Application of Evolution Strategies to the Design of SAR Efficient Parallel Transmit Multi-Spoke Pulses for Ultra-High Field MRI

被引:6
|
作者
Eberhardt, Boris [1 ,2 ]
Poser, Benedikt A. [3 ]
Shah, N. Jon. [4 ,5 ,6 ]
Felder, Jorg [1 ]
机构
[1] Forschungszentrum Julich, Inst Neurosci & Med 4, D-52425 Julich, Germany
[2] Rhein Westfal TH Aachen, D-52062 Aachen, Germany
[3] Maastricht Univ, Dept Cognit Neurosci, Fac Psychol & Neurosci, NL-6211 LK Maastricht, Netherlands
[4] Forschungszentrum Julich, Inst Neurosci & Med 4 & 11, D-52425 Julich, Germany
[5] Rhein Westfal TH Aachen, Dept Neurol, D-52062 Aachen, Germany
[6] JARA BRAIN, Translat Med, D-52074 Aachen, Germany
关键词
Optimization; Radio frequency; Magnetic resonance imaging; Trajectory; Neuroscience; Nonhomogeneous media; Hardware; Parallel transmission; ultra-high field; SAR; evolution strategies; optimization; LEAST-SQUARES OPTIMIZATION; ABSORPTION RATE; RF PULSES; RADIOFREQUENCY PULSE; EXCITATION; POWER; ARRAY; INHOMOGENEITY; ALGORITHM; PHASE;
D O I
10.1109/TMI.2020.3013982
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We present an evolution-strategy based approach to solve the magnitude least squares (MLS) design problem of low flip-angle slice-selective parallel transmit RF pulses for ultra-high field MRI using SAR and peak-RF-constraints. A combined transmit k-space trajectory and RF pulse weight optimization is proposed in two algorithmic steps. The first step is a coarse grid search to find an initial solution that fulfills all constraints for the subsequent multistage optimization. This avoids convergence to the next nearest local minimum. The second step attempts to refine the results using multiple evolution strategies. We compare the performance of our approach with the non-convex optimization methods described in the literature. The proposed algorithm converges for phantom and in vivo data and only requires an initial estimate of the range of suitable regularization parameters. It demonstrates improved excitation homogeneity compared to published spoke-design methods and allows optimization for homogeneity with a subsequent reduction in the SAR burden. Moreover, excitation homogeneity and the SAR burden can be balanced against each other, enabling a further reduction in SAR at the cost of minor relaxations in excitation homogeneity. This feature makes the algorithm a good candidate for SAR limited sequences in ultra-high field imaging. The algorithm is validated using phantom and in vivo measurements obtained with a 16-channel transmit array at 9.4T.
引用
收藏
页码:4225 / 4236
页数:12
相关论文
共 11 条
  • [1] B1 field map synthesis with generative deep learning used in the design of parallel-transmit RF pulses for ultra-high field MRI
    Eberhardt, Boris
    Poser, Benedikt A.
    Shah, N. Jon
    Felder, Joerg
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2022, 32 (03): : 334 - 345
  • [2] Ultra-high field MRI: parallel-transmit arrays and RF pulse design
    Williams, Sydney N.
    McElhinney, Paul
    Gunamony, Shajan
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (02):
  • [3] Two-spoke placement optimization under explicit specific absorption rate and power constraints in parallel transmission at ultra-high field
    Dupas, Laura
    Massire, Aurelien
    Amadon, Alexis
    Vignaud, Alexandre
    Boulant, Nicolas
    JOURNAL OF MAGNETIC RESONANCE, 2015, 255 : 59 - 67
  • [4] A Review of Parallel Transmit Arrays for Ultra-High Field MR Imaging
    Choi, Chang-Hoon
    Webb, Andrew
    Orzada, Stephan
    Kelenjeridze, Mikheil
    Shah, N. Jon
    Felder, Jorg
    IEEE REVIEWS IN BIOMEDICAL ENGINEERING, 2024, 17 : 351 - 368
  • [5] Ultra-high field MRI RF transmit coil arrays
    van Leeuwen, C.
    Steensma, Bart R.
    Raaijmakers, Alexander J. E.
    2020 50TH EUROPEAN MICROWAVE CONFERENCE (EUMC), 2020, : 1055 - 1058
  • [6] Ultra fast electromagnetic field computations for RF multi-transmit techniques in high field MRI
    van den Bergen, Bob
    Stolk, Christiaan C.
    van den Berg, Jan Bouwe
    Lagendijk, Jan J. W.
    Van den Berg, Cornelis A. T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (05): : 1253 - 1264
  • [7] Pulse sequences and parallel imaging for high spatiotemporal resolution MRI at ultra-high field
    Poser, Benedikt A.
    Setsompop, Kawin
    NEUROIMAGE, 2018, 168 : 101 - 118
  • [8] Multi-slice parallel transmission three-dimensional tailored RF (PTX 3DTRF) pulse design for signal recovery in ultra high field functional MRI
    Zheng, Hai
    Zhao, Tiejun
    Qian, Yongxian
    Schirda, Claudiu
    Ibrahim, Tamer S.
    Boada, Fernando E.
    JOURNAL OF MAGNETIC RESONANCE, 2013, 228 : 37 - 44
  • [9] Improving radiofrequency power and specific absorption rate management with bumped transmit elements in ultra-high field MRI
    Sadeghi-Tarakameh, Alireza
    Adriany, Gregor
    Metzger, Gregory J.
    Lagore, Russell L.
    Jungst, Steve
    DelaBarre, Lance
    van de Moortele, Pierre-Francois
    Ugurbil, Kamil
    Atalar, Ergin
    Eryaman, Yigitcan
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (06) : 3485 - 3493
  • [10] Design and applications of water irradiation devoid RF pulses for ultra-high field biomolecular NMR spectroscopy
    Manu, V. S.
    Olivieri, Cristina
    Pavuluri, KowsalyaDevi
    Veglia, Gianluigi
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2022, 24 (31) : 18477 - 18481