Effect of bone density on the damping behavior of dental implants: An in vitro method

被引:32
|
作者
VanSchoiack, Lindsey R.
Wu, Jean C.
Sheets, Cherilyn G.
Earthman, James C.
机构
[1] Univ Calif Irvine, Dept Biomed Engn, Irvine, CA 92697 USA
[2] Newport Coast Oral Facial Inst, Dept Biomed Engn, Newport Beach, CA USA
[3] Univ Calif Irvine, Dept Chem Engn & Mat Sci, Irvine, CA 92697 USA
来源
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS | 2006年 / 26卷 / 08期
关键词
osseointegration; loss coefficient; dental implants; bone density;
D O I
10.1016/j.msec.2005.08.019
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
For normal healthy teeth the percussive energy generated by mastication is attenuated by the periodontal ligament at the healthy bone-natural tooth interface. However when the natural tooth must be replaced by an implant due to damage or disease the ligament is lost and the implant will transmit the percussive forces directly into the bone. Studies have been carried out to examine the mechanical damping behavior of dental implants. However, a study of the effect of bone density at the time of implant placement in conjunction with quantitative measures of mechanical energy dissipation has not been reported. The present research hopes to uncover some of this missing information by evaluating the effect of bone density on the energy dissipation of an implant upon surgical placement. In this work, four different dental implant geometries were tested as a function of simulated bone density utilizing a series of artificial foam bone models (Pacific Research Laboratories, Vashon Island, WA) that vary in density and structure. The implants were placed following recommended placement protocols. The hypothesis of the work is that the Periometer, a percussion probe system designed to measure local damping capacity, can be used to assess the quality of the underlying support structure. It is also hypothesized that Periometer results can be used to differentiate between implant model geometries within the same support structures. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:1307 / 1311
页数:5
相关论文
共 50 条
  • [41] Effect of crown to implant ratio and implantoplasty on the fracture resistance of narrow dental implants with marginal bone loss: an in vitro study
    Leitao-Almeida, Bruno
    Camps-Font, Octavi
    Correia, Andre
    Mir-Mari, Javier
    Figueiredo, Rui
    Valmaseda-Castellon, Eduard
    BMC ORAL HEALTH, 2020, 20 (01)
  • [42] Effect of crown to implant ratio and implantoplasty on the fracture resistance of narrow dental implants with marginal bone loss: an in vitro study
    Bruno Leitão-Almeida
    Octavi Camps-Font
    André Correia
    Javier Mir-Mari
    Rui Figueiredo
    Eduard Valmaseda-Castellón
    BMC Oral Health, 20
  • [43] Osteocyte Density in the Peri-Implant Bone of Immediately Loaded and Submerged Dental Implants
    Barros, Raquel R. M.
    Degidi, Marco
    Novaes, Arthur B., Jr.
    Piattelli, Adriano
    Shibli, Jamil A.
    Iezzi, Giovanna
    JOURNAL OF PERIODONTOLOGY, 2009, 80 (03) : 499 - 504
  • [44] Reliability of Grayscale Value for Bone Density Determination in Oral Rehabilitation using Dental Implants
    Rai, Shalu
    Misra, Deepankar
    Misra, Akansha
    Tomar, Himanshi
    Dhawan, Ayush
    Gupta, Rohit
    INTERNATIONAL JOURNAL OF APPLIED AND BASIC MEDICAL RESEARCH, 2023, 13 (03) : 143 - 148
  • [45] Effect of macrogeometry and bone type on insertion torque, primary stability, surface topography damage and titanium release of dental implants during surgical insertion into artificial bone
    Ferreira Silva, Gabrielle Alencar
    Faot, Fernanda
    da Rosa Possebon, Anna Paula
    da Silva, Wander Jose
    Del Bel Cury, Altair Antoninha
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2021, 119
  • [46] Bone level around dental implants adjacent to teeth and implants
    Jairo Gomez-Guzman, John
    Marcela Arias-Holguin, Yohana
    Isabel Perez, Maria
    Augusto Restrepo-Restrepo, Felipe
    Rodriguez-Medina, Carolina
    Enrique Botero, Javier
    UNICIENCIA, 2022, 36 (01)
  • [47] Effect of Macrogeometry on the Surface Topography of Dental Implants
    Naves, Marina Melo
    Machado Menezes, Helder Henrique
    Magalhaes, Denildo
    Ferreira, Jessica Afonso
    Ribeiro, Sara Ferreira
    Biasoli de Mello, Jose Daniel
    Costa, Henara Lillian
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2015, 30 (04) : 789 - 799
  • [48] Bone autografts & allografts placed simultaneously with dental implants in rabbits
    Ribeiro, Marna
    Fraguas, Erica Hohlenwerger
    Brito, Keila Ilse Cangussu
    Kim, Yeon Jung
    Pallos, Debora
    Sendyk, Wilson Roberto
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2018, 46 (01) : 142 - 147
  • [49] A RADIOGRAPHIC-BASED METHOD FOR MARGINAL BONE LOSS MEASUREMENT IN DENTAL IMPLANTS
    Veronese, Elisa
    Veronese, Mattia
    Sivolella, Stefano
    Grisan, Enrico
    2013 IEEE 10TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2013, : 129 - 132
  • [50] Influence of cortical bone anchorage on the primary stability of dental implants
    de Oliveira Nicolau Mantovani A.K.
    de Mattias Sartori I.A.
    Azevedo-Alanis L.R.
    Tiossi R.
    Fontão F.N.G.K.
    Oral and Maxillofacial Surgery, 2018, 22 (3) : 297 - 301