Effect of bone density on the damping behavior of dental implants: An in vitro method

被引:32
|
作者
VanSchoiack, Lindsey R.
Wu, Jean C.
Sheets, Cherilyn G.
Earthman, James C.
机构
[1] Univ Calif Irvine, Dept Biomed Engn, Irvine, CA 92697 USA
[2] Newport Coast Oral Facial Inst, Dept Biomed Engn, Newport Beach, CA USA
[3] Univ Calif Irvine, Dept Chem Engn & Mat Sci, Irvine, CA 92697 USA
来源
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS | 2006年 / 26卷 / 08期
关键词
osseointegration; loss coefficient; dental implants; bone density;
D O I
10.1016/j.msec.2005.08.019
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
For normal healthy teeth the percussive energy generated by mastication is attenuated by the periodontal ligament at the healthy bone-natural tooth interface. However when the natural tooth must be replaced by an implant due to damage or disease the ligament is lost and the implant will transmit the percussive forces directly into the bone. Studies have been carried out to examine the mechanical damping behavior of dental implants. However, a study of the effect of bone density at the time of implant placement in conjunction with quantitative measures of mechanical energy dissipation has not been reported. The present research hopes to uncover some of this missing information by evaluating the effect of bone density on the energy dissipation of an implant upon surgical placement. In this work, four different dental implant geometries were tested as a function of simulated bone density utilizing a series of artificial foam bone models (Pacific Research Laboratories, Vashon Island, WA) that vary in density and structure. The implants were placed following recommended placement protocols. The hypothesis of the work is that the Periometer, a percussion probe system designed to measure local damping capacity, can be used to assess the quality of the underlying support structure. It is also hypothesized that Periometer results can be used to differentiate between implant model geometries within the same support structures. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:1307 / 1311
页数:5
相关论文
共 50 条
  • [1] Effect of Photobiomodulation on Crestal Bone Density Around Dental Implants: A Case Report
    Singhania, Ashika
    Bhoyar, Anjali
    Dubey, Surekha A.
    Jaiswal, Tanvi
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (06)
  • [2] Damping factor for monitoring the bone interface at dental implants
    Veltri, Mario
    Balleri, Piero
    Ferrari, Marco
    CLINICAL ORAL IMPLANTS RESEARCH, 2007, 18 (06) : 738 - 742
  • [3] Biomaterials and Clinical Application of Dental Implants in Relation to Bone Density-A Narrative Review
    Khaohoen, Angkoon
    Sornsuwan, Tanapon
    Chaijareenont, Pisaisit
    Poovarodom, Pongsakorn
    Rungsiyakull, Chaiy
    Rungsiyakull, Pimduen
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (21)
  • [4] The Effect of Increasing Thread Depth on the Initial Stability of Dental Implants: An In Vitro Study
    Cucinelli, Chiara
    Pereira, Miguel Silva
    Borges, Tiago
    Figueiredo, Rui
    Leitao-Almeida, Bruno
    SURGERIES, 2024, 5 (03): : 817 - 825
  • [5] A method for segmentation of dental implants and crestal bone
    Cunha, Pedro
    Guevara, Miguel A.
    Messias, Ana
    Rocha, Salomao
    Reis, Rita
    Nicolau, Pedro M. G.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2013, 8 (05) : 711 - 721
  • [6] A method for segmentation of dental implants and crestal bone
    Pedro Cunha
    Miguel A. Guevara
    Ana Messias
    Salomão Rocha
    Rita Reis
    Pedro M. G. Nicolau
    International Journal of Computer Assisted Radiology and Surgery, 2013, 8 : 711 - 721
  • [7] Is there a lower threshold value of bone density for early loading protocols of dental implants?
    Turkyilmaz, I.
    McGlumphy, Edwin A.
    JOURNAL OF ORAL REHABILITATION, 2008, 35 (10) : 775 - 781
  • [8] The Effect of Hypothyroidism on Bone Loss at Dental Implants
    Ursomanno, Brendon L.
    Cohen, Robert E.
    Levine, Michael J.
    Yerke, Lisa M.
    JOURNAL OF ORAL IMPLANTOLOGY, 2021, 47 (02) : 131 - 134
  • [9] Comparative evaluation of the peri-implant bone tissue mineral density around unloaded titanium dental implants
    Traini, Tonino
    Degidi, Marco
    Iezzi, Giovanna
    Artese, Luciano
    Piattelli, Adriano
    JOURNAL OF DENTISTRY, 2007, 35 (01) : 84 - 92
  • [10] Primary Stability of Zirconia Dental Implants with Cylindrical and Tapered Designs Across Varying Bone Densities: An In Vitro Evaluation
    Fernandes, Diogo
    Cavaco, Francisco
    Freitas, Filipe
    Marques, Duarte
    Carames, Joao
    Moreira, Andre
    DENTISTRY JOURNAL, 2024, 12 (11)