Comparison of a multiplex, bead-based fluorescent assay and immunofluorescence methods for the detection of ANA and ANCA autoantibodies in human serum

被引:51
|
作者
Nifli, Artemissia-Phoebe [1 ]
Notas, George [1 ]
Mamoulaki, Marilena [1 ]
Niniraki, Maria [1 ]
Ampartzaki, Vaso [1 ]
Theodoropoulos, Panayiotis A. [1 ]
Kopnitsky, Mark J. [1 ]
Castanas, Elias [1 ]
机构
[1] Univ Crete, Lab Expt Endocrinol, Sch Med, GR-71003 Iraklion, Greece
关键词
antinuclear antibodies (ANA); antineutroplil cytoplasmic antibodies (ANCA); extractable nuclear antigen (ENA) screen; multiplex bead-based fluorescent assay; autoimmune diseases;
D O I
10.1016/j.jim.2006.02.004
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
l Detection of antinuclear (ANA) and antineutrophil cytoplasmic (ANCA) antibodies is extensively used for establishing a diagnosis in patients with clinical features suggestive of autoimmune disorders. The most common methods for the identification of positive patients' sera for ANA or ANCA are indirect immunofluorescence (IIF) and ELISA-based procedures. Considerable Mort has been made in developing simpler automated assays for routine laboratory use. Recently a commercially available microsphere-based fluorescent assay has been introduced for the detection of ANA and ANCA. The aim of this Study was to compare this technology with routinely used IIF and ELISA procedures, in patients with a suggested autominutne disorder, A highly significant correlation between ELISA procedures for specific antibodies and the microsphere-based assays were obtained for both ANA and ANCA as well as for extractable nuclear antigens ELISA screening, indicating that Multiplex technology could replace individual ELISA tests for the measurement of specific autoantibodies. However, a low sensitivity for identifying HF-positive cases was obtained for both ANA (58-0%) and ANCA (59.1%), although there was a significant correlation between the assays. In conclusion. our data show that a microsphere-based fluorescent assay may be a valid platform for the simultaneous determination of circulating individual ANA and ANCA autoantibodies. Furthermore, multiplexing technology offers several advantages that will probably make it an attractive tool ill the future. Nevertheless, until further Studies are conducted that determine the clinical performance of the multiplex technology, the initial screening of patients for autoantibodies with IIF is still considered necessary. (c) 2006 Elsevier BY All rights reserved.
引用
收藏
页码:189 / 197
页数:9
相关论文
共 50 条
  • [1] A fluorescent bead-based multiplex assay for the simultaneous detection of antibodies to B. burgdorferi outer surface proteins in canine serum
    Wagner, B.
    Freer, H.
    Rollins, A.
    Erb, H. N.
    VETERINARY IMMUNOLOGY AND IMMUNOPATHOLOGY, 2011, 140 (3-4) : 190 - 198
  • [2] Development of a Novel Multiplex Bead-based Assay for Measuring Autoantibodies on Flow Cytometric Platform
    Chauhan, Rajni
    Gupta, Nikita
    Tiwari, Aseem Kumar
    Raina, Vimarsh
    Nandi, Shoma Paul
    IMMUNOLOGICAL INVESTIGATIONS, 2022, 51 (03) : 588 - 601
  • [3] Development of a Multiplex Bead-Based Assay for Detection of Hepatitis C Virus
    Fonseca, Bruna P. F.
    Marques, Christiane F. S.
    Nascimento, Lilian D.
    Mello, Marcelle B.
    Silva, Leila B. R.
    Rubim, Nara M.
    Foti, Leonardo
    Silva, Edimilson D.
    Ferreira, Antonio G. P.
    Krieger, Marco A.
    CLINICAL AND VACCINE IMMUNOLOGY, 2011, 18 (05) : 802 - 806
  • [4] Quantification of equine immunoglobulin A in serum and secretions by a fluorescent bead-based assay
    Schnabel, Christiane L.
    Babasyan, Susanna
    Freer, Heather
    Wagner, Bettina
    VETERINARY IMMUNOLOGY AND IMMUNOPATHOLOGY, 2017, 188 : 12 - 20
  • [5] Comparison of pre-processing methods for multiplex bead-based immunoassays
    Tanja K. Rausch
    Arne Schillert
    Andreas Ziegler
    Angelika Lüking
    Hans-Dieter Zucht
    Peter Schulz-Knappe
    BMC Genomics, 17
  • [6] Comparison of pre-processing methods for multiplex bead-based immunoassays
    Rausch, Tanja K.
    Schillert, Arne
    Ziegler, Andreas
    Lueking, Angelika
    Zucht, Hans-Dieter
    Schulz-Knappe, Peter
    BMC GENOMICS, 2016, 17
  • [7] A Bead-Based Multiplex Assay for the Detection of DNA Viruses Infecting Laboratory Rodents
    Hoefler, Daniela
    Nicklas, Werner
    Mauter, Petra
    Pawlita, Michael
    Schmitt, Markus
    PLOS ONE, 2014, 9 (05):
  • [8] Performance characteristics of a multiplex bead-based assay for the detection of mumps IgG antibodies
    Padron-Regalado, Eriko
    Escudero-Gonzalez, Nicole A.
    El-Badry, Elina
    Kuang, Zhizhou
    Matson, Zachary
    Sowers, Sun
    Brady, Allison
    Crooke, Stephen
    JOURNAL OF IMMUNOLOGY, 2024, 212 (01):
  • [9] Novel bead-based multiplex assay for the quantification of human immune checkpoint biomarkers
    Lehmann, Jason
    Rughwani, Priyanka
    Zhao, Amy
    Jiang, Weiping
    Ji, Shaoquan
    Sun, Binggang
    CANCER RESEARCH, 2019, 79 (13)
  • [10] COMPARISON OF INDIRECT IMMUNOFLUORESCENCE (IIF) ON HEP-2 CELLS, ENZYME-LINKED IMMUNOSORBENT ASSAY (ELISA) AND MULTIPLEX BEAD-BASED IMMUNOASSAY FOR DETECTION OF ANTINUCLEAR ANTIBODIES (ANA) IN SYSTEMIC LUPUS ERYTHEMATOSUS (SLE)
    Aleksandrova, E.
    Verizhnikova, Z.
    Novikov, A.
    Panafidina, T.
    Seredavkina, N.
    Popkova, T.
    Ayzina, T.
    Roggenbuck, D.
    Nasonov, E.
    ANNALS OF THE RHEUMATIC DISEASES, 2015, 74 : 639 - 639