Reagent-Free Hydrogen Peroxide Sensing Using Carbon Nanotube Chemiresistors with Electropolymerized Crystal Violet

被引:8
|
作者
Patel, Vinay [1 ]
Saha, Dipankar [2 ]
Kruse, Peter [2 ]
Selvaganapathy, Ponnambalam Ravi [1 ,3 ]
机构
[1] McMaster Univ, Sch Biomed Engn, Hamilton, ON L8S 4K1, Canada
[2] McMaster Univ, Dept Chem & Chem Biol, Hamilton, ON L8S 4M1, Canada
[3] McMaster Univ, Dept Mech Engn, Hamilton, ON L8S 4K1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
hydrogen peroxide; chemiresistive biosensor; solid-state sensor; crystal violet; electropolymerized self-assembled monolayer; ELECTROCHEMICAL DETERMINATION; RAMAN-SPECTROSCOPY; FILM; GLUCOSE; SENSOR; CONDUCTIVITY; ELECTRODES; HYDROQUINONE; OXIDATION; BLOOD;
D O I
10.1021/acsanm.1c04540
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Hydrogen peroxide (H2O2) is an intermediate molecule generated in numerous peroxidase assays used to measure concentrations of biomolecules such as glucose, galactose, and lactate. Here, we develop a solid-state reagent-free chemiresistive H2O2 sensor, which can measure H2O2 over a wide measuring range of 0.5-1000 ppm (0.015-29.4 mM). The sensor was fabricated using a network of functionalized single-walled carbon nanotubes (SWCNTs) as a sensitive layer and a xurographically patterned gold leaf as a contact electrode. The SWCNTs were functionalized with crystal violet to impart selective detection of H2O2. The crystal violet was self-assembled on the SWCNT film and subsequently polymerized via cyclic voltammetry to improve its retention on the sensing layer. The functionalized sensor exhibited good selectivity against common interferents such as uric acid, urea, glucose, and galactose. In addition, the sensor was used to measure in situ H2O2 generated during peroxidase assays performed using enzymes like glucose oxidase. The sensor was tested in standard buffer solutions for both enzymes. The glucose oxidase assay was also demonstrated in spiked pooled human plasma samples. The glucose oxidase-coated sensor exhibited a glucose detection range of 2-20 mM in standard buffer and blood plasma solutions, with a good recovery rate (similar to 95-107%) for glucose measurements in blood plasma.
引用
收藏
页码:3957 / 3966
页数:10
相关论文
共 50 条
  • [41] Electrocatalytic sensing of hydrogen peroxide using a screen printed carbon electrode modified with nitrogen-doped graphene nanoribbons
    Shi, Libo
    Niu, Xiangheng
    Liu, Tingting
    Zhao, Hongli
    Lan, Minbo
    MICROCHIMICA ACTA, 2015, 182 (15-16) : 2485 - 2493
  • [42] Nonenzymatic amperometric sensing of hydrogen peroxide using a glassy carbon electrode modified with a sandwich-structured nanocomposite consisting of silver nanoparticles, Co3O4 and reduced graphene oxide
    Wu, Qian
    Sheng, Qinglin
    Zheng, Jianbin
    MICROCHIMICA ACTA, 2016, 183 (06) : 1943 - 1951
  • [43] Non-enzymatic sensing of hydrogen peroxide using a glassy carbon electrode modified with a nanocomposite made from carbon nanotubes and molybdenum disulfide
    Yuping Lin
    Xian Chen
    Youxiu Lin
    Qian Zhou
    Dianping Tang
    Microchimica Acta, 2015, 182 : 1803 - 1809
  • [44] Quartz Crystal Nano-balance for hydrogen sensing at room temperature using carbon nanotubes aggregates
    Lucci, M.
    Toschi, F.
    Sessa, V.
    Orlanducci, S.
    Tamburri, E.
    Terranova, M. L.
    SMART SENSORS, ACTUATORS, AND MEMS III, 2007, 6589
  • [45] Comparative studies of hybrid functional materials based on different carbon structures decorated with nano-magnetite. Suitable application as platforms for enzyme-free electrochemical sensing of hydrogen peroxide
    Venosta, Lisandro
    Bracamonte, Maria V.
    Rodriguez, Marcela C.
    Jacobo, Silvia E.
    Bercoff, Paula G.
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 248 : 460 - 469
  • [46] Nonenzymatic sensing of hydrogen peroxide using a glassy carbon electrode modified with graphene oxide, a polyamidoamine dendrimer, and with polyaniline deposited by the Fenton reaction
    Tang, Juan
    Huang, Lulu
    Cheng, Yu
    Zhuang, Junyang
    Li, Ping
    Tang, Dianping
    MICROCHIMICA ACTA, 2018, 185 (12)
  • [47] Non-enzymatic sensing of hydrogen peroxide using a glassy carbon electrode modified with a composite consisting of chitosanaEuroencapsulated graphite and platinum nanoparticles
    Chen, Tse-Wei
    Palanisamy, Selvakumar
    Chen, Shen-Ming
    MICROCHIMICA ACTA, 2016, 183 (11) : 2861 - 2869
  • [48] PdAg-decorated three-dimensional reduced graphene oxide-multi-walled carbon nanotube hierarchical nanostructures for high-performance hydrogen peroxide sensing
    Uzunoglu, Aytekin
    Kose, Dursun Ali
    Kose, Kazim
    Gokmese, Ebru
    Gokmese, Faruk
    MRS COMMUNICATIONS, 2018, 8 (03) : 680 - 686
  • [49] Non-enzymatic photoelectrochemical sensing of hydrogen peroxide using hierarchically structured zinc oxide hybridized with graphite-like carbon nitride
    Xi, Xinguo
    Li, Jing
    Wang, Hongmei
    Zhao, Qi
    Li, Hongbo
    MICROCHIMICA ACTA, 2015, 182 (7-8) : 1273 - 1279
  • [50] Sensing hydrogen peroxide using a glassy carbon electrode modified with in-situ electrodeposited platinum-gold bimetallic nanoclusters on a graphene surface
    Xiu Cui
    Shengnan Wu
    Yongxin Li
    Gang (Gary) Wan
    Microchimica Acta, 2015, 182 : 265 - 272