Reagent-Free Hydrogen Peroxide Sensing Using Carbon Nanotube Chemiresistors with Electropolymerized Crystal Violet

被引:8
|
作者
Patel, Vinay [1 ]
Saha, Dipankar [2 ]
Kruse, Peter [2 ]
Selvaganapathy, Ponnambalam Ravi [1 ,3 ]
机构
[1] McMaster Univ, Sch Biomed Engn, Hamilton, ON L8S 4K1, Canada
[2] McMaster Univ, Dept Chem & Chem Biol, Hamilton, ON L8S 4M1, Canada
[3] McMaster Univ, Dept Mech Engn, Hamilton, ON L8S 4K1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
hydrogen peroxide; chemiresistive biosensor; solid-state sensor; crystal violet; electropolymerized self-assembled monolayer; ELECTROCHEMICAL DETERMINATION; RAMAN-SPECTROSCOPY; FILM; GLUCOSE; SENSOR; CONDUCTIVITY; ELECTRODES; HYDROQUINONE; OXIDATION; BLOOD;
D O I
10.1021/acsanm.1c04540
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Hydrogen peroxide (H2O2) is an intermediate molecule generated in numerous peroxidase assays used to measure concentrations of biomolecules such as glucose, galactose, and lactate. Here, we develop a solid-state reagent-free chemiresistive H2O2 sensor, which can measure H2O2 over a wide measuring range of 0.5-1000 ppm (0.015-29.4 mM). The sensor was fabricated using a network of functionalized single-walled carbon nanotubes (SWCNTs) as a sensitive layer and a xurographically patterned gold leaf as a contact electrode. The SWCNTs were functionalized with crystal violet to impart selective detection of H2O2. The crystal violet was self-assembled on the SWCNT film and subsequently polymerized via cyclic voltammetry to improve its retention on the sensing layer. The functionalized sensor exhibited good selectivity against common interferents such as uric acid, urea, glucose, and galactose. In addition, the sensor was used to measure in situ H2O2 generated during peroxidase assays performed using enzymes like glucose oxidase. The sensor was tested in standard buffer solutions for both enzymes. The glucose oxidase assay was also demonstrated in spiked pooled human plasma samples. The glucose oxidase-coated sensor exhibited a glucose detection range of 2-20 mM in standard buffer and blood plasma solutions, with a good recovery rate (similar to 95-107%) for glucose measurements in blood plasma.
引用
收藏
页码:3957 / 3966
页数:10
相关论文
共 50 条
  • [31] Electrochemical Behavior of the 1,10-Phenanthroline Ligand on a Multiwalled Carbon Nanotube Surface and Its Relevant Electrochemistry for Selective Recognition of Copper Ion and Hydrogen Peroxide Sensing
    Gayathri, Prakasam
    Kumar, Annamalai Senthil
    LANGMUIR, 2014, 30 (34) : 10513 - 10521
  • [32] Amperometric Detection of Hydrogen Peroxide Using Glassy Carbon Electrodes Modified with Chromium Hexacyanoferrate/Single-Walled Carbon Nanotube Nanocomposites
    Zhang, Wei
    Wang, Guangfeng
    Zhang, Xiaojun
    Fang, Bin
    ELECTROANALYSIS, 2009, 21 (02) : 179 - 183
  • [33] Electrochemical generation of hydrogen peroxide using carbon black-, carbon nanotube-, and carbon black/carbon nanotube-coated gas-diffusion cathodes: effect of operational parameters and decolorization study
    R. Darvishi Cheshmeh Soltani
    A. Rezaee
    A. R. Khataee
    H. Godini
    Research on Chemical Intermediates, 2013, 39 : 4277 - 4286
  • [34] Electrochemical Sensing of Hydrogen Peroxide Using Prussian Blue@poly(p-phenylenediamine) Coated Multi-walled Carbon Nanotubes
    Jeon, Young-Eun
    Jang, Wonhyeong
    Lee, Gyeong-Geon
    Hong, Hun-Gi
    JOURNAL OF THE KOREAN CHEMICAL SOCIETY-DAEHAN HWAHAK HOE JEE, 2023, 67 (05): : 339 - 347
  • [35] Bienzymatic mediatorless sensing of total hydrogen peroxide with catalase and multi-copper enzyme co-adsorbed at carbon nanotube-modified electrodes
    Draminska, Sylwia
    Bilewicz, Renata
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 248 : 493 - 499
  • [36] Spot-free catalysis using gold carbon nanotube & gold graphene composites for hydrogen evolution reaction
    Siddhardha, R. S. Sai
    Lakshminarayanan, V.
    Ramamurthy, Sai Sathish
    JOURNAL OF POWER SOURCES, 2015, 288 : 441 - 450
  • [37] A facile fluorescent sensing strategy for determination of hydrogen peroxide in foods using a nanohybrid of nanoceria and carbon dots based on the target-promoted electron transfer
    Liu, Shi Gang
    Liu, Siyi
    Yang, Shujuan
    Zhao, Qian
    Deng, Jiehong
    Shi, Xingbo
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 356
  • [38] Noble metal-free modified electrode of exfoliated graphitic carbon nitride/ZnO nanosheets for highly efficient hydrogen peroxide sensing
    Tian, Hailin
    Fan, Huiqing
    Ma, Jiangwei
    Ma, Longtao
    Dong, Guangzhi
    ELECTROCHIMICA ACTA, 2017, 247 : 787 - 794
  • [39] Electrocatalytic sensing of hydrogen peroxide using a screen printed carbon electrode modified with nitrogen-doped graphene nanoribbons
    Libo Shi
    Xiangheng Niu
    Tingting Liu
    Hongli Zhao
    Minbo Lan
    Microchimica Acta, 2015, 182 : 2485 - 2493
  • [40] Sensing characteristics of hydrogen peroxide sensor using carbon-based electrode loaded with perovskite-type oxide
    Shimizu, Y
    Komatsu, H
    Michishita, S
    Miura, N
    Yamazo, N
    SENSORS AND ACTUATORS B-CHEMICAL, 1996, 34 (1-3) : 493 - 498