26] Thirteen year follow-up of a cementless femoral stem and a threaded acetabular cup in patients younger than fifty years of age
    Schmolders, Jan
    Amvrazis, Grigoris
    Pennekamp, Peter H.
    Strauss, Andreas Christian
    Friedrich, Max Julian
    Wimmer, Matthias D.
    Rommelspacher, Yorck
    Wirtz, Dieter Christian
    Wallny, Thomas
    INTERNATIONAL ORTHOPAEDICS, 2017, 41 (01) : 39 - 45
  • [27] Custom Triflange Acetabular Components for Large Acetabular Defects: Minimum 10-Year Follow-up
    Moore, K. David
    McClenny, Michelle D.
    Wills, Bradley W.
    ORTHOPEDICS, 2018, 41 (03) : E316 - E320
  • [28] Medial Protrusio Technique in Cementless Total Hip Arthroplasty for Developmental Dysplasia of the Hip: A Prospective 6- to 9-Year Follow-Up of 43 Consecutive Patients
    Zha, Guo-Chun
    Sun, Jun-Ying
    Guo, Kai-Jin
    Zhao, Feng-Chao
    Pang, Yong
    Zheng, Xin
    JOURNAL OF ARTHROPLASTY, 2016, 31 (08) : 1761 - 1766
  • [29] Thigh pain, subsidence and survival using a short cementless femoral stem with pure metaphyseal fixation at minimum 9-year follow-up
    Cinotti, G.
    Della Rocca, A.
    Sessa, P.
    Ripani, F. R.
    Giannicola, G.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2013, 99 (01) : 30 - 36
  • [30] Results of the cementless Plasmacup in revision total hip arthroplasty: a retrospective study of 72 cases with an average follow-up of eight years
    Lakemeier, Stefan
    Aurand, Guenter
    Timmesfeld, Nina
    Heyse, Thomas J.
    Fuchs-Winkelmann, Susanne
    Schofer, Markus D.
    BMC MUSCULOSKELETAL DISORDERS, 2010, 11