The Shikani Seeing Stylet™ for difficult intubation in children:: Initial experience

被引:15
作者
Pfitzner, L [1 ]
Cooper, MG [1 ]
Ho, D [1 ]
机构
[1] Childrens Hosp Westmead, Dept Anaesthesia, Westmead, NSW 2145, Australia
关键词
airway; management; intubation; difficult; technique; equipment : Shikani Seeing Stylet (TM);
D O I
10.1177/0310057X0203000411
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The Shikani Seeing Stylet(TM) is a recently introduced reusable intubating stylet, produced in adult and paediatric versions. It combines features of a fibreoptic bronchoscope and a lightwand. Inside a malleable stainless steel sheath, the Shikani Seeing Stylet(TM) has a fibreoptic cable leading to a distal light source and high-resolution lens. In use, the stylet is placed in the lumen of the selected endotracheal tube and the light source enables the stylet to be used as a lightwand, while the fibreoptic capability enables visualization of the laryngeal inlet. It is portable, relatively inexpensive and easy to maintain. This report describes the use of the stylet on eight occasions in seven children, all of whom were assessed preoperatively as being potentially difficult to intubate. Three had been difficult to intubate previously. All were anaesthetized using inhalational anaesthesia. Once an adequate depth of anaesthesia had been achieved, conventional direct laryngoscopy was performed and identified as Grade 3 in six of the patients and Grade I in one. Tracheal intubation was then attempted using the Shikani Seeing Stylet(TM). On six of the eight occasions the attempt was made by different anaesthetists, none of whom had any, prior clinical experience with the stylet. There were seven successful intubations and one failure in a patient who could not be intubated by any method. The Shikani Seeing Stylet(TM) seems a useful device for use in children with difficult airway problems, suspected cervical spine instability or limited mouth-opening.
引用
收藏
页码:462 / 466
页数:5
相关论文
共 26 条
[11]  
GUTSTEIN HB, 1998, ANESTH CLINN AM, V16, P795
[12]   LIGHTWAND INTUBATION IN CHILDREN WITH ABNORMAL UPPER AIRWAYS [J].
HOLZMAN, RS ;
NARGOZIAN, CD ;
FLORENCE, FB .
ANESTHESIOLOGY, 1988, 69 (05) :784-787
[13]   LIGHTWAND INTUBATION .2. CLINICAL-TRIAL OF A NEW LIGHTWAND FOR TRACHEAL INTUBATION IN PATIENTS WITH DIFFICULT AIRWAYS [J].
HUNG, OR ;
PYTKA, S ;
MORRIS, I ;
MURPHY, M ;
STEWART, RD .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1995, 42 (09) :826-830
[14]   LIGHTWAND INTUBATION .1. A NEW LIGHTWAND DEVICE [J].
HUNG, OR ;
STEWART, RD .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1995, 42 (09) :820-825
[15]   Efficiency of a new fiberoptic stylet scope in tracheal intubation [J].
Kitamura, T ;
Yamada, Y ;
Du, HL ;
Hanaoka, K .
ANESTHESIOLOGY, 1999, 91 (06) :1628-1632
[16]  
Kitamura T, 2000, ANESTHESIOLOGY, V92, P1210
[17]   Hemifacial microsomia: anatomical prediction of difficult intubation [J].
Nargozian, C ;
Ririe, DG ;
Bennun, RD ;
Mulliken, JB .
PAEDIATRIC ANAESTHESIA, 1999, 9 (05) :393-398
[18]   Oral and nasotracheal light wand guided intubation after failed fibreoptic bronchoscopy [J].
Rehman, MA ;
Schreiner, MS .
PAEDIATRIC ANAESTHESIA, 1997, 7 (04) :349-351
[19]   Comparison of awake endotracheal intubation in patients with cervical spine disease: The lighted intubating stylet versus the fiberoptic bronchoscope [J].
Saha, AK ;
Higgins, M ;
Walker, G ;
Badr, A ;
Berman, L .
ANESTHESIA AND ANALGESIA, 1998, 87 (02) :477-479
[20]   Swift conversion from laryngoscopic to fiberoptic intubation with a new, handy fiberoptic stylet [J].
Saruki, N ;
Saito, S ;
Sato, J ;
Kon, N ;
Tozawa, R .
ANESTHESIA AND ANALGESIA, 1999, 89 (02) :526-528