Radiation protection issues in dynamic contrast-enhanced (perfusion) computed tomography

被引:19
作者
Brix, Gunnar [1 ]
Lechel, Ursula [1 ]
Nekolla, Elke [1 ]
Griebel, Juergen [1 ]
Becker, Christoph [2 ]
机构
[1] Fed Off Radiat Protect, Dept Med & Occupat Radiat Protect, D-85764 Oberschleissheim, Germany
[2] Hosp Ludwig Maximilians Univ, Grosshadern Clin, Dept Clin Radiol, D-81377 Munich, Germany
关键词
Dynamic contrast enhanced CT; Perfusion CT; Radiation exposure; Health effects; Justification; Optimization; ATOMIC-BOMB SURVIVORS; CT-PERFUSION; DOSE REDUCTION; CANCER; EXPOSURE; PROGRAM; STROKE; BREAST; MODELS;
D O I
10.1016/j.ejrad.2014.11.011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Dynamic contrast-enhanced (DCE) CT studies are increasingly used in both medical care and clinical trials to improve diagnosis and therapy management of the most common life-threatening diseases: stroke, coronary artery disease and cancer. It is thus the aim of this review to briefly summarize the current knowledge on deterministic and stochastic radiation effects relevant for patient protection, to present the essential concepts for determining radiation doses and risks associated with DCE-CT studies as well as representative results, and to discuss relevant aspects to be considered in the process of justification and optimization of these studies. For three default DCE-CT protocols implemented at a latest-generation CT system for cerebral, myocardial and cancer perfusion imaging, absorbed doses were measured by thermoluminescent dosimeters at an anthropomorphic body phantom and compared with thresholds for harmful (deterministic) tissue reactions. To characterize stochastic radiation risks of patients from these studies, life-time attributable cancer risks (LAR) were estimated using sex-, age-, and organ-specific risk models based on the hypothesis of a linear non-threshold dose-response relationship. For the brain, heart and pelvic cancer studies considered, local absorbed doses in the imaging field were about 100-190 mGy (total CTDIvol, 200 mGy), 15-30 mGy ( 16 m Gy) and 80-270 mGy (140 mGy), respectively. According to a recent publication of the International Commission on Radiological Protection (ICRP Publication 118, 2012), harmful tissue reactions of the cerebro- and cardiovascular systems as well as of the lenses of the eye become increasingly important at radiation doses of more than 0.5 Gy. The LARs estimated for the investigated cerebral and myocardial DCE-CT scenarios are less than 0.07% for males and 0.1% for females at an age of exposure of 40 years. For the considered tumor location and protocol, the corresponding LARs are more than 6 times as high. Stochastic radiation risks decrease substantially with age and are markedly higher for females than for males. To balance the diagnostic needs and patient protection, DCE-CT studies have to be strictly justified and carefully optimized in due consideration of the various aspects discussed in some detail in this review. (C) 2014 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:2347 / 2358
页数:12
相关论文
共 80 条
[1]  
American College of Radiology American Society of Neuroradiology, 2013, ACR ASNR SPR PRACT G
[2]  
[Anonymous], SAF INV CT BRAIN PER
[3]  
[Anonymous], CANC GERM 2009 2010
[4]  
[Anonymous], 2011, SUMMARY LOW DOSE RAD
[6]   CT imaging of myocardial perfusion: Possibilities and perspectives [J].
Becker, Alexander ;
Becker, Christoph .
JOURNAL OF NUCLEAR CARDIOLOGY, 2013, 20 (02) :289-296
[7]   Iterative reconstruction methods in X-ray CT [J].
Beister, Marcel ;
Kolditz, Daniel ;
Kalender, Willi A. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2012, 28 (02) :94-108
[8]   Diagnostic Accuracy of CT Perfusion Imaging for Detecting Acute Ischemic Stroke: A Systematic Review and Meta-Analysis [J].
Biesbroek, J. M. ;
Niesten, J. M. ;
Dankbaar, J. W. ;
Biessels, G. J. ;
Velthuis, B. K. ;
Reitsma, J. B. ;
van der Schaaf, I. C. .
CEREBROVASCULAR DISEASES, 2013, 35 (06) :493-501
[9]   Assessment of a theoretical formalism for dose estimation in CT: an anthropomorphic phantom study [J].
Brix, G ;
Lechel, U ;
Veit, R ;
Truckenbrodt, R ;
Stamm, G ;
Coppenrath, EM ;
Griebel, J ;
Nagel, HD .
EUROPEAN RADIOLOGY, 2004, 14 (07) :1275-1284
[10]   Regional blood flow capillary permeability, and compartmental volumes: Measurement with dynamic CT - Initial experience [J].
Brix, G ;
Bahner, ML ;
Hoffmann, UJ ;
Horvath, A ;
Schreiber, W .
RADIOLOGY, 1999, 210 (01) :269-276