Revision of failed acetabular components utilizing a cementless oblong cup: an average 9-year follow-up study

被引:14
|
作者
Koester, Georg [1 ]
Rading, Sabine [1 ]
机构
[1] Chirurg Orthopad Fachklin Lorsch, Abt Orthopad Chirurg & Traumatol, D-64653 Lorsch, Germany
关键词
Hip; Revision; Acetabular defects; Oblong cup; Long-term results; TOTAL HIP-ARTHROPLASTY; REINFORCEMENT RING; RECONSTRUCTION; REPLACEMENT; ALLOGRAFTS; FAILURE; DEFECTS; 5-YEAR; SURGERY;
D O I
10.1007/s00402-008-0624-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Failure of acetabular components often leads to bone loss with extensive elongated defects in the surrounding bone. In these cases, reconstruction is challenging and stable fixation of the revision implant difficult. The use of an oblong cup has been described as an option for acetabular reconstruction in such revisions. We report the first long-term results obtained with this implant to date. Fifty-six longitudinal oblong revision cups (LOR (TM)) were evaluated clinically and radiologically after a follow-up of 8-12 years (average 9 years). The defects treated with the LOR (TM) cup ranged from Paprosky type 1-3. Allogenic cancellous bone chips were additionally used in 31 reconstructions to fill cavitary defects. Based on radiological criteria, 50 acetabular implants underwent osseointegration without any definitive signs of loosening; 2 consistently exhibited zonal radiolucent lines that were always smaller than 2 mm, 1 migrated by around 3 mm. None of these cases exhibited any clinical symptoms. In 11 cases where acetabular defects manifested postoperatively, 8 were remodeled completely and 3 partially at final follow-up. Three revision implants migrated farther than 5 mm and had to be revised before 32-month follow-up. In addition, 1 septic implant failure occurred. After an average follow-up of 9 years, 93% of the investigated implants remained in situ without further revision and 95% without aseptic implant failure. This 12-year clinical study demonstrates that the LOR (TM) cup offers a successful concept for the revision of failed acetabular components that also promotes the biological reconstruction of bony defects. Compared with other methods with similarly long follow-ups, our long-term results prove this procedure has a very low rate of revision and aseptic implant failure.
引用
收藏
页码:603 / 608
页数:6
相关论文
共 50 条
  • [1] Revision of failed acetabular components utilizing a cementless oblong cup: an average 9-year follow-up study
    Georg Köster
    Sabine Rading
    Archives of Orthopaedic and Trauma Surgery, 2009, 129 : 603 - 608
  • [2] The use of morselized allografts without impaction and cemented cage support in acetabular revision surgery: a 4-to 9-year follow-up
    Ding, Huifeng
    Mao, Yuanqing
    Yu, Bin
    Zhu, Zhenan
    Li, Huiwu
    Yu, Baoqing
    Huang, Jianming
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2015, 10
  • [3] An oblong revision cup for large acetabular defects -: Design rationale and two- to seven-year follow-up
    Köster, G
    Willert, HG
    Köhler, HP
    Döpkens, K
    JOURNAL OF ARTHROPLASTY, 1998, 13 (05) : 559 - 569
  • [4] Revision of Failed Total Hip Arthroplasty Acetabular Cups to Porous Tantalum Components A 5-Year Follow-Up Study
    Fernandez-Fairen, Mariano
    Murcia, Antonio
    Blanco, Agustin
    Merono, Antonio
    Murcia, Antonio, Jr.
    Ballester, Jorge
    JOURNAL OF ARTHROPLASTY, 2010, 25 (06) : 865 - 872
  • [5] Modular acetabular reconstructive cup in acetabular revision total hip arthroplasty at a minimum ten year follow-up
    Sakai, Takashi
    Ohzono, Kenji
    Nishii, Takashi
    Takao, Masaki
    Miki, Hidenobu
    Nakamura, Nobuo
    Sugano, Nobuhiko
    INTERNATIONAL ORTHOPAEDICS, 2013, 37 (04) : 605 - 610
  • [6] Structural and Morselized Allografting Combined with a Cementless Cup for Acetabular Defects in Revision Total Hip Arthroplasty: A 4-to 14-Year Follow-Up
    Chen, Hou-Tsung
    Wu, Cheng-Ta
    Huang, Tsan-Wen
    Shih, Hsin-Nung
    Wang, Jun-Wen
    Lee, Mel S.
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [7] Acetabular Revision Total Hip Arthroplasty Using an Impacted Morselized Allograft and a Cementless Cup Minimum 10-Year Follow-Up
    Lee, Joong-Myung
    Nam, Hee-Tae
    JOURNAL OF ARTHROPLASTY, 2011, 26 (07) : 1057 - 1060
  • [8] Revision Total Hip Arthroplasty Using a Cementless Cup Supporter and Iliac Autograft: A Minimum of 15-Year Follow-Up
    Yoshino, Kensuke
    Tsukeoka, Tadashi
    Tsuneizumi, Yoshikazu
    Lee, Tae Hyun
    Nakamura, Junichi
    Suzuki, Masahiko
    Ohtori, Seiji
    JOURNAL OF ARTHROPLASTY, 2017, 32 (11) : 3495 - 3501
  • [9] The use of morselized allografts without impaction and cemented cage support in acetabular revision surgery: a 4- to 9-year follow-up
    Huifeng Ding
    Yuanqing Mao
    Bin Yu
    Zhenan Zhu
    Huiwu Li
    Baoqing Yu
    Jianming Huang
    Journal of Orthopaedic Surgery and Research, 10
  • [10] Acetabular revision surgery with the LOR cup: Three to 8 years' follow-up
    Surace, MF
    Zatti, G
    De Pietri, M
    Cherubino, P
    JOURNAL OF ARTHROPLASTY, 2006, 21 (01) : 114 - 121