A Computational Technique to Evaluate the Relative Influence of Internal and External Cooling on Overall Effectiveness

被引:27
作者
Bryant, Carol E. [1 ]
Rutledge, James L. [2 ]
机构
[1] US Air Force, Res Lab, Wright Patterson AFB, OH 45433 USA
[2] US Air Force, Inst Technol, Wright Patterson AFB, OH 45433 USA
来源
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME | 2020年 / 142卷 / 05期
关键词
computational fluid dynamics (CFD); fluid dynamics and heat transfer phenomena in compressor and turbine components of gas turbine engines; heat transfer and film cooling;
D O I
10.1115/1.4045987
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Gas turbine components are protected via a coolant that travels through internal passageways before being ejected as external film cooling. Modern computational approaches facilitate the simulation of the conjugate heat transfer that takes place within turbine components, allowing the prediction of the actual metal temperature, nondimensionalized as overall effectiveness. Efforts aimed at improving cooling are often focused on either the internal cooling or the film cooling; however, the common coolant flow means that the internal and external cooling schemes are linked and the coolant holes themselves provide another convective path for heat transfer to the coolant. The relative influence of internal cooling, external cooling, and convection through the film cooling holes on overall effectiveness is not well understood. Computational fluid dynamics (CFD) simulations were performed to isolate each cooling mechanism, and thereby determine their relative contributions to overall effectiveness. The conjugate CFD model was a flat plate with five staggered rows of shaped film cooling holes. Unique boundary conditions were used to isolate the cooling mechanisms. The internal surface was modeled with and without heat transfer on the internal face in order to isolate the effects of plenum cooling. Convection through the coolant holes was isolated by making the inside of the film cooling holes adiabatic to evaluate the influence of the internal cooling provided by the cooling holes themselves. Finally, the effect of film cooling was removed through the novel use of an outlet boundary condition at the exit of each hole that allowed the internal coolant flow without external coolant ejection.
引用
收藏
页数:11
相关论文
共 14 条
[1]  
Albert J.E., 2004, ASME Turbo Expo 2004: Power for Land, Sea, DOI DOI 10.1115/GT2013-94928
[2]   Experimental Evaluations of the Relative Contributions to Overall Effectiveness in Turbine Blade Leading Edge Cooling [J].
Bryant, Carol E. ;
Wiese, Connor J. ;
Rutledge, James L. ;
Polanka, Marc D. .
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2019, 141 (04)
[3]  
CHAVEZ K, 2016, P ASM TURB EXP TURB
[4]  
Dyson TE, 2013, PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2013, VOL 3B
[5]  
Fischer JP, 2019, PROCEEDINGS OF THE ASME TURBO EXPO: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, 2019, VOL 5A
[6]   Experimental and Numerical Investigation of Sweeping Jet Film Cooling [J].
Hossain, Mohammad A. ;
Prenter, Robin ;
Lundgreen, Ryan K. ;
Ameri, Ali ;
Gregory, James W. ;
Bons, Jeffrey P. .
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2018, 140 (03)
[7]  
Mensch A, 2013, PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2013, VOL 3B
[8]  
Ravelli S, 2010, PROCEEDINGS OF THE ASME TURBO EXPO 2010, VOL 4, PTS A AND B, P1655
[9]  
RUTLEDGE J, 2014, P ASME TURB EXP, V136
[10]   The Delta Phi Method of Evaluating Overall Film Cooling Performance [J].
Rutledge, James L. ;
Polanka, Marc D. ;
Bogard, David G. .
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2016, 138 (07)