On the passive and semiconducting behavior of severely deformed pure titanium in Ringer's physiological solution at 37 °C: A trial of the point defect model

被引:41
作者
Ansari, Ghazaleh [1 ]
Fattah-alhosseini, Arash [1 ]
机构
[1] Bu Ali Sina Univ, Dept Mat Engn, Hamadan 6517S38695, Iran
来源
MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS | 2017年 / 75卷
关键词
Titanium; Ringer's physiological solution; Nano-grained; PDM; Mott-Schottky; NI-BASED SUPERALLOY; CORROSION BEHAVIOR; OXIDE-FILMS; MECHANICAL-PROPERTIES; ELECTROCHEMICAL CORROSION; GRAIN-SIZE; ALLOYS; TI; RESISTANCE; NANOCRYSTALLIZATION;
D O I
10.1016/j.msec.2017.02.046
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
The effects of sever plastic deformation through multi-pass accumulative roll bonding on the passive and semiconducting behavior of pure titanium is evaluated in Ringer's physiological solution at 37 in the present paper. Produced results by polarization plots and electrochemical impedance spectroscopy measurements revealed a significant advance in the passive response of the nano-grained sample compared to that of the annealed pure titanium. Also, Mott-Schottky test results of the nano-grained pure titanium represented a lower donor density and reduced flat-band potential in the formed passive film in comparison with the annealed sample. Moreover, based on the Mott-Schottky analysis in conjunction with the point defect model, it was suggested that with increase in formation potential, the calculated donor density of both annealed and nano-grained samples decreases exponentially and the thickness of the passive film linearly increases. These observations were consistent with the point defect model predictions, considering that the point defects within the passive film are metal interstitials, oxygen vacancies, or both. From the viewpoint of passive and semiconducting behavior, nano-grained pure titanium appeared to be more suitable for implant applications in simulate human body environment compared to annealed pure titanium. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:64 / 71
页数:8
相关论文
共 59 条
[41]   Comparison of metal release from various metallic biomaterials in vitro [J].
Okazaki, Y ;
Gotoh, E .
BIOMATERIALS, 2005, 26 (01) :11-21
[42]   Electrochemical stability and corrosion resistance of Ti-Mo alloys for biomedical applications [J].
Oliveira, N. T. C. ;
Guastaldi, A. C. .
ACTA BIOMATERIALIA, 2009, 5 (01) :399-405
[43]  
Park J., 2007, BIOMATERIALS
[44]   Effect of oxygen vacancies in anodic titanium oxide films on the kinetics of the oxygen electrode reaction [J].
Roh, B. ;
Macdonald, D. D. .
RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2007, 43 (02) :125-135
[45]   Novel ultra-high straining process for bulk materials - Development of the accumulative roll-bonding (ARB) process [J].
Saito, Y ;
Utsunomiya, H ;
Tsuji, N ;
Sakai, T .
ACTA MATERIALIA, 1999, 47 (02) :579-583
[46]   Understanding the effect of bromides on the stability of titanium oxide films based on a point defect model [J].
Sazou, Dimitra ;
Saltidou, Kyriaki ;
Pagitsas, Michael .
ELECTROCHIMICA ACTA, 2012, 76 :48-61
[47]   Measurement method for carrier concentration in TiO2 via the Mott-Schottky approach [J].
Sellers, Meredith C. K. ;
Seebauer, Edmund G. .
THIN SOLID FILMS, 2011, 519 (07) :2103-2110
[48]   A new method for estimating the diffusivities of vacancies in passive films [J].
Sikora, E ;
Sikora, J ;
MacDonald, DD .
ELECTROCHIMICA ACTA, 1996, 41 (06) :783-789
[49]  
Smialowska S., 1983, PASSIVITY METALS SEM
[50]   Microstructure and mechanical properties of commercial purity titanium severely deformed by ARB process [J].
Terada, Daisuke ;
Inoue, Seiya ;
Tsuji, Nobuhiro .
JOURNAL OF MATERIALS SCIENCE, 2007, 42 (05) :1673-1681