Is calibration the cause of variation in liquid chromatography tandem mass spectrometry testosterone measurement?

被引:0
作者
Owen, L. J. [1 ,2 ]
MacDonald, P. R. [2 ]
Keevil, B. G. [1 ,2 ]
机构
[1] Univ Manchester, Manchester Acad Hlth Sci Ctr, Manchester, Lancs, England
[2] Univ S Manchester Hosp, Dept Biochem, Manchester M20 8LR, Lancs, England
基金
英国医学研究理事会; 英国惠康基金;
关键词
Mass spectrometry; laboratory methods; steroid hormones; analytes; SERUM;
D O I
10.1177/0004563212474563
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Testosterone measurement by liquid chromatography tandem mass spectrometry (LC-MS/MS) is well accepted as the preferred technique for the analysis of testosterone. Variation is seen between assays and this may be due to differences in calibration as commercial calibrators for this assay are not readily available. We investigated the effects calibration in routine clinical LC-MS/MS assays. Methods: All LC-MS/MS users that were registered with the UKNEQAS external quality assurance scheme for testosterone were invited to take part in the study. A set of seven serum samples and serum-based calibrators were sent to all laboratories that expressed an interest. The laboratories were instructed to analyse all samples using there own calibrators and return the results and a method questionnaire for analysis. Results: Fifteen laboratories took part in the study. There was no consensus on supplier of testosterone or matrix for the preparation of calibrators and all were prepared in-house. Also, a wide variety of mass spectrometers, internal standards, chromatography conditions and sample extractions were used. The variation in results did not improve when the results were corrected with a common calibrator. Conclusions: The variation in results obtained could not be attributed to variations in calibrators. The differences in methodologies between laboratories must be the reason for this variation.
引用
收藏
页码:368 / 370
页数:3
相关论文
共 7 条
[1]  
Cao Z, 2008, CLIN CHEM, V54, pA113
[2]   Use of a common standard improves the performance of liquid chromatography-tandem mass spectrometry methods for serum 25-hydroxyvitamin-D [J].
Carter, Graham D. ;
Jones, Julia C. .
ANNALS OF CLINICAL BIOCHEMISTRY, 2009, 46 :79-81
[3]   Simultaneous determination of androstenedione and testosterone in human serum by liquid chromatography-tandem mass spectrometry [J].
Gallagher, L. M. ;
Owen, L. J. ;
Keevil, B. G. .
ANNALS OF CLINICAL BIOCHEMISTRY, 2007, 44 :48-56
[4]   Testosterone measurement by liquid chromatography tandem mass spectrometry: the importance of internal standard choice [J].
Owen, L. J. ;
Keevil, B. G. .
ANNALS OF CLINICAL BIOCHEMISTRY, 2012, 49 :600-602
[5]   State-of-the-art of serum testosterone measurement by isotope dilution-liquid chromatography-tandem mass spectrometry [J].
Thienpont, Linda M. ;
Van Uytfanghe, Katleen ;
Blincko, Stuart ;
Ramsay, Carol S. ;
Xie, Hui ;
Doss, Robert C. ;
Keevil, Brian G. ;
Owen, Laura J. ;
Rockwood, Alan L. ;
Kushnir, Mark M. ;
Chun, Kelly Y. ;
Chandler, Donald W. ;
Field, Helen P. ;
Sluss, Patrick M. .
CLINICAL CHEMISTRY, 2008, 54 (08) :1290-1297
[6]   Standardization of testosterone measurements in humans [J].
Vesper, Hubert W. ;
Botelho, Julianne Cook .
JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 2010, 121 (3-5) :513-519
[7]   Interlaboratory Variation in 25-Hydroxyvitamin D2 and 25-Hydroxyvitamin D3 Is Significantly Improved If Common Calibration Material Is Used [J].
Yates, Alexandra Marie ;
Bowron, Ann ;
Calton, Lisa ;
Heynes, Joanne ;
Field, Helen ;
Rainbow, Sandra ;
Keevil, Brian .
CLINICAL CHEMISTRY, 2008, 54 (12) :2082-2084