Computer aided diagnosis method for steatosis rating in ultrasound images using random forests

被引:25
作者
Mihailescu, Dan Mihai [1 ]
Gui, Vasile [1 ]
Toma, Corneliu Ioan [1 ]
Popescu, Alina [2 ]
Sporea, Ioan [2 ]
机构
[1] Politehn Univ, Fac Elect & Telecommun, Dept Telecommun, Bucharest, Romania
[2] Victor Babes Med & Pharm Univ Timisoara, Dept Gastroenterol & Hepatol, Timisoara, Romania
关键词
steatosis; ultrasound image; computer aided design; robust methods; classifier; noninvasive; CHRONIC HEPATITIS-C; LIVER-BIOPSY;
D O I
10.11152/mu.2013.2066.153.dmm1vg2
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In this paper we discuss the problem of computer aided evaluation of the severity of steatosis disease using ultrasound images, the aim of the study being to compare the automatic evaluation of liver steatosis using random forests (RF) and support vector machine (SVM) classifiers. Material and method: One hundred and twenty consecutive patients with steatosis or normal liver, assessed by ultrasound by the same expert, were enrolled. We graded steatosis in four stages and trained two classifiers to rate the severity of disease, based on a large set of labeled images and a large set of features, including several features obtained by robust estimation techniques. We compared RF and SVM classifiers. The classifiers were trained using cross-validation. There was 80% of data randomly selected for training and 20% for testing the classifier. This procedure was performed 20 times. The main measure of performance was the accuracy. Results: From all cases, 10 were rated as normal liver, 70 as having mild, 33 moderate, and 7 severe steatosis. Our best experts' ratings were used as ground truth data. RF outperformed the SVM classifier and confirmed the ability of this classifier to perform well without feature selection. In contrast, the performance of the SVM classifier was poor without feature selection and improved significantly after feature selection. Conclusion: The ability and accuracy of RF to classify well the steatosis severity, without feature selection, were superior as compared to SVM.
引用
收藏
页码:184 / 190
页数:7
相关论文
共 18 条
  • [11] Lupsor M, 2011, IFMBE PROC, V36, P184, DOI 10.1007/978-3-642-22586-4_40
  • [12] Mihailescu DM, 2012, 2012 10TH INTERNATIONAL SYMPOSIUM ON ELECTRONICS AND TELECOMMUNICATIONS, P311, DOI 10.1109/ISETC.2012.6408111
  • [13] Nagy G, 2007, ACTA ELECTROTEHNICA, V4, P217
  • [14] Macrovesicular hepatic steatosis in living liver donors: Use of CT for quantitative and qualitative assessment
    Park, SH
    Kim, PN
    Kim, KW
    Lee, SW
    Yoon, SE
    Park, SW
    Ha, HK
    Lee, MG
    Hwang, S
    Lee, SG
    Yu, ES
    Cho, EY
    [J]. RADIOLOGY, 2006, 239 (01) : 105 - 112
  • [15] Regev A, 2002, AM J GASTROENTEROL, V97, P2614, DOI 10.1111/j.1572-0241.2002.06038.x
  • [16] Ribeiro R, 2012, IEEE ENG MED BIO, P6547, DOI 10.1109/EMBC.2012.6347494
  • [17] Interobserver and Intraobserver variability in the sonographic assessment of fatty liver
    Strauss, Simon
    Gavish, Ella
    Gottlieb, Paul
    Katsnelson, Ludmila
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (06) : W320 - W323
  • [18] Computer-aided diagnosis for contrast-enhanced ultrasound in the liver
    Sugimoto, Katsutoshi
    Shiraishi, Junji
    Moriyasu, Fuminori
    Doi, Kunio
    [J]. WORLD JOURNAL OF RADIOLOGY, 2010, 2 (06): : 215 - 223