Denoising of HD-sEMG signals using canonical correlation analysis

被引:33
作者
Al Harrach, M. [1 ]
Boudaoud, S. [1 ]
Hassan, M. [2 ]
Ayachi, F. S. [3 ]
Gamet, D. [1 ]
Grosset, J. F. [1 ]
Marin, F. [1 ]
机构
[1] Univ Technol Compiegne, Sorbonne Univ, CNRS, UMR 7338, Compiegne, France
[2] Univ Rennes 1, F-35000 Rennes, France
[3] Inst Univ Geriatrie Montreal, Montreal, PQ, Canada
关键词
HD-sEMG; Denoising; Blind source separation; Canonical correlation analysis; Thresholding; Channel selection; SURFACE EMG; MOTOR UNITS; DECOMPOSITION; NOISE; CCA;
D O I
10.1007/s11517-016-1521-x
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
High-density surface electromyography (HD-sEMG) is a recent technique that overcomes the limitations of monopolar and bipolar sEMG recordings and enables the collection of physiological and topographical informations concerning muscle activation. However, HD-sEMG channels are usually contaminated by noise in an heterogeneous manner. The sources of noise are mainly power line interference (PLI), white Gaussian noise (WGN) and motion artifacts (MA). The spectral components of these disruptive signals overlap with the sEMG spectrum which makes classical filtering techniques non effective, especially during low contraction level recordings. In this study, we propose to denoise HD-sEMG recordings at 20 % of the maximum voluntary contraction by using a second-order blind source separation technique, named canonical component analysis (CCA). For this purpose, a specific and automatic canonical component selection, using noise ratio thresholding, and a channel selection procedure for the selective version (sCCA) are proposed. Results obtained from the application of the proposed methods (CCA and sCCA) on realistic simulated data demonstrated the ability of the proposed approach to retrieve the original HD-sEMG signals, by suppressing the PLI and WGN components, with high accuracy (for five different simulated noise dispersions using the same anatomy). Afterward, the proposed algorithms are employed to denoise experimental HD-sEMG signals from five healthy subjects during biceps brachii contractions following an isometric protocol. Obtained results showed that PLI and WGN components could be successfully removed, which enhances considerably the SNR of the channels with low SNR and thereby increases the mean SNR value among the grid. Moreover, the MA component is often isolated on specific estimated sources but requires additional signal processing for a total removal. In addition, comparative study with independent component analysis, CCA-wavelet and CCA-empirical mode decomposition (EMD) proved a higher efficiency of the presented method over existing denoising techniques and demonstrated pointless a second filtering stage for denoising HD-sEMG recordings at this contraction level.
引用
收藏
页码:375 / 388
页数:14
相关论文
共 28 条
[1]  
Agante PM, 1999, COMPUT CARDIOL, V1999, P353
[2]  
Al Harrach M, 2014, IEEE ENG MED BIO, P2209, DOI 10.1109/EMBC.2014.6944057
[3]  
Allouch S, 2013, I CON ADV BIOMED ENG, P195, DOI 10.1109/ICABME.2013.6648881
[4]   EMG signal filtering based on Empirical Mode Decomposition [J].
Andrade, Adriano O. ;
Nasuto, Slawomir ;
Kyberd, Peter ;
Sweeney-Reed, Catherine M. ;
Van Kanijn, F. R. .
BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2006, 1 (01) :44-55
[5]   Denoising of surface EMG with a modified Wiener filtering approach [J].
Aschero, Giovanni ;
Gizdulich, Paolo .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2010, 20 (02) :366-373
[6]   Evaluation of muscle force classification using shape analysis of the sEMG probability density function: a simulation study [J].
Ayachi, F. S. ;
Boudaoud, S. ;
Marque, C. .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2014, 52 (08) :673-684
[7]   Methods to reduce the variability of EMG power spectrum estimates [J].
Baratta, RV ;
Solomonow, M ;
Zhou, BH ;
Zhu, M .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 1998, 8 (05) :279-285
[8]   Sampling, noise-reduction and amplitude estimation issues in surface electromyography [J].
Clancy, EA ;
Morin, EL ;
Merletti, R .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2002, 12 (01) :1-16
[9]   Canonical correlation analysis applied to remove muscle artifacts from the electroencephalogram [J].
De Clercq, Wim ;
Vergult, Anneleen ;
Vanrumste, Bart ;
Van Paesschen, Wim ;
Van Huffel, Sabine .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2006, 53 (12) :2583-2587
[10]   Hierarchical control of motor units in voluntary contractions [J].
De Luca, Carlo J. ;
Contessa, Paola .
JOURNAL OF NEUROPHYSIOLOGY, 2012, 107 (01) :178-195