Polymer-polymer interfacial slip in multilayered films

被引:78
|
作者
Lee, Patrick C. [1 ]
Park, Hee Eon [2 ]
Morse, David C. [1 ]
Macosko, Christopher W. [1 ]
机构
[1] Univ Minnesota, Dept Chem Engn & Mat Sci, Minneapolis, MN 55455 USA
[2] McGill Univ, Dept Chem Engn, Montreal, PQ H3A 2B2, Canada
基金
美国国家科学基金会;
关键词
extrusion; polymer blends; slip; solubility; viscosity; SLIDING PLATE RHEOMETER; MOLECULAR-WEIGHT; FRACTURE ENERGY; WALL SLIP; MELT; ENTANGLEMENT; TRANSITION; ADHESION; FLOW; VISCOSITY;
D O I
10.1122/1.3114370
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
Significant slip can occur in the flow of a blend of two immiscible polymers due to reduced entanglements at their interface. The slip is of practical importance because of its effect on morphology and adhesion in, for example, disordered two-phase blends or multilayer films. Interfacial slip was quantified using two polymer pairs each with closely matched viscosity and elasticity but different miscibility (chi): polypropylene (PP)/polystyrene (PS) chi=0.04 and polyethylene (PE)/fluoropolymer (FP) chi congruent to 0.1. To control the amount of interfacial area, we prepared alternating layers by coextrusion. The number of layers of PP/PS ranged from 20 to 640 while that for PE/FP was 80. Nominal viscosity of the multilayer samples was measured with three types of rheometers: an in-line slit-die rheometer, rotational parallel-disks, and sliding plate. Good agreement was found between the three methods. The nominal viscosity as well as shear normal stresses of the multilayer samples decreased with the number of layers. From the viscosity reduction, an apparent interfacial slip velocity V-slip was calculated. The detectable slip, about 1 mu m/s, occurred at the same level of stress normalized by average plateau modulus tau/G(N,av)(0)=0.01 for both pairs. However, V-slip did not show a sudden increase at a critical shear stress as predicted by Brochard-Wyart and de Gennes [C. R. Acad. Sci., Ser. II: Mec., Phys., Chim., Sci. Terre Univers 317, 13 (1993)] but rather increased V-slip proportional to tau(n), where n approximate to 3 for PS/PP and n approximate to 6 for PE/FP. The steeper dependence of slip on stress for PE/FP may be related to its higher chi value and with its narrower molecular weight distribution.
引用
收藏
页码:893 / 915
页数:23
相关论文
共 50 条
  • [21] POLYMER-POLYMER INTERACTIONS
    PAUL, DR
    PURE AND APPLIED CHEMISTRY, 1995, 67 (06) : 977 - 984
  • [22] POLYMER-POLYMER INTERDIFFUSION
    BROCHARD, F
    DEGENNES, PG
    EUROPHYSICS LETTERS, 1986, 1 (05): : 221 - 224
  • [23] Essential work of interfacial fracture:: a method to characterise adhesion at polymer-polymer interfaces
    Lauke, B
    Schüller, T
    INTERNATIONAL JOURNAL OF ADHESION AND ADHESIVES, 2001, 21 (01) : 55 - 58
  • [24] Interfacial slip in entrained soap films containing associating hydrosoluble polymer
    Adelizzi, EA
    Troian, SM
    LANGMUIR, 2004, 20 (18) : 7482 - 7492
  • [25] THE MEASUREMENT OF INTERFACIAL-TENSION IN POLYMER-POLYMER SYSTEMS - THE BREAKING THREAD METHOD
    ELEMANS, PHM
    JANSSEN, JMH
    MEIJER, HEH
    JOURNAL OF RHEOLOGY, 1990, 34 (08) : 1311 - 1325
  • [26] In situ polymer-polymer composites
    Pesneau, I
    Kadi, AA
    Bousmina, M
    Cassagnau, P
    Michel, A
    ANTEC '99: PLASTICS BRIDGING THE MILLENNIA, CONFERENCE PROCEEDINGS, VOLS I-III: VOL I: PROCESSING; VOL II: MATERIALS; VOL III: SPECIAL AREAS;, 1999, : 2661 - 2664
  • [27] ASPECTS OF POLYMER-POLYMER THERMODYNAMICS
    MCMASTER, LP
    MACROMOLECULES, 1973, 6 (05) : 760 - 773
  • [28] POLYMER-POLYMER MISCIBILITY THERMODYNAMICS
    ANDREI, DC
    ANDREI, C
    REVISTA DE CHIMIE, 1991, 42 (10-12): : 490 - 497
  • [29] FRICTION AT A POLYMER-POLYMER INTERFACE
    BROCHARDWYART, F
    VIDE-SCIENCE TECHNIQUE ET APPLICATIONS, 1994, (272): : 195 - 197
  • [30] DIFFUSION IN POLYMER-POLYMER MIXTURES
    FOLEY, G
    COHEN, C
    JOURNAL OF POLYMER SCIENCE PART B-POLYMER PHYSICS, 1987, 25 (09) : 2027 - 2031