Uncertainties of spectral in situ measurements in wastewater using different calibration approaches

被引:42
作者
Rieger, L.
Langergraber, G.
Siegrist, H.
机构
[1] Ecole Polytech, Dept CGM, Montreal, PQ H1V 1B3, Canada
[2] Univ Nat Resources & Appl Life Sci, Inst Sanitary Engn & Water Pollut Control, BOKU, A-1190 Vienna, Austria
[3] Swiss Fed Inst Environm Sci & Technol, EAWAG, CH-8600 Dubendorf, Switzerland
关键词
calibration; in situ sensor; uncertainty; UV/VIS spectroscopy;
D O I
10.2166/wst.2006.421
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Three calibration methods were applied to UV/VIS spectra recorded in the influent of six wastewater treatment plants (WWTPs) to measure total COD (CODtot), filtered COD (CODfil), nitrate and nitrite nitrogen (NOx-N) and total suspended solids (TSS). It could be shown that a calibration of the sensor using data sets from four Swiss WWTPs leads to an improvement of the precision in comparison to the global calibration provided by the manufacturer. A calibration to the specific wastewater matrix always improves the results and gives the highest accuracy. For CODtot a mean coefficient of variation CVx of 12.5% could be reached, whereas for NOx-N only weak results were achieved (average CVx = 36%).
引用
收藏
页码:187 / 197
页数:11
相关论文
共 50 条
  • [31] Assessing measurement uncertainty in CMM measurements: Comparison of different approaches
    Ruffa, S.
    Panciani, G.D.
    Ricci, F.
    Vicario, G.
    Ruffa, S. (suela.ruffa@polito.it), 1600, EDP Sciences (04): : 163 - 168
  • [32] Verifying Aquarius Radiometer Calibration Drift Using In Situ Data
    Lagerloef, Gary
    Carey, David
    Kao, Hsun-Ying
    2018 IEEE 15TH SPECIALIST MEETING ON MICROWAVE RADIOMETRY AND REMOTE SENSING OF THE ENVIRONMENT (MICRORAD), 2018, : 139 - 142
  • [33] A perforated heat flux plate for building measurements: calibration, in-situ performance and simulation
    Malagoli, M.
    Gallego, S.
    Proquez, V.
    Ginestet, S.
    Escadeillas, G.
    ENERGY AND BUILDINGS, 2023, 284
  • [34] Monte Carlo based calibration of scintillation detectors for laboratory and in situ gamma ray measurements
    van der Graaf, E. R.
    Limburg, J.
    Koomans, R. L.
    Tijs, M.
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2011, 102 (03) : 270 - 282
  • [35] Different approaches for calibration of an operational water distribution system containing old pipes
    Annus, Ivar
    Vassiljev, Anatoli
    COMPUTING AND CONTROL FOR THE WATER INDUSTRY (CCWI2015): SHARING THE BEST PRACTICE IN WATER MANAGEMENT, 2015, 119 : 526 - 534
  • [36] Assessment of MODIS and VIIRS Calibration Consistency for Reflective Solar Bands Calibration Using Vicarious Approaches
    Wu, A.
    Mu, Q.
    Angal, A.
    Xiong, X.
    SENSORS, SYSTEMS, AND NEXT-GENERATION SATELLITES XXIV, 2020, 11530
  • [37] Calibration problems for dimensional measurements of microvessel using TV methods
    Hu, Q
    Mahler, F
    Ouanella, M
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1997, 17 (02): : 97 - 97
  • [38] Field Calibration of Weirs Using Partial Volumetric Flow Measurements
    Soulis, Konstantinos X.
    Dercas, Nicholas
    JOURNAL OF IRRIGATION AND DRAINAGE ENGINEERING, 2012, 138 (05) : 481 - 484
  • [39] Radiometer Calibration Using Colocated GPS Radio Occultation Measurements
    Blackwell, William J.
    Bishop, Rebecca
    Cahoy, Kerri
    Cohen, Brian
    Crail, Clayton
    Cucurull, Lidia
    Dave, Pratik
    DiLiberto, Michael
    Erickson, Neal
    Fish, Chad
    Ho, Shu-peng
    Leslie, R. Vincent
    Milstein, Adam B.
    Osaretin, Idahosa A.
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2014, 52 (10): : 6423 - 6433
  • [40] DETERMINATION OF CALIBRATION COEFFICIENT FOR RADON MEASUREMENTS USING A TRACK DETECTOR
    NIKEZIC, D
    MARKOVIC, P
    BEKUZAROV, D
    HEALTH PHYSICS, 1993, 64 (06): : 628 - 632