Textile-Reinforced Mortar versus FRP Jacketing in Seismic Retrofitting of RC Columns with Continuous or Lap-Spliced Deformed Bars

被引:136
作者
Bournas, D. A. [1 ]
Triantafillou, T. C. [1 ]
Zygouris, K. [1 ]
Stavropoulos, F. [1 ]
机构
[1] Univ Patras, Dept Civil Engn, GR-26500 Patras, Greece
关键词
CONFINEMENT;
D O I
10.1061/(ASCE)CC.1943-5614.0000028
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The effectiveness of a new structural material, namely, textile-reinforced mortar (TRM), was investigated experimentally in this study as a means of confining oldtype reinforced concrete (RC) columns with limited capacity due to bar buckling or due to bond failure at lap splice regions. Comparisons with equal stiffness and strength fiber-reinforced polymer (FRP) jackets allow for the evaluation of the effectiveness of TRM versus FRP. Tests were carried out on nearly full scale nonseismically detailed RC columns subjected to cyclic uniaxial flexure under constant axial load. Ten cantilevertype specimens with either continuous or lap-spliced deformed longitudinal reinforcement at the floor level were constructed and tested. Experimental results indicated that TRM jacketing is quite effective as a means of increasing the cyclic deformation capacity of oldtype RC columns with poor detailing, by delaying bar buckling and by preventing splitting bond failures in columns with lap-spliced bars. Compared with their FRP counterparts, the TRM jackets used in this study were found to be equally effective in terms of increasing both the strength and deformation capacity of the retrofitted columns. From the response of specimens tested in this study, it can be concluded that TRM jacketing is an extremely promising solution for the confinement of reinforced concrete columns, including poorly detailed ones with or without lap splices in seismic regions.
引用
收藏
页码:360 / 371
页数:12
相关论文
共 13 条
[1]  
[Anonymous], 19983 EN EUR COMM ST
[2]  
[Anonymous], 1993, 101511 EN EUR COMM S
[3]  
BISKINIS DE, 2007, THESIS U PATRAS PATR, P528
[4]  
BOURNAS DA, 2008, THESIS U PATRAS PATR
[5]  
Bournas DA, 2007, ACI STRUCT J, V104, P740
[6]   Seismic retrofitting of columns with lap spliced smooth bars through FRP or concrete jackets [J].
Bousias, Stathis ;
Spathis, Alexis-Loukas ;
Fardis, Michael N. .
JOURNAL OF EARTHQUAKE ENGINEERING, 2007, 11 (05) :653-674
[7]  
BRAMESHUBER W, 2001, FRPRCS 5 FIBER REINF, V2, P1019
[8]  
BRUECKNER A, 2005, P 3 INT C COMP CONST, P1307
[9]  
CURBACH M, 2003, C TEXTILE REINFORCED, P361
[10]  
Curbach M., 1999, STRUCT ENG INT, V9, P289, DOI DOI 10.2749/101686699780481745