Ultra-thin flexible polyimide neural probe embedded in a dissolvable maltose-coated microneedle

被引:133
作者
Xiang, Zhuolin [1 ,2 ]
Yen, Shih-Cheng [1 ,2 ]
Xue, Ning [3 ]
Sun, Tao [3 ]
Tsang, Wei Mong [3 ]
Zhang, Songsong [1 ,3 ]
Liao, Lun-De [2 ]
Thakor, Nitish V. [2 ,4 ]
Lee, Chengkuo [1 ,2 ]
机构
[1] Natl Univ Singapore, Dept Elect & Comp Engn, Singapore 117576, Singapore
[2] Natl Univ Singapore, Singapore Inst Neurotechnol SiNAPSE, Singapore 117456, Singapore
[3] ASTAR, Inst Microelect IME, Singapore 117685, Singapore
[4] Johns Hopkins Univ, Sch Med, Dept Biomed Engn, Baltimore, MD 21205 USA
基金
新加坡国家研究基金会;
关键词
neural probe; microneedle; dissolvable; maltose; ultra-thin; flexible; SILICON MICROELECTRODE ARRAYS; ELECTRODE ARRAY; BRAIN-TISSUE; DEPTH PROBE; MICROPROBES; FABRICATION; INTERFACE; RESPONSES; IMPLANT; RELEASE;
D O I
10.1088/0960-1317/24/6/065015
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The ultra-thin flexible polyimide neural probe can reduce the glial sheath growth on the probe body while its flexibility can minimize the micromotion between the probe and brain tissue. To provide sufficient stiffness for penetration purposes, we developed a drawing lithography technology for uniform maltose coating to make the maltose-coated polyimide neural probe become a stiff microneedle. The coating thicknesses under different temperature and the corresponding stiffness are studied. It has been proven that the coated maltose is dissolved by body fluids after implantation for a few seconds. Moreover, carbon nanotubes are coated on the neural probe recording electrodes to improve the charge delivery ability and reduce the impedance. Last but not least, the feasibility and recording characteristic of this ultra-thin polyimide neural probe embedded in a maltose-coated microneedle are further demonstrated by in vivo tests.
引用
收藏
页数:11
相关论文
共 76 条
[51]   Response of brain tissue to chronically implanted neural electrodes [J].
Polikov, VS ;
Tresco, PA ;
Reichert, WM .
JOURNAL OF NEUROSCIENCE METHODS, 2005, 148 (01) :1-18
[52]   THIN-FILM MULTIPLE ELECTRODE PROBES - POSSIBILITIES AND LIMITATIONS [J].
PROHASKA, OJ ;
OLCAYTUG, F ;
PFUNDNER, P ;
DRAGAUN, H .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (02) :223-229
[53]   Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex [J].
Rousche, PJ ;
Normann, RA .
JOURNAL OF NEUROSCIENCE METHODS, 1998, 82 (01) :1-15
[54]   Brain-controlled interfaces: Movement restoration with neural prosthetics [J].
Schwartz, Andrew B. ;
Cui, X. Tracy ;
Weber, Douglas J. ;
Moran, Daniel W. .
NEURON, 2006, 52 (01) :205-220
[55]   Neural probe design for reduced tissue encapsulation in CNS [J].
Seymour, John P. ;
Kipke, Daryl R. .
BIOMATERIALS, 2007, 28 (25) :3594-3607
[56]   Novel multi-sided, microelectrode arrays for implantable neural applications [J].
Seymour, John P. ;
Langhals, Nick B. ;
Anderson, David J. ;
Kipke, Daryl R. .
BIOMEDICAL MICRODEVICES, 2011, 13 (03) :441-451
[57]   Controlling cellular reactive responses around neural prosthetic devices using peripheral and local intervention strategies [J].
Shain, W ;
Spataro, L ;
Dilgen, J ;
Haverstick, K ;
Retterer, S ;
Isaacson, M ;
Saltzman, M ;
Turner, JN .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2003, 11 (02) :186-188
[58]   The astrocyte/meningeal cell interface - a barrier to successful nerve regeneration? [J].
Shearer, MC ;
Fawcett, JW .
CELL AND TISSUE RESEARCH, 2001, 305 (02) :267-273
[59]   Thin microelectrodes reduce GFAP expression in the implant site in rodent somatosensory cortex [J].
Stice, Paula ;
Gilletti, Aaron ;
Panitch, Alyssa ;
Muthuswamy, Jit .
JOURNAL OF NEURAL ENGINEERING, 2007, 4 (02) :42-53
[60]   Reliability of signals from a chronically implanted, silicon-based electrode array in non-human primate primary motor cortex [J].
Suner, S ;
Fellows, MR ;
Vargas-Irwin, C ;
Nakata, GK ;
Donoghue, JP .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2005, 13 (04) :524-541