Effect of bone density on the damping behavior of dental implants: An in vitro method

被引:32
|
作者
VanSchoiack, Lindsey R.
Wu, Jean C.
Sheets, Cherilyn G.
Earthman, James C.
机构
[1] Univ Calif Irvine, Dept Biomed Engn, Irvine, CA 92697 USA
[2] Newport Coast Oral Facial Inst, Dept Biomed Engn, Newport Beach, CA USA
[3] Univ Calif Irvine, Dept Chem Engn & Mat Sci, Irvine, CA 92697 USA
来源
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS | 2006年 / 26卷 / 08期
关键词
osseointegration; loss coefficient; dental implants; bone density;
D O I
10.1016/j.msec.2005.08.019
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
For normal healthy teeth the percussive energy generated by mastication is attenuated by the periodontal ligament at the healthy bone-natural tooth interface. However when the natural tooth must be replaced by an implant due to damage or disease the ligament is lost and the implant will transmit the percussive forces directly into the bone. Studies have been carried out to examine the mechanical damping behavior of dental implants. However, a study of the effect of bone density at the time of implant placement in conjunction with quantitative measures of mechanical energy dissipation has not been reported. The present research hopes to uncover some of this missing information by evaluating the effect of bone density on the energy dissipation of an implant upon surgical placement. In this work, four different dental implant geometries were tested as a function of simulated bone density utilizing a series of artificial foam bone models (Pacific Research Laboratories, Vashon Island, WA) that vary in density and structure. The implants were placed following recommended placement protocols. The hypothesis of the work is that the Periometer, a percussion probe system designed to measure local damping capacity, can be used to assess the quality of the underlying support structure. It is also hypothesized that Periometer results can be used to differentiate between implant model geometries within the same support structures. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:1307 / 1311
页数:5
相关论文
共 50 条
  • [31] Effect of Oral Bacteria on the Mechanical Behavior of Titanium Dental Implants
    Javier Gil, Francisco
    Rodriguez, Ana
    Espinar, Eduardo
    Maria Llamas, Jose
    Padulles, Esteban
    Juarez, Antonio
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2012, 27 (01) : 64 - 68
  • [32] Wetting Behavior of Dental Implants
    Rupp, Frank
    Scheideler, Lutz
    Eichler, Mirjam
    Geis-Gerstorfer, Juergen
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (06) : 1256 - 1266
  • [33] Randomized Controlled Study on Effect of Concentrated Growth Factors on Crestal Bone Levels and Peri-implant Bone Density in Dental Implants
    Karthik, V. C.
    Prabhu, K.
    Bharath, N.
    Shobana, P.
    Indhu, K.
    Abraham, Sonia
    Arunalakshmi, K.
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2022, 14 : 68 - 77
  • [34] The Importance of Correlation between CBCT Analysis of Bone Density and Primary Stability When Choosing the Design of Dental Implants-Ex Vivo Study
    Mikic, Mirko
    Vlahovic, Zoran
    Stevanovic, Momir
    Arsic, Zoran
    Mladenovic, Rasa
    TOMOGRAPHY, 2022, 8 (03) : 1293 - 1306
  • [35] Relationship between the bone density estimated by cone-beam computed tomography and the primary stability of dental implants
    Isoda, Kei
    Ayukawa, Yasunori
    Tsukiyama, Yoshihiro
    Sogo, Motofumi
    Matsushita, Yasuyuki
    Koyano, Kiyoshi
    CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (07) : 832 - 836
  • [36] Effect of the Nature of the Particles Released from Bone Level Dental Implants: Physicochemical and Biological Characterization
    Vara, Juan Carlos
    Delgado, Juan
    Estrada-Martinez, Alejandro
    Perez-Pevida, Esteban
    Brizuela, Aritza
    Bosch, Begona
    Perez, Roman
    Gil, Javier
    COATINGS, 2022, 12 (02)
  • [37] The effect of hydroxyapatite nanocrystals on early bone formation surrounding dental implants
    Svanborg, L. M.
    Hoffman, M.
    Andersson, M.
    Currie, F.
    Kjellin, P.
    Wennerberg, A.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2011, 40 (03) : 308 - 315
  • [38] BONE-GRAFTING AND GUIDED BONE REGENERATION FOR IMMEDIATE DENTAL IMPLANTS IN HUMANS
    GHER, ME
    QUINTERO, G
    ASSAD, D
    MONACO, E
    RICHARDSON, AC
    JOURNAL OF PERIODONTOLOGY, 1994, 65 (09) : 881 - 891
  • [39] Effect of a Multiporous Beta-Tricalicum Phosphate on Bone Density Around Dental Implants Inserted Into Fresh Extraction Sockets
    Daif, Emad Tawfik
    JOURNAL OF ORAL IMPLANTOLOGY, 2013, 39 (03) : 339 - 344
  • [40] Electrotherapy for bone regeneration in dental implants
    Buzza, Edmur
    Olate, Sergio
    Pozzer, Leandro
    de Albergaria-Barbosa, Jose Ricardo
    INTERNATIONAL JOURNAL OF MORPHOLOGY, 2014, 32 (02): : 684 - 689