Continuous Non-invasive finger cuff CareTaker® comparable to invasive intraarterial pressure in patients undergoing major intra-abdominal surgery

被引:47
作者
Gratz, Irwin [1 ]
Deal, Edward [1 ]
Spitz, Francis [1 ]
Baruch, Martin [2 ]
Allen, I. Elaine [3 ]
Seaman, Julia E. [4 ]
Pukenas, Erin [1 ]
Jean, Smith [1 ]
机构
[1] Rowan Univ, Cooper Univ Hosp, Cooper Med Sch, Dept Anesthesiol, Camden, NJ USA
[2] Empir Technol Corp, Charlottesville, VA USA
[3] Univ Calif San Francisco, Dept Biostat & Epidemiol, San Francisco, CA 94143 USA
[4] Univ Calif San Francisco, Dept Pharmaceut Chem, San Francisco, CA USA
关键词
Non-Invasive; CareTaker; Central blood pressure; Finger cuff; Intra-Arterial pressure; CARDIAC-OUTPUT; MONITORS; ABILITY; PLOT;
D O I
10.1186/s12871-017-0337-z
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Despite increased interest in non-invasive arterial pressure monitoring, the majority of commercially available technologies have failed to satisfy the limits established for the validation of automatic arterial pressure monitoring by the Association for the Advancement of Medical Instrumentation (AAMI). According to the ANSI/AAMI/ISO 81060-2: 2013 standards, the group-average accuracy and precision are defined as acceptable if bias is not greater than 5 mmHg and standard deviation is not greater than 8 mmHg. In this study, these standards are used to evaluate the CareTaker((R)) (CT) device, a device measuring continuous non-invasive blood pressure via a pulse contour algorithm called Pulse Decomposition Analysis. Methods: A convenience sample of 24 patients scheduled for major abdominal surgery were consented to participate in this IRB approved pilot study. Each patient was monitored with a radial arterial catheter and CT using a finger cuff applied to the contralateral thumb. Hemodynamic variables were measured and analyzed from both devices for the first thirty minutes of the surgical procedure including the induction of anesthesia. The mean arterial pressure (MAP), systolic and diastolic blood pressures continuously collected from the arterial catheter and CT were compared. Pearson correlation coefficients were calculated between arterial catheter and CT blood pressure measurements, a Bland-Altman analysis, and polar and 4Q plots were created. Results: The correlation of systolic, diastolic, and mean arterial pressures were 0.92, 0.86, 0.91, respectively (p < 0.0001 for all the comparisons). The Bland-Altman comparison yielded a bias (as measured by overall mean difference) of -0.57, -2. 52, 1.01 mmHg for systolic, diastolic, and mean arterial pressures, respectively with a standard deviation of 7.34, 6.47, 5. 33 mmHg for systolic, diastolic, and mean arterial pressures, respectively (p < 0.001 for all comparisons). The polar plot indicates little bias between the two methods (90%/95% CI at 31.5 degrees/52 degrees, respectively, overall bias = 1.5 degrees) with only a small percentage of points outside these lines. The 4Q plot indicates good concordance and no bias between the methods. Conclusions: In this study, blood pressure measured using the non-invasive CT device was shown to correlate well with the arterial catheter measurements. Larger studies are needed to confirm these results in more varied settings. Most patients exhibited very good agreement between methods. Results were well within the limits established for the validation of automatic arterial pressure monitoring by the AAMI.
引用
收藏
页数:11
相关论文
共 18 条
[1]  
[Anonymous], 2013, 8106022013 ANSIAAMII, P15
[2]  
[Anonymous], 2013, 8106022013 ANSIAAMII, P22
[3]  
[Anonymous], FDA APPL K023723
[4]   Validation of the pulse decomposition analysis algorithm using central arterial blood pressure [J].
Baruch, Martin C. ;
Kalantari, Kambiz ;
Gerdt, David W. ;
Adkins, Charles M. .
BIOMEDICAL ENGINEERING ONLINE, 2014, 13
[5]  
Baruch Martin C, 2011, Nonlinear Biomed Phys, V5, P1, DOI 10.1186/1753-4631-5-1
[6]   RELATIONSHIP BETWEEN PULSE-WAVE VELOCITY AND ARTERIAL ELASTICITY [J].
CALLAGHAN, FJ ;
GEDDES, LA ;
BABBS, CF ;
BOURLAND, JD .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1986, 24 (03) :248-254
[7]   Assessment of Trending Ability of Cardiac Output Monitors by Polar Plot Methodology [J].
Critchley, Lester A. ;
Yang, Xiao X. ;
Lee, Anna .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2011, 25 (03) :536-546
[8]   A Critical Review of the Ability of Continuous Cardiac Output Monitors to Measure Trends in Cardiac Output [J].
Critchley, Lester A. ;
Lee, Anna ;
Ho, Anthony M. -H. .
ANESTHESIA AND ANALGESIA, 2010, 111 (05) :1180-1192
[9]   Reducing the number of parameters in 1D arterial blood flow modeling: less is more for patient-specific simulations [J].
Epstein, Sally ;
Willemet, Marie ;
Chowienczyk, Phil J. ;
Alastruey, Jordi .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2015, 309 (01) :H222-H234
[10]   Is the Standard Supplied by the Association for the Advancement of Medical Instrumentation the Measure of All Things for Noninvasive Continuous Hemodynamic Devices? [J].
Fortin, Juergen ;
Lerche, Katja ;
Flot-zinger, Doris ;
O'Brien, Terence .
ANESTHESIOLOGY, 2015, 122 (01) :208-209