Comparison of Fit of Dentures Fabricated by Traditional Techniques Versus CAD/CAM Technology

被引:52
作者
McLaughlin, J. Bryan [1 ]
Ramos, Van [2 ]
Dickinson, Douglas P. [3 ]
机构
[1] US Army Adv Educ Program Prosthodont, Ft Gordon, GA USA
[2] Univ Washington, Sch Dent, Dept Restorat Dent, Seattle, WA 98195 USA
[3] Ft Gordon Dent Hlth Act, Dept Dent Res, Ft Gordon, GA USA
来源
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | 2019年 / 28卷 / 04期
关键词
CAD; CAM; digital dentures; removable; injection molding; computer-aided design; denture bases; complete dentures; maxilla; maxillary arch; arch form; palate; palate depth; selective laser sintering; 3D printing; titanium; CAD-CAM; ADAPTATION; STABILITY; ACCURACY; PATIENT; TRIAL;
D O I
10.1111/jopr.12604
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose To compare the shrinkage of denture bases fabricated by three methods: CAD/CAM, compression molding, and injection molding. The effect of arch form and palate depth was also tested. Materials and Methods Nine titanium casts, representing combinations of tapered, ovoid, and square arch forms and shallow, medium, and deep palate depths, were fabricated using electron beam melting (EBM) technology. For each base fabrication method, three poly(vinyl siloxane) impressions were made from each cast, 27 dentures for each method. Compression-molded dentures were fabricated using Lucitone 199 poly methyl methacrylate (PMMA), and injection molded dentures with Ivobase's Hybrid Pink PMMA. For CAD/CAM, denture bases were designed and milled by Avadent using their Light PMMA. To quantify the space between the denture and the master cast, silicone duplicating material was placed in the intaglio of the dentures, the titanium master cast was seated under pressure, and the silicone was then trimmed and recovered. Three silicone measurements per denture were recorded, for a total of 243 measurements. Each silicone measurement was weighed and adjusted to the surface area of the respective arch, giving an average and standard deviation for each denture. Results Comparison of manufacturing methods showed a statistically significant difference (p = 0.0001). Using a ratio of the means, compression molding had on average 41% to 47% more space than injection molding and CAD/CAM. Comparison of arch/palate forms showed a statistically significant difference (p = 0.023), with shallow palate forms having more space with compression molding. The ovoid shallow form showed CAD/CAM and compression molding had more space than injection molding. Conclusion Overall, injection molding and CAD/CAM fabrication methods produced equally well-fitting dentures, with both having a better fit than compression molding. Shallow palates appear to be more affected by shrinkage than medium or deep palates. Shallow ovoid arch forms appear to benefit from the use of injection molding compared to CAD/CAM and compression molding.
引用
收藏
页码:428 / 435
页数:8
相关论文
共 39 条
  • [11] Digital Denture Fabrication in Pre- and Postdoctoral Education: A Survey of US Dental Schools
    Fernandez, Monica A.
    Nimmo, Arthur
    Behar-Horenstein, Linda S.
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2016, 25 (01): : 83 - 90
  • [12] Goodacre BJ, 2016, J PROSTHET DENT, V116, P249, DOI 10.1016/j.prosdent.2016.02.017
  • [13] CAD/CAM FABRICATED COMPLETE DENTURES: CONCEPTS AND CLINICAL METHODS OF OBTAINING REQUIRED MORPHOLOGICAL DATA
    Goodacre, Charles J.
    Garbacea, Antoanela
    Naylor, W. Patrick
    Daher, Tony
    Marchack, Christopher B.
    Lowry, Jean
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2012, 107 (01) : 34 - 46
  • [14] FABRICATING COMPLETE DENTURES WITH CAD/CAM TECHNOLOGY
    Infante, Luis
    Yilmaz, Burak
    McGlumphy, Edwin
    Finger, Israel
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2014, 111 (05) : 351 - 355
  • [15] Evaluation of a complete denture trial method applying rapid prototyping
    Inokoshi, Masanao
    Kanazawa, Manabu
    Minakuchi, Shunsuke
    [J]. DENTAL MATERIALS JOURNAL, 2012, 31 (01) : 40 - 46
  • [16] CONTOURS OF THE EDENTULOUS PALATE
    JOHNSON, DL
    HOLT, RA
    DUNCANSON, MG
    [J]. JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1986, 113 (01) : 35 - 40
  • [17] Trial of a CAD/CAM system for fabricating complete dentures
    Kanazawa, Manabu
    Inokoshi, Masanao
    Minakuchi, Shunsuke
    Ohbayashi, Naoto
    [J]. DENTAL MATERIALS JOURNAL, 2011, 30 (01) : 93 - 96
  • [18] Comparison of treatment outcomes in digital and conventional complete removable dental prosthesis fabrications in a predoctoral setting
    Kattadiyil, Mathew T.
    Jekki, Rami
    Goodacre, Charles J.
    Baba, Nadim Z.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2015, 114 (06) : 818 - 825
  • [19] Digitally Planned and Fabricated Mandibular Fixed Complete Dentures. Part 2. Prosthodontic Phase
    Kattadiyil, Mathew T.
    Goodacre, Charles J.
    Lozada, Jaime L.
    Garbacea, Antoanela
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2015, 28 (02) : 119 - 123
  • [20] Kattadiyil Mathew T, 2013, J Calif Dent Assoc, V41, P407