Influence of thermomechanical aging on marginal gap of CAD-CAM and conventional interim restorations

被引:23
作者
Angwarawong, Thidarat [1 ]
Reeponmaha, Tanapon [2 ]
Angwaravong, Onauma [3 ]
机构
[1] Khon Kaen Univ, Dept Prosthodont, Fac Dent, Khon Kaen 40002, Thailand
[2] Khon Kaen Univ, Fac Dent, Khon Kaen, Thailand
[3] Khon Kaen Univ, Div Pediat Dent, Dept Prevent Dent, Fac Dent, Khon Kaen, Thailand
关键词
PROVISIONAL RESIN CROWNS; FIXED DENTAL PROSTHESES; IN-VITRO EVALUATION; POLYMERIZATION SHRINKAGE; CAD/CAM; FIT; ADAPTATION; ACCURACY;
D O I
10.1016/j.prosdent.2020.03.036
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Computer-aided design and computer-aided manufacturing (CAD-CAM) milling and 3-dimensional printing are readily available for the fabrication of interim restorations. However, studies comparing the marginal gap after a long period of function are lacking. Purpose. The purpose of this in vitro study was to evaluate the marginal gap of interim crowns fabricated from different materials and with different techniques before and after receiving simulated oral stress. Material and methods. Two conventional resins, a polymethyl methacrylate resin (Unifast Trad) and a bis-acryl resin (Protemp 4), a milled polymethyl methacrylate resin (Brylic Solid), and a 3-dimensionally printed bis-acrylate resin (Freeprint Temp) were evaluated. Interim crowns (n=10/group) were fabricated by using the conventional direct technique for Unifast Trad and Protemp 4, with a maxillary molar Dentiform tooth as a template and by using CAD-CAM for Brylic Solid and Freeprint Temp. After finishing and cementation, the marginal gap was measured at the middle of all surfaces and line angles. The average value from all 8 sites was used to represent the marginal gap of each specimen. Subsequently, all interim crowns were thermocycled (5000 cycles of 5 degrees C and 55 degrees C), and cyclic occlusal load with a 5-mm steel ball at central pit (100 000 at 100 N) and the marginal gap were remeasured. The effects of different material types and aging on marginal gap were analyzed with 2-way ANOVA. The difference in marginal gap before and after aging was analyzed by using the paired t test, and the increased marginal gap was analyzed with 1-way ANOVA (alpha=.05). Results. Both the material types and the aging regimen had a significant effect on marginal gap ( P<.001). The Unifast Trad group and the Protemp 4 group had a significantly larger marginal gap than the Brylic Solid group and the Freeprint Temp group, both before and after aging ( P<.01). Each group had a significantly larger marginal gap after the aging regimen ( P<.001). The increased marginal gap was greatest in the Unifast Trad group, which differed statistically from the Freeprint Temp group ( P=.004) but not from the other groups ( P>.05). Conclusions. The interim crowns fabricated with the Brylic Solid and the Freeprint Temp had a smaller marginal gap than those fabricated with Unifast Trad and Protemp 4, both before and after aging. The Unifast Trad group showed a significantly larger increase in marginal gap after the aging regimen than the Freeprint Temp group.
引用
收藏
页码:566.e1 / 566.e6
页数:6
相关论文
共 30 条
[1]  
Abdullah AO, 2016, J APPL ORAL SCI, V24, P258
[2]   Advancements in CAD/CAM technology: Options for practical implementation [J].
Alghazzawi, Tariq F. .
JOURNAL OF PROSTHODONTIC RESEARCH, 2016, 60 (02) :72-84
[3]  
Amin Bhavya Mohandas, 2015, Contemp Clin Dent, V6, P161, DOI 10.4103/0976-237X.156035
[4]   Mechanical properties of provisional dental materials: A systematic review and metaanalysis [J].
Astudillo-Rubio, Daniela ;
Delgado-Gaete, Andres ;
Bellot-Arcis, Carlos ;
Maria Montiel-Company, Jose ;
Pascual-Moscardo, Agustin ;
Manuel Almerich-Silla, Jose .
PLOS ONE, 2018, 13 (02)
[5]   Correlation between polymerization shrinkage and marginal fit of temporary crowns [J].
Balkenhol, Markus ;
Knapp, Michael ;
Ferger, Paul ;
Heun, Ulrich ;
Woestmann, Bernd .
DENTAL MATERIALS, 2008, 24 (11) :1575-1584
[6]   Effects of occlusal loading and thermocycling on the marginal gaps of light-polymerized and autopolymerized resin provisional crowns [J].
Dubois, RJ ;
Kyriakakis, P ;
Weiner, S ;
Vaidyanathan, TK .
JOURNAL OF PROSTHETIC DENTISTRY, 1999, 82 (02) :161-166
[7]   A comparative evaluation of vertical marginal fit of provisional crowns fabricated by computer-aided design/computer-aided manufacturing technique and direct (intraoral technique) and flexural strength of the materials: An in vitro study [J].
Dureja, Ishita ;
Yadav, Bhupender ;
Malhotra, Puja ;
Dabas, Nupur ;
Bhargava, Akshay ;
Pahwa, Ripul .
JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2018, 18 (04) :314-320
[8]  
Edelhoff D, 2012, QUINTESSENCE INT, V43, P457
[9]   Long-term effects of storage and thermal cycling on the marginal adaptation of provisional resin crowns: A pilot study [J].
Ehrenberg, D ;
Weiner, GI ;
Weiner, S .
JOURNAL OF PROSTHETIC DENTISTRY, 2006, 95 (03) :230-236
[10]   Changes in marginal gap size of provisional resin crowns after occlusal loading and thermal cycling [J].
Ehrenberg, DS ;
Weiner, S .
JOURNAL OF PROSTHETIC DENTISTRY, 2000, 84 (02) :139-148