Frequency, predictors and outcome of stent fracture after sirolimus-eluting stent implantation

被引:86
作者
Umeda, Hisashi [1 ]
Gochi, Tomoko [2 ]
Iwase, Mitsunori [3 ]
Izawa, Hideo [4 ]
Shimizu, Takeshi [5 ]
Ishiki, Ryoji [1 ]
Inagaki, Haruo [1 ]
Toyama, Junji [5 ]
Yokota, Mitsuhiro [6 ]
Murohara, Toyoaki [4 ]
机构
[1] Toyota Mem Hosp, Div Cardiol, Toyota 4718513, Japan
[2] Fujita Hlth Univ, Dept Cardiol, Toyoake, Aichi, Japan
[3] Toyota Mem Hosp, Div Integrated Med, Toyota 4718513, Japan
[4] Nagoya Univ, Grad Sch Med, Dept Cardiol, Nagoya, Aichi 4648601, Japan
[5] Aichi Prefectural Cardiovasc & Resp Ctr, Div Cardiol, Ichinomiya, Japan
[6] Aichi Gakuin Univ, Sch Dent, Dept Genome Sci, Nagoya, Aichi 464, Japan
关键词
Stent; Fracture; Restenosis; Sirolimus; Outcome; RIGHT CORONARY-ARTERY; STRUT FRACTURE; RESTENOSIS; REVASCULARIZATION; STENOSIS;
D O I
10.1016/j.ijcard.2007.12.067
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Recently, stent fracture (SF) of sirolimus-eluting stents (SES) has been shown to be associated with an increased risk of in-stent restenosis. We sought to evaluate the incidence, predictors and clinical outcome of SF after SES implantation in comparable unselected lesions. Methods: A total of 430 lesions of 382 patients treated with SES were analyzed. SF was defined as single or multiple stent strut fracture as well as complete separation of stent segments. Results: At follow-up, SF was identified in 33 of 430 lesions (7.7%). In lesions with SF, the in-stent restenosis was observed more frequently than non-SF lesions (15.2% vs. 4.0%, P=0.004). At 450 days, however, the cumulative rate of major cardiac events was not significantly different between lesions with and without SF (9.1% vs. 7.1%, P=0.722). The risk of SF was independently associated with total stent length (OR 2.22; 95% CI, 1.25 to 3.95; P=0.007), the change in the angulation of the lesion after stenting (OR 1.55; 95% CI, 1.07 to 2.25; P=0.020), and the right coronary artery lesions OR 3.26; 95% CI, 1.18 to 8.96; P=0.022). Conclusions: The occurrence of SF after SES implantation, was found to be relatively common in the particular population, however, did not lead to an increased risk of adverse cardiac events at 450 days, despite a higher incidence of in-stent restenosis. (c) 2008 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:321 / 326
页数:6
相关论文
共 15 条
[1]   Incidence and clinical impact of coronary stent fracture after sirolimus-eluting stent implantation [J].
Aoki, Jiro ;
Nakazawa, Gaku ;
Tanabe, Kengo ;
Hoye, Angela ;
Yamamoto, Hirosada ;
Nakayama, Tomohiro ;
Onuma, Yoshinobu ;
Higashikuni, Yasutomi ;
Otsuki, Syuji ;
Yagishita, Atsuhiko ;
Yachi, Sen ;
Nakajima, Hiroyoshi ;
Hara, Kazuhiro .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2007, 69 (03) :380-386
[2]   Patterns of restenosis after drug-eluting stent implantation: insights from a contemporary and comparative analysis of sirolimus- and paclitaxel-eluting stents [J].
Corbett, Simon J. ;
Cosgrave, John ;
Melzi, Gloria ;
Babic, Rade ;
Biondi-Zoccai, Giuseppe G. L. ;
Godino, Cosmo ;
Morici, Nuccia ;
Airoldi, Flavio ;
Michev, Iassen ;
Montorfano, Matteo ;
Sangiorgi, Giuseppe M. ;
Bonizzoni, Erminio ;
Colombo, Antonio .
EUROPEAN HEART JOURNAL, 2006, 27 (19) :2330-2337
[3]   Late incomplete lesion coverage following Cypher stent deployment for diffuse right coronary artery stenosis [J].
Halkin, A ;
Carlier, S ;
Leon, MB .
HEART, 2004, 90 (08) :e45
[4]  
Hamilos Michalis I, 2005, Hellenic J Cardiol, V46, P439
[5]   Stent fracture associated with drug-eluting stents: Clinical characteristics and implications [J].
Lee, Michael S. ;
Jurewitz, Daniel ;
Aragon, Joseph ;
Forrester, James ;
Makkar, Raj R. ;
Kar, Saibal .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2007, 69 (03) :387-394
[6]   Frequency of Stent fracture as a cause of coronary restenosis after sirolimus-eluting stent implantation [J].
Lee, Sang-Hee ;
Park, Jong-Seon ;
Shin, Dong-Gu ;
Kim, Young-Jo ;
Hong, Gue-Ru ;
Kim, Woong ;
Shim, Bong-Sup .
AMERICAN JOURNAL OF CARDIOLOGY, 2007, 100 (04) :627-630
[7]   Unrestricted utilization of sirolimus-eluting stents compared with conventional bare stent implantation in the "real world" -: The Rapamycin-Eluting Stent Evaluated At Rotterdam Cardiology Hospital (RESEARCH) Registry [J].
Lemos, PA ;
Serruys, PW ;
van Domburg, RT ;
Saia, F ;
Arampatzis, CA ;
Hoye, A ;
Degertekin, M ;
Tanabe, K ;
Daemen, J ;
Liu, TKK ;
McFadden, E ;
Sianos, G ;
Hofma, SH ;
Smits, PC ;
van der Giessen, WJ ;
de Feyter, PJ .
CIRCULATION, 2004, 109 (02) :190-195
[8]   Delayed strut fracture of sirolimus-eluting stent: A significant problem or an occasional observation? [J].
Min, PK ;
Yoon, YW ;
Kwon, HM .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2006, 106 (03) :404-406
[9]   A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. [J].
Morice, M ;
Serruys, PW ;
Sousa, JE ;
Fajadet, J ;
Hayashi, EB ;
Perin, M ;
Colombo, A ;
Schuler, G ;
Barragan, P ;
Guagliumi, G ;
Molnar, F ;
Falotico, R .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (23) :1773-1780
[10]   Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery [J].
Moses, JW ;
Leon, MB ;
Popma, JJ ;
Fitzgerald, PJ ;
Holmes, DR ;
O'Shaughnessy, C ;
Caputo, RP ;
Kereiakes, DJ ;
Williams, DO ;
Teirstein, PS ;
Jaeger, JL ;
Kuntz, RE .
NEW ENGLAND JOURNAL OF MEDICINE, 2003, 349 (14) :1315-1323