Comparison of Fit of Dentures Fabricated by Traditional Techniques Versus CAD/CAM Technology

被引:52
作者
McLaughlin, J. Bryan [1 ]
Ramos, Van [2 ]
Dickinson, Douglas P. [3 ]
机构
[1] US Army Adv Educ Program Prosthodont, Ft Gordon, GA USA
[2] Univ Washington, Sch Dent, Dept Restorat Dent, Seattle, WA 98195 USA
[3] Ft Gordon Dent Hlth Act, Dept Dent Res, Ft Gordon, GA USA
来源
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | 2019年 / 28卷 / 04期
关键词
CAD; CAM; digital dentures; removable; injection molding; computer-aided design; denture bases; complete dentures; maxilla; maxillary arch; arch form; palate; palate depth; selective laser sintering; 3D printing; titanium; CAD-CAM; ADAPTATION; STABILITY; ACCURACY; PATIENT; TRIAL;
D O I
10.1111/jopr.12604
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose To compare the shrinkage of denture bases fabricated by three methods: CAD/CAM, compression molding, and injection molding. The effect of arch form and palate depth was also tested. Materials and Methods Nine titanium casts, representing combinations of tapered, ovoid, and square arch forms and shallow, medium, and deep palate depths, were fabricated using electron beam melting (EBM) technology. For each base fabrication method, three poly(vinyl siloxane) impressions were made from each cast, 27 dentures for each method. Compression-molded dentures were fabricated using Lucitone 199 poly methyl methacrylate (PMMA), and injection molded dentures with Ivobase's Hybrid Pink PMMA. For CAD/CAM, denture bases were designed and milled by Avadent using their Light PMMA. To quantify the space between the denture and the master cast, silicone duplicating material was placed in the intaglio of the dentures, the titanium master cast was seated under pressure, and the silicone was then trimmed and recovered. Three silicone measurements per denture were recorded, for a total of 243 measurements. Each silicone measurement was weighed and adjusted to the surface area of the respective arch, giving an average and standard deviation for each denture. Results Comparison of manufacturing methods showed a statistically significant difference (p = 0.0001). Using a ratio of the means, compression molding had on average 41% to 47% more space than injection molding and CAD/CAM. Comparison of arch/palate forms showed a statistically significant difference (p = 0.023), with shallow palate forms having more space with compression molding. The ovoid shallow form showed CAD/CAM and compression molding had more space than injection molding. Conclusion Overall, injection molding and CAD/CAM fabrication methods produced equally well-fitting dentures, with both having a better fit than compression molding. Shallow palates appear to be more affected by shrinkage than medium or deep palates. Shallow ovoid arch forms appear to benefit from the use of injection molding compared to CAD/CAM and compression molding.
引用
收藏
页码:428 / 435
页数:8
相关论文
共 39 条
  • [1] Application of digital technology in the prosthodontic management of a patient with myasthenia gravis: A clinical report
    AlHelal, Abdulaziz
    Jekki, Rami
    Richardson, Paul M.
    Kattadiyil, Mathew T.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2016, 115 (05) : 531 - 536
  • [2] DIMENSIONAL STABILITY OF INJECTION AND CONVENTIONAL PROCESSING OF DENTURE BASE ACRYLIC RESIN
    ANDERSON, GC
    SCHULTE, JK
    ARNOLD, TG
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1988, 60 (03) : 394 - 398
  • [3] AVCI M, 1992, International Journal of Prosthodontics, V5, P73
  • [4] EFFECT OF RELINING ON THE ACCURACY AND STABILITY OF MAXILLARY COMPLETE DENTURES - INVITRO AND INVIVO STUDY
    BARCO, MT
    MOORE, BK
    SWARTZ, ML
    BOONE, ME
    DYKEMA, RW
    PHILLIPS, RW
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1979, 42 (01) : 17 - 22
  • [5] Prospective cohort pilot study of 2-visit CAD/CAM monolithic complete dentures and implant-retained overdentures: Clinical and patient-centered outcomes
    Bidra, Avinash S.
    Farrell, Kimberly
    Burnham, David
    Dhingra, Ajay
    Taylor, Thomas D.
    Kuo, Chia-Ling
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2016, 115 (05) : 578 - 586
  • [6] The 2-Visit CAD-CAM Implant-Retained Overdenture: A Clinical Report
    Bidra, Avinash S.
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2014, 40 (06) : 722 - 728
  • [7] COMPUTER-AIDED TECHNOLOGY FOR FABRICATING COMPLETE DENTURES: SYSTEMATIC REVIEW OF HISTORICAL BACKGROUND, CURRENT STATUS, AND FUTURE PERSPECTIVES
    Bidra, Avinash S.
    Taylor, Thomas D.
    Agar, John R.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2013, 109 (06) : 361 - 366
  • [8] Bilgin Mehmet Selim, 2016, Eur J Dent, V10, P286, DOI 10.4103/1305-7456.178304
  • [9] Fabricating Complete Dentures with CAD/CAM and RP Technologies
    Bilgin, Mehmet Selim
    Erdem, Ali
    Aglarci, Osman Sami
    Dilber, Erhan
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2015, 24 (07): : 576 - 579
  • [10] Busch M, 2006, Int J Comput Dent, V9, P113