Management of abdominal aortic prosthetic graft and endograft infections. A multidisciplinary update

被引:42
作者
Antonello, Roberta Maria [1 ]
D'Oria, Mario [2 ,3 ]
Cavallaro, Marco [4 ]
Dore, Franca [5 ]
Cova, Maria Assunta [4 ]
Ricciardi, Maria Chiara [4 ]
Comar, Manola [6 ,7 ]
Campisciano, Giuseppina [7 ]
Lepidi, Sandro [8 ]
De Martino, Randall R. [2 ]
Chiarandini, Stefano [3 ]
Luzzati, Roberto [9 ]
Di Bella, Stefano [9 ]
机构
[1] Univ Trieste, Sch Med, Trieste, Italy
[2] Mayo Clin, Gonda Vasc Ctr, Div Vasc & Endovasc Surg, Rochester, MN USA
[3] Univ Hosp Trieste ASUITS, Cardiovasc Dept, Div Vasc & Endovasc Surg, Trieste, Italy
[4] Univ Hosp Trieste ASUITS, Radiol Dept, Trieste, Italy
[5] Univ Hosp Trieste ASUITS, Nucl Med Unit, Trieste, Italy
[6] Univ Trieste, Med Sci Dept, Trieste, Italy
[7] IRCCS Burlo Garofolo Trieste, Inst Maternal & Child Hlth, Trieste, Italy
[8] Univ Padua, Dept Cardiac Thorac & Vasc Sci, Div Vasc & Endovasc Surg, Padua, Italy
[9] Univ Hosp Trieste ASUITS, Infect Dis Dept, Via Giovanni Sai 1-3, I-34128 Trieste, Italy
关键词
Aorta; Abdominal; Blood vessel prosthesis; Graft infection; Vascular diseases; IN-SITU RECONSTRUCTION; CRYOPRESERVED ARTERIAL ALLOGRAFTS; STAPHYLOCOCCUS-AUREUS BACTEREMIA; FEMORAL-POPLITEAL VEIN; ANTIMICROBIAL THERAPY; FEMOROPOPLITEAL VEIN; IMPREGNATED GRAFTS; MYCOTIC-ANEURYSMS; EDITORS CHOICE; BIOFILM CELLS;
D O I
10.1016/j.jiac.2019.05.013
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Abdominal aortic graft infections (AGIs) occur in 1-5% of aortic prosthetic placements. It can result in limb amputation, pseudo-aneurysm formation, septic emboli, aorto-enteric fistulae, septic shock and death. The most frequently involved pathogens are methicillin-susceptible Staphylococcus aureus, methicillin-resistant Staphylococcus aureus and coagulase-negative staphylococci, followed by Enterobacteriaceae and uncommon bacteria. In case of gut involvement the presence of fungi has to be considered. Computed tomography angiography is actually the gold standard diagnostic imaging but magnetic resonance is a valid alternative. Nuclear medicine imaging is commonly used to improve sensitivity and specificity. Signs and symptoms are often aspecific and blood cultures can be negative, requiring alternative ways to detect the microorganism responsible for infection, such as 16S rRNA gene sequencing and molecular rapid diagnostic tests. Curative surgical intervention is the first choice approach, with in-situ reconstruction providing by far the best outcome and xenopericardial bovine patch as a promising option. For patients unable to undergo major surgery, the outcome of conservative approach remains uncertain but usually provides for life-long suppressive therapy. However, in selected cases an attempt of stopping antibiotic treatment after 3-6 months can be done. Given the difficulty in their management, we performed a review of AGIs, in order to raise awareness on clinical presentation, current available diagnostic tools, prophylaxis, surgical and anti-infective treatment of AGIs. (c) 2019 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:669 / 680
页数:12
相关论文
共 110 条
  • [1] Ten Years Experience of Treating Aorto-Femoral Bypass Graft Infection with Venous Allografts
    Aavik, A.
    Lieberg, J.
    Kals, J.
    Pulges, A.
    Kals, M.
    Lepner, U.
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2008, 36 (04) : 432 - 437
  • [2] Long-term results of the treatment of aortic graft infection by in situ replacement with femoral popliteal vein grafts
    Ali, Ahsan T.
    Modrall, J. Gregory
    Hocking, Jennie
    Valentine, R. James
    Spencer, Horace
    Eidt, John F.
    Clagett, G. Patrick
    [J]. JOURNAL OF VASCULAR SURGERY, 2009, 50 (01) : 30 - 39
  • [3] Neoaortic Xenoprosthetic Grafts for Treatment of Mycotic Aneurysms and Infected Aortic Grafts
    Anibueze, Chukwudubem
    Sankaran, Visesh
    Sadat, Umar
    Tan, Kelvin
    Wilson, Yvonne G.
    Brightwell, Robert E.
    Delbridge, Michael S.
    Stather, Philip W.
    [J]. ANNALS OF VASCULAR SURGERY, 2017, 44 : 419.e1 - 419.e12
  • [4] Prosthetic vascular graft infection: A risk factor analysis using a case-control study
    Antonios, Vera S.
    Noel, Audra A.
    Steckelberg, James M.
    Wilson, Walter R.
    Mandrekar, Jayawant N.
    Harmsen, William S.
    Baddour, Larry M.
    [J]. JOURNAL OF INFECTION, 2006, 53 (01) : 49 - 55
  • [5] Outcome after endovascular stent graft repair of aortoenteric fistula: A systematic review
    Antoniou, George A.
    Koutsias, Stylianos
    Antoniou, Stavros A.
    Georgiakakis, Andreas
    Lazarides, Miltos K.
    Giannoukas, Athanasios D.
    [J]. JOURNAL OF VASCULAR SURGERY, 2009, 49 (03) : 782 - 789
  • [6] Prospective Evaluation of Post-implantation Inflammatory Response After EVAR for AAA: Influence on Patients' 30 Day Outcome
    Arnaoutoglou, E.
    Kouvelos, G.
    Papa, N.
    Kallinteri, A.
    Milionis, H.
    Koulouras, V.
    Matsagkas, M.
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2015, 49 (02) : 175 - 183
  • [7] INCORPORATION VERSUS INFECTION OF RETROPERITONEAL AORTIC GRAFTS - MR IMAGING FEATURES
    AUFFERMANN, W
    OLOFSSON, PA
    RABAHIE, GN
    TAVARES, NJ
    STONEY, RJ
    HIGGINS, CB
    [J]. RADIOLOGY, 1989, 172 (02) : 359 - 362
  • [8] Balink Hans, 2007, Vasc Endovascular Surg, V41, P428, DOI 10.1177/1538574407305094
  • [9] BANDYK DF, 1984, ARCH SURG-CHICAGO, V119, P102
  • [10] Therapeutic options for vancomycin-resistant enterococcal bacteremia
    Barber, Katie E.
    King, S. Travis
    Stover, Kayla R.
    Pogue, Jason M.
    [J]. EXPERT REVIEW OF ANTI-INFECTIVE THERAPY, 2015, 13 (03) : 363 - 377