Time-resolved measurements during backside dry etching of fused silica

被引:17
作者
Zimmer, K. [1 ]
Boehme, R. [1 ]
Vass, C. [2 ]
Hopp, B. [2 ]
机构
[1] Leibniz Inst Oberflachenmodifizierung eV, D-04318 Leipzig, Germany
[2] Univ Szeged, Dept Opt & Quantum Elect, H-6720 Szeged, Hungary
关键词
Laser etching; Fused silica; Thin film; Time resolved; LASER-ABLATION; GLASS; REFLECTIVITY; TRANSMISSION; IRRADIATION; FABRICATION; GRATINGS; TOLUENE;
D O I
10.1016/j.apsusc.2009.04.077
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The laser-induced backside dry etching (LIBDE) investigated in this study makes use of a thin metal film deposited at the backside of a transparent sample to achieve etching of the sample surface. For the time-resolved measurements at LIBDE fused silica samples coated with 125 nm tin were used and the reflected and the transmitted laser intensities were recorded with a temporal resolution of about 1 ns during the etching with a similar to 30 ns KrF excimer laser pulse. The laser beam absorption as well as characteristic changes of the reflection of the target surface was calculated in dependence on the laser fluence in the range of 250-2500 mJ/cm(2) and the pulse number from the temporal variations of the reflection and the transmission. The decrease of the time of a characteristic drop in the reflectivity, which can be explained by the ablation of the metal film, correlates with the developed thermal model. However, the very high absorption after the film ablation probably results in very high temperatures near the surface and presumably in the formation of an absorbing plasma. This plasma may contribute to the etching and the surface modification of the substrate. After the first pulse a remaining absorption of the sample was measured that can be discussed by the redeposition of portions of the ablated metal film or can come from the surface modification in the fused silica sample. These near-surface modifications permit laser etching with the second laser pulse, too. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:9617 / 9621
页数:5
相关论文
共 50 条
[41]   Temperature measurements of long sparks in air using time-resolved moire deflectometry [J].
Cheng, Chen ;
He, Hengxin ;
Luo, Bin ;
Liu, Lipeng ;
Chen, Weijiang ;
Bian, Kai ;
Xiang, Nianwen ;
Hu, Jinyang .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2022, 55 (26)
[42]   What time-resolved measurements tell us about femtosecond laser damage? [J].
Melninkitis, Andrius ;
Siaulys, Nerijus ;
Momgaudis, Balys ;
Smalakys, Linas ;
Vaicenavicius, Julius ;
Barkauskaite, Simona ;
Sirutkaitis, Valdas ;
Gallais, Laurent ;
Guizard, Stephane .
LASER-INDUCED DAMAGE IN OPTICAL MATERIALS: 2015, 2015, 9632
[43]   Micro-convex structure-assisted laser-induced backside dry etching for high-efficiency fabrication of micro-groove array on fused silica toward manipulation of wetting characteristics [J].
Huang, Hu ;
An, Hong ;
Qian, Yongfeng ;
Zhang, Zhiyu ;
Jiang, Minqiang ;
Yan, Jiwang .
JOURNAL OF MANUFACTURING PROCESSES, 2025, 145 :236-251
[44]   Observation of explosive crystallization during excimer laser annealing using in situ time-resolved optical reflection and transmission measurements [J].
Kuo, Chil-Chyuan .
JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2009, 209 (06) :2978-2985
[45]   Deep dry etching of fused silica using C4F8/Ar inductively coupled plasmas [J].
Lin, Laicun ;
Jing, Xiangmeng ;
Liu, Fengman ;
Yin, Wen ;
Yu, Daquan ;
Cao, Liqiang .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2017, 28 (01) :480-486
[46]   Fabrication and characterization of large-core Yb/Al-codoped fused silica waveguides using dry etching [J].
Atar, Gil ;
Ternyak, Orna ;
Greental, Doron ;
Eger, David ;
Chechelnitsky, Galina ;
Mazurski, Noa ;
Gouta, Shifra ;
Elbaz, Yehoudit ;
Bruner, Ariel ;
Sfez, Bruno ;
Ruschin, Shlomo .
OPTICAL MATERIALS, 2014, 38 :265-271
[47]   Time-resolved measurements of the sodium emission in the plume generated by laser ablation of myocardium tissue [J].
de Souza, HP ;
Munin, E ;
de Vilhena Paiva, CE ;
Alves, LP ;
Redígolo, ML ;
Pacheco, MTT .
LASER INTERACTION WITH TISSUE AND CELLS XV, 2004, 5319 :196-200
[48]   FLAME CONCENTRATION MEASUREMENTS USING PICOSECOND TIME-RESOLVED LASER-INDUCED FLUORESCENCE [J].
KLASSEN, MS ;
THOMPSON, BD ;
REICHARDT, TA ;
KING, GB ;
LAURENDEAU, NM .
COMBUSTION SCIENCE AND TECHNOLOGY, 1994, 97 (4-6) :391-403
[49]   The 7BM beamline at the APS: a facility for time-resolved fluid dynamics measurements [J].
Kastengren, Alan ;
Powell, Christopher F. ;
Arms, Dohn ;
Dufresne, Eric M. ;
Gibson, Harold ;
Wang, Jin .
JOURNAL OF SYNCHROTRON RADIATION, 2012, 19 :654-657
[50]   Time-resolved measurements of supersonic fuel sprays using synchrotron X-rays [J].
Powell, CF ;
Yue, Y ;
Poola, R ;
Wang, J .
JOURNAL OF SYNCHROTRON RADIATION, 2000, 7 (06) :356-360