No Difference in Implant Micromotion Between Hybrid Fixation and Fully Cemented Revision Total Knee Arthroplasty A Randomized Controlled Trial with Radiostereometric Analysis of Patients with Mild-to-Moderate Bone Loss

被引:25
作者
Heesterbeek, P. J. C. [1 ,2 ]
Wymenga, A. B. [1 ,3 ]
van Hellemondt, G. G. [1 ,3 ]
机构
[1] St Maartens Clin, Dept Orthopaed & Res, Nijmegen, Netherlands
[2] St Maartens Clin, Dept Res, Nijmegen, Netherlands
[3] St Maartens Clin, Dept Orthopaed, Nijmegen, Netherlands
关键词
COMPONENT STABILITY; TIBIAL COMPONENTS; FOLLOW-UP; STEMS; TKA; PAIN; END;
D O I
10.2106/JBJS.15.00909
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: In revision total knee arthroplasty (TKA), the femoral component and tibial baseplate are usually cemented. However, stems can be fixed either with cement or with a press-fit technique, with the latter resulting in hybrid fixation. There is no consensus on the preferred stem fixation technique. Therefore, we compared the stability of cemented TKA implants with the stability of TKA implants fixed with the hybrid technique in a prospective randomized trial using radiostereometric analysis (RSA). Methods: Thirty-two patients with a Type-I or II bone defect who needed revision TKA and were randomly allocated at the time of surgery into either the cemented or hybrid-fixation group were included in the study. The radiographs for the RSA were obtained during hospitalization (baseline); at 6 weeks; and at 3, 6, 12, and 24 months. Migration of the femoral and tibial implants was measured using model-based RSA and expressed along or around the 3 orthogonal axes and as total translation (TT) and total rotation (TR). Clinical results were evaluated using the Knee Society Score (KSS), the Knee injury and Osteoarthritis Outcome Score (KOOS), active flexion, and visual analog scale (VAS) scores for pain and satisfaction. Mann-Whitney and chi-square tests were used to compare migration and clinical outcomes between the cement and hybrid techniques. Results: At 24 months, no difference in median migration or the number of migrating components was found between the cemented and hybrid-fixation groups. In each group, approximately one-third of the tibial components had total rotation of >1 degrees. The clinical scores did not differ between the techniques. Conclusions: At 24 months after revision TKAs, cemented and hybrid-fixation replacements were equally stable. Unexpectedly, both groups had implants with >1 mm or >1 degrees of micromotion although there were no clinical or radiographic signs of loosening. Whether these findings indicate the possibility of loosening with longer follow-up remains to be investigated.
引用
收藏
页码:1359 / 1369
页数:11
相关论文
共 23 条
  • [1] The effect of stem design on end-of-stem pain in revision total knee arthroplasty
    Barrack, RL
    Stanley, T
    Burt, M
    Hopkins, S
    [J]. JOURNAL OF ARTHROPLASTY, 2004, 19 (07) : 119 - 124
  • [2] Barrack RL, 1999, CLIN ORTHOP RELAT R, P216
  • [3] Fixation of revision TKA: a review of the literature
    Beckmann, J.
    Luering, C.
    Springorum, R.
    Koeck, F. X.
    Grifka, J.
    Tingart, M.
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (06) : 872 - 879
  • [4] The influence of stem length and fixation on initial femoral component stability in revision total knee replacement
    Conlisk, N.
    Gray, H.
    Pankaj, P.
    Howie, C. R.
    [J]. BONE & JOINT RESEARCH, 2012, 1 (11): : 281 - 288
  • [5] Classification and preoperative radiographic evaluation: Knee
    Engh, GA
    Ammeen, DJ
    [J]. ORTHOPEDIC CLINICS OF NORTH AMERICA, 1998, 29 (02) : 205 - +
  • [6] Clinical & Radiographic Outcomes of Cemented vs. Diaphyseal Engaging Cementless Stems in Aseptic Revision TKA
    Gililland, Jeremy M.
    Gaffney, Christian J.
    Odum, Susan M.
    Fehring, Thomas K.
    Peters, Christopher L.
    Beaver, Walter B.
    [J]. JOURNAL OF ARTHROPLASTY, 2014, 29 (09) : 224 - 228
  • [7] Midterm Results of Hybrid Cement Technique in Revision Total Knee Arthroplasty
    Greene, Joseph W.
    Reynolds, Shaun M.
    Stimac, Jeffrey D.
    Malkani, Arthur L.
    Massini, Michael A.
    [J]. JOURNAL OF ARTHROPLASTY, 2013, 28 (04) : 570 - 574
  • [8] REVISION TOTAL KNEE ARTHROPLASTY WITH USE OF MODULAR COMPONENTS WITH STEMS INSERTED WITHOUT CEMENT
    HAAS, SB
    INSALL, JN
    MONTGOMERY, W
    WINDSOR, RE
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (11) : 1700 - 1707
  • [9] The effect of stem modularity and mode of fixation on tibial component stability in revision total knee arthroplasty
    Jazrawi, LM
    Bai, B
    Kummer, FJ
    Hiebert, R
    Stuchin, SA
    [J]. JOURNAL OF ARTHROPLASTY, 2001, 16 (06) : 759 - 767
  • [10] A 30-mm Cemented Stem Extension Provides Adequate Fixation of the Tibial Component in Revision Knee Arthroplasty
    Lachiewicz, Paul F.
    Soileau, Elizabeth S.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2015, 473 (01) : 185 - 189