Optimized Design of Ground-Source Heat Pump System Heat Exchanger

被引:0
|
作者
Shi, Zhigang [1 ]
Song, Shangping [1 ]
Hu, Songtao [1 ]
机构
[1] Qingdao Technol Univ, Sch Environm & Municipal Engn, Qingdao, Peoples R China
来源
PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 2: HVAC&R COMPONENT AND ENERGY SYSTEM | 2014年 / 262卷
关键词
Ground-source heat pump; Heat exchanger; Optimized design; PERFORMANCE;
D O I
10.1007/978-3-642-39581-9_71
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The research of heat pump mainly focus on experimental research which emphasizes the determination of heat transfer per unit depth, system COP, reasonable buried pipe spacing, soil thermal physical property and so on, but there has been no breakthrough in the aspect of how to ensure the reliability of the system during a long runtime. This paper first heat exchanger, heat pump, the mathematical pump and buildings was modeled and integrated by the mean of connection condition. The optimized method of the heat exchanger was puts forward. The drill hole depth and drilling hole number are taken as optimization variables, the inlet temperature as objective function. Through a case study, the tradition calculation and optimized drill length was compared. The result shows the optimized design method can decreased drill length and number.
引用
收藏
页码:723 / 730
页数:8
相关论文
共 50 条
  • [1] Simulation Tool for Ground-Source Heat Pump System with Multiple Ground Heat Exchangers
    Katsura, Tako
    Nagano, Katsunori
    ASHRAE TRANSACTIONS 2018, VOL 124, PT 2, 2018, 124 : 92 - 101
  • [2] On sustainable and efficient design of ground-source heat pump systems
    Grassi, W.
    Conti, P.
    Schito, E.
    Testi, D.
    33RD UIT (ITALIAN UNION OF THERMO-FLUID DYNAMICS) HEAT TRANSFER CONFERENCE, 2015, 655
  • [3] The Likelihood Evaluation of the Heat Exchanger Unit Model Design Method in the Ground Source Heat Pump System Utilizing Heat Exchanger Piles
    Oguma, Masahito
    Funabiki, Ayako
    Satoh, Takashi
    Kakizaki, Takao
    2013 INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY RESEARCH AND APPLICATIONS (ICRERA), 2013, : 680 - 685
  • [4] Heating system of biogas digester by ground-source heat pump
    Shi H.
    Wang T.
    Zhu H.
    Li Y.
    Rong L.
    Pei X.
    Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2010, 26 (02): : 268 - 273
  • [5] Exergy analysis of a hybrid ground-source heat pump system
    Menberg, Kathrin
    Heo, Yeonsook
    Choi, Wonjun
    Ooka, Ryozo
    Choudhary, Ruchi
    Shukuya, Masanori
    APPLIED ENERGY, 2017, 204 : 31 - 46
  • [6] Analysis of Groundwater Advection and Ground-Heat Exchanger Spacing on Intermittent Ground-Source Heat Pump Operation
    Lines, Scott Harold
    Llano-Serna, Marcelo A.
    Williams, David J.
    ENERGY GEOTECHNICS, SEG-2018, 2019, : 19 - 26
  • [7] Operation characteristics and experience of a ground source heat pump system with a vertical ground heat exchanger
    Michopoulos, A.
    Zachariadis, T.
    Kyriakis, N.
    ENERGY, 2013, 51 : 349 - 357
  • [8] A NEW-STYLE GROUND-SOURCE HEAT EXCHANGER AND THE HEAT TRANSFER MODEL
    Zhou, You
    Gong, Guangcai
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 2218 - 2225
  • [9] Integration of a heat exchanger on the supply air with the ground-source heat pump in a passive house - case study
    Radomski, B.
    Drojetzki, L.
    Mroz, T.
    INTERNATIONAL CONFERENCE ON THE SUSTAINABLE ENERGY AND ENVIRONMENTAL DEVELOPMENT, 2019, 214
  • [10] Study on Design Calculation of Heat Exchange for Ground-Source Heat Pump Buried Pipes
    Liu Qiuxin
    Hu Zhongping
    Li Shensheng
    Yang Erping
    Ding Yun
    PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON ASIAN-EUROPEAN ENVIRONMENTAL TECHNOLOGY AND KNOWLEDGE TRANSFER, 2008, : 397 - 402