Preconcentration of total chromium on Dowex 50W-X8 resin loaded with 2-amino-benzenethiol

被引:15
作者
Veni, Sunkara S.
Rao, Gadupudi P. C.
Rao, Mannepalli M.
Seshaiah, Kalluru [1 ]
机构
[1] Sri Venkateswara Univ, Dept Chem, Environm & Analyt Chem Div, Tirupati 517502, Andhra Pradesh, India
[2] Chaoyang Univ Technol, Dept Environm Engn & Management, Taichung 41349, Taiwan
关键词
chromium; 2-amino-benzenethiol; inductively coupled plasma-atomic emission spectrometry; preconcentration;
D O I
10.1080/03067310600847369
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Application of Dowex 50W-X8 loaded with 2-amino-benzenethiol for preconcentration of total chromium (Cr(VI) and Cr(III)) in water samples and subsequent determination by inductively coupled plasma-atomic emission spectrometry was studied. The reagent 2-amino-benzenethiol loaded onto the resin effectively reduced Cr( VI) to Cr( III) and total chromium ( both Cr( VI) and Cr( III)) formed chelate complex with the reagent in the Cr( III) valence state. Experimental parameters such as preconcentration time, solution flow rates, pH, and concentration of the eluent were optimized. The method has been applied for the determination of total chromium in seawater samples in the range of 0.1 - 200 mu g L-1. A detection limit of 0.3 mu g L-1 was achieved, and the relative standard deviation was about 5%.
引用
收藏
页码:1095 / 1103
页数:9
相关论文
共 18 条
[1]   Separation and determination of various elements by cation-exchange chromatography with sodium trimetaphosphate as the eluent [J].
Akseli, A ;
Kutun, S .
JOURNAL OF CHROMATOGRAPHY A, 1999, 847 (1-2) :245-250
[2]   Determination of trace iron in beer using flow injection systems with in-valve column and bead injection [J].
Ampan, P ;
Lapanantnoppakhun, S ;
Sooksamiti, P ;
Jakmunee, J ;
Hartwell, SK ;
Jayasvati, S ;
Christian, GD ;
Grudpan, K .
TALANTA, 2002, 58 (06) :1327-1334
[3]  
[Anonymous], [No title captured]
[4]  
Bandyopadhyay A., 1998, INDIAN J ENV PROT, V18, P662
[5]   Speciation of chromium in steelmaking solid wastes by selective retention on ion-exchange media and determination by isotope dilution inductively coupled plasma mass spectrometry [J].
Coedo, AG ;
Dorado, T ;
Padilla, I ;
Alguacil, FJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (12) :1564-1568
[6]   Method for the separation of uranium(IV) and (VI) oxidation states in natural waters [J].
Duff, MC ;
Amrhein, C .
JOURNAL OF CHROMATOGRAPHY A, 1996, 743 (02) :335-340
[7]  
FAUST SD, 1987, ADSORPTION PROCESS W
[8]   Speciation analysis of chromium by separation on a 5-palmitoyl oxine-functionalized XAD-2 resin and spectrophotometric determination with diphenylcarbazide [J].
Filik, H ;
Dogutan, M ;
Apak, R .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 376 (06) :928-933
[9]   Ammonia removal from wastewater by ion exchange in the presence of organic contaminants [J].
Jorgensen, TC ;
Weatherley, LR .
WATER RESEARCH, 2003, 37 (08) :1723-1728
[10]  
Krishna MVB, 1999, FRESEN J ANAL CHEM, V363, P353