Comparison between high-resolution MRI with a microscopy coil and arthroscopy in triangular fibrocartilage complex injury

被引:66
作者
Tanaka, Toshikazu
Yoshioka, Hiroshi
Ueno, Teruko
Shindo, Masashi
Ochiai, Naoyuki
机构
[1] Tsukuba Mem Hosp, Dept Orthoped Surg, Tsukuba, Ibaraki, Japan
[2] Univ Tsukuba, Dept Radiol, Tsukuba, Ibaraki 305, Japan
[3] Univ Tsukuba, Dept Orthoped Surg, Tsukuba, Ibaraki 305, Japan
[4] Univ Hosp, Dept Radiol, Tsukuba, Ibaraki, Japan
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2006年 / 31A卷 / 08期
关键词
triangular fibrocartilage complex (TFCC); magnetic resonance imaging (MRI); microscopy coil; arthroscopy; diagnosis;
D O I
10.1016/j.jhsa.2006.05.001
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: To determine whether high-resolution magnetic resonance imaging (MRI) could detect injuries to the triangular fibrocartilage complex (TFCC). Methods: Eleven patients who showed both a positive sign during the ulnocarpal stress test and tenderness at the distal end of the ulna had a high-resolution MRI using a 47-mm diameter microscopy coil. Six regions of the TFCC were investigated for injury: the radial attachment, disc, ulnar attachment of the triangular fibrocartilage (TFC), ulnotriquetral ligament, palmar radioulnar ligament (PRUL), and dorsal radioulnar ligament (DRUL). Arthroscopy was performed subsequently on each patient. Results: For injuries to the radial attachment or the disc of the TFC, a high-resolution MRI showed 100% sensitivity and 100% specificity compared with arthroscopy. In 3 cases in which injury to the ulnar attachment of the TFC was detected with MRI and examination showed a positive piano-key sign and distal radioulnar joint instability, only 1 injury was confirmed with arthrotomy. For MRI diagnosis of an ulnotriquetral ulnolunate attachment injury, the sensitivity was 100% and the specificity was 70%; however, 3 cases had false-positive results. Finally MRI had 100% sensitivity for detecting DRUL and PRUL injuries, although specificities were 75% and 83%, respectively. With MRI there were 2 false-positive DRUL injury diagnoses and 1 false-positive PRUL injury diagnosis. Conclusions: High-resolution MRI using a microscopy surface coil allowed assessment of each TFCC component and showed a higher accuracy for diagnosing injuries to the radial attachment and the disc of the TFC compared with previous studies. High-resolution MRI, however, was not able to diagnose DRUL, PRUL, or ulnolunate ligament injuries accurately.
引用
收藏
页码:1308 / 1314
页数:7
相关论文
共 26 条
[1]   In vivo high resolution coronal MRI of the wrist at 8.0 tesla [J].
Ashman, CJ ;
Farooki, S ;
Abduljalil, AM ;
Chakeres, DW .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2002, 26 (03) :387-391
[2]   Complications of wrist arthroscopy [J].
Beredjiklian, PK ;
Bozentka, DJ ;
Leung, YL ;
Monaghan, BA .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2004, 29A (03) :406-411
[3]  
Berger RA, 1999, HAND CLIN, V15, P393
[4]   The effect of observer experience on magnetic resonance imaging interpretation and localization of triangular fibrocartilage complex lesions [J].
Blazar, PE ;
Chan, PSH ;
Kneeland, JB ;
Leatherwood, D ;
Bozentka, DJ ;
Kowalchick, R .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2001, 26A (04) :742-748
[5]  
Chen ACY, 2005, ARTHROSCOPY, V21, P1406, DOI 10.1016/j.arthro.2005.07.016
[6]  
Dailey SW, 2000, HAND CLIN, V16, P461
[7]  
Hagert C G, 1994, Handchir Mikrochir Plast Chir, V26, P22
[8]   Internal derangement of the wrist: Indirect MR arthrography versus unenhanced MR imaging [J].
Haims, AH ;
Schweitzer, ME ;
Morrison, WB ;
Deely, D ;
Lange, RC ;
Osterman, AL ;
Bednar, JM ;
Taras, JS ;
Culp, RW .
RADIOLOGY, 2003, 227 (03) :701-707
[9]   Limitations of MR Imaging in the diagnosis of peripheral tears of the triangular fibrocartilage of the wrist [J].
Haims, AH ;
Schweitzer, ME ;
Morrison, WB ;
Deely, D ;
Lange, R ;
Osterman, AL ;
Bednar, JM ;
Taras, JS ;
Culp, RW .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 178 (02) :419-422
[10]   MR imaging of the wrist: Effect on clinical diagnosis and patient care [J].
Hobby, JL ;
Dixon, AK ;
Bearcroft, PWP ;
Tom, BDM ;
Lomas, DJ ;
Rushton, N ;
Matthewson, MH .
RADIOLOGY, 2001, 220 (03) :589-593