Effect of bone density on the damping behavior of dental implants: An in vitro method
被引:32
|
作者:
VanSchoiack, Lindsey R.
论文数: 0引用数: 0
h-index: 0
机构:Univ Calif Irvine, Dept Biomed Engn, Irvine, CA 92697 USA
VanSchoiack, Lindsey R.
Wu, Jean C.
论文数: 0引用数: 0
h-index: 0
机构:Univ Calif Irvine, Dept Biomed Engn, Irvine, CA 92697 USA
Wu, Jean C.
Sheets, Cherilyn G.
论文数: 0引用数: 0
h-index: 0
机构:Univ Calif Irvine, Dept Biomed Engn, Irvine, CA 92697 USA
Sheets, Cherilyn G.
Earthman, James C.
论文数: 0引用数: 0
h-index: 0
机构:Univ Calif Irvine, Dept Biomed Engn, Irvine, CA 92697 USA
Earthman, James C.
机构:
[1] Univ Calif Irvine, Dept Biomed Engn, Irvine, CA 92697 USA
[2] Newport Coast Oral Facial Inst, Dept Biomed Engn, Newport Beach, CA USA
[3] Univ Calif Irvine, Dept Chem Engn & Mat Sci, Irvine, CA 92697 USA
来源:
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS
|
2006年
/
26卷
/
08期
关键词:
osseointegration;
loss coefficient;
dental implants;
bone density;
D O I:
10.1016/j.msec.2005.08.019
中图分类号:
T [工业技术];
学科分类号:
08 ;
摘要:
For normal healthy teeth the percussive energy generated by mastication is attenuated by the periodontal ligament at the healthy bone-natural tooth interface. However when the natural tooth must be replaced by an implant due to damage or disease the ligament is lost and the implant will transmit the percussive forces directly into the bone. Studies have been carried out to examine the mechanical damping behavior of dental implants. However, a study of the effect of bone density at the time of implant placement in conjunction with quantitative measures of mechanical energy dissipation has not been reported. The present research hopes to uncover some of this missing information by evaluating the effect of bone density on the energy dissipation of an implant upon surgical placement. In this work, four different dental implant geometries were tested as a function of simulated bone density utilizing a series of artificial foam bone models (Pacific Research Laboratories, Vashon Island, WA) that vary in density and structure. The implants were placed following recommended placement protocols. The hypothesis of the work is that the Periometer, a percussion probe system designed to measure local damping capacity, can be used to assess the quality of the underlying support structure. It is also hypothesized that Periometer results can be used to differentiate between implant model geometries within the same support structures. (c) 2005 Elsevier B.V. All rights reserved.
机构:
Univ Catolica Portuguesa, Ctr Inter Disciplinary Res Hlth CIIS, Fac Med Dent, Estr Circunvalacao, P-3504505 Viseu, PortugalUniv Catolica Portuguesa, Ctr Inter Disciplinary Res Hlth CIIS, Fac Med Dent, Estr Circunvalacao, P-3504505 Viseu, Portugal
Leitao-Almeida, Bruno
Camps-Font, Octavi
论文数: 0引用数: 0
h-index: 0
机构:
Univ Barcelona, Fac Med & Hlth Sci, Oral Surg & Implantol, Barcelona, SpainUniv Catolica Portuguesa, Ctr Inter Disciplinary Res Hlth CIIS, Fac Med Dent, Estr Circunvalacao, P-3504505 Viseu, Portugal
Camps-Font, Octavi
Correia, Andre
论文数: 0引用数: 0
h-index: 0
机构:
Univ Catolica Portuguesa, Ctr Inter Disciplinary Res Hlth CIIS, Fac Med Dent, Estr Circunvalacao, P-3504505 Viseu, PortugalUniv Catolica Portuguesa, Ctr Inter Disciplinary Res Hlth CIIS, Fac Med Dent, Estr Circunvalacao, P-3504505 Viseu, Portugal
Correia, Andre
Mir-Mari, Javier
论文数: 0引用数: 0
h-index: 0
机构:
Univ Barcelona, Fac Med & Hlth Sci, Oral Surg & Implantol, Barcelona, SpainUniv Catolica Portuguesa, Ctr Inter Disciplinary Res Hlth CIIS, Fac Med Dent, Estr Circunvalacao, P-3504505 Viseu, Portugal
Mir-Mari, Javier
Figueiredo, Rui
论文数: 0引用数: 0
h-index: 0
机构:
Univ Barcelona, Fac Med & Hlth Sci, Oral Surg & Implantol, Barcelona, SpainUniv Catolica Portuguesa, Ctr Inter Disciplinary Res Hlth CIIS, Fac Med Dent, Estr Circunvalacao, P-3504505 Viseu, Portugal
Figueiredo, Rui
Valmaseda-Castellon, Eduard
论文数: 0引用数: 0
h-index: 0
机构:
Univ Barcelona, Fac Med & Hlth Sci, Oral Surg & Implantol, Barcelona, SpainUniv Catolica Portuguesa, Ctr Inter Disciplinary Res Hlth CIIS, Fac Med Dent, Estr Circunvalacao, P-3504505 Viseu, Portugal
机构:
Latin American Institute for Dental Research and Education (ILAPEO), CuritibaLatin American Institute for Dental Research and Education (ILAPEO), Curitiba
de Oliveira Nicolau Mantovani A.K.
de Mattias Sartori I.A.
论文数: 0引用数: 0
h-index: 0
机构:
Latin American Institute for Dental Research and Education (ILAPEO), CuritibaLatin American Institute for Dental Research and Education (ILAPEO), Curitiba
de Mattias Sartori I.A.
Azevedo-Alanis L.R.
论文数: 0引用数: 0
h-index: 0
机构:
School of Dentistry, Pontifical Catholic University of Parana, CuritibaLatin American Institute for Dental Research and Education (ILAPEO), Curitiba
Azevedo-Alanis L.R.
Tiossi R.
论文数: 0引用数: 0
h-index: 0
机构:
Department of Restorative Dentistry, School of Dentistry, State University of Londrina (UEL), Rua Pernambuco, 540, Centro, LondrinaLatin American Institute for Dental Research and Education (ILAPEO), Curitiba
Tiossi R.
Fontão F.N.G.K.
论文数: 0引用数: 0
h-index: 0
机构:
Latin American Institute for Dental Research and Education (ILAPEO), CuritibaLatin American Institute for Dental Research and Education (ILAPEO), Curitiba