Different techniques of static/dynamic guided implant surgery: modalities and indications

被引:127
作者
Vercruyssen, Marjolein
Fortin, Thomas
Widmann, Gerlig
Jacobs, Reinhilde
Quirynen, Marc
机构
关键词
CONE-BEAM CT; COMPUTER-ASSISTED NAVIGATION; TEMPLATE-BASED REGISTRATION; ENDOSSEOUS ORAL IMPLANTS; INTRAOPERATIVE NAVIGATION; TEMPOROMANDIBULAR-JOINT; CLINICAL-EXPERIENCE; DENTAL IMPLANTOLOGY; PLANNING SYSTEM; IMAGE QUALITY;
D O I
10.1111/prd.12056
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
For computer-guided surgery a static surgical guide is used that transfers the virtual implant position from computerized tomographic data to the surgical site. These guides are produced by computer-aided design/computer-assisted manufacture technology, such as stereolithography, or manually in a dental laboratory (using mechanical positioning devices or drilling machines). With computer-navigated surgery the position of the instruments in the surgical area is constantly displayed on a screen with a three-dimensional image of the patient. In this way, the system allows real-time transfer of the preoperative planning and visual feedback on the screen. A workflow of the different systems is presented in this review. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
引用
收藏
页码:214 / 227
页数:14
相关论文
共 87 条
[1]  
[Anonymous], BIOMED IMAGING INTER
[2]   Minimally invasive head holder to improve the performance of frameless stereotactic surgery [J].
Bale, RJ ;
Vogele, M ;
Freysinger, W ;
Gunkel, AR ;
Martin, A ;
Bumm, K ;
Thumfart, WF .
LARYNGOSCOPE, 1997, 107 (03) :373-377
[3]   Computer-assisted neurosurgery by using a noninvasive vacuum-affixed dental cast that acts as a reference base: another step toward a unified approach in the treatment of brain tumors [J].
Bale, RJ ;
Burtscher, J ;
Eisner, W ;
Obwegeser, AA ;
Rieger, M ;
Sweeney, RA ;
Dessl, A ;
Giacomuzzi, SM ;
Twerdy, K ;
Jaschke, W .
JOURNAL OF NEUROSURGERY, 2000, 93 (02) :208-213
[4]  
BouSerhal Charbel, 2002, Clin Implant Dent Relat Res, V4, P156, DOI 10.1111/j.1708-8208.2002.tb00167.x
[5]   Accuracy of image-guided implantology [J].
Brief, J ;
Edinger, D ;
Hassfeld, S ;
Eggers, G .
CLINICAL ORAL IMPLANTS RESEARCH, 2005, 16 (04) :495-501
[6]  
Casap N, 2006, INT J ORAL MAX IMPL, V21, P314
[7]  
Casap N, 2005, INT J ORAL MAX IMPL, V20, P92
[8]   Computer assistance for intraoperative navigation in ENT surgery [J].
Caversaccio, M ;
Freysinger, W .
MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2003, 12 (1-2) :36-51
[9]  
Caversaccio Marco, 2002, Acta Otorhinolaryngol Belg, V56, P51
[10]   Image-to-patient registration techniques in head surgery [J].
Eggers, G. ;
Muehling, J. ;
Marmulla, R. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2006, 35 (12) :1081-1095