VAMS and StAGE as innovative tools for the enantioselective determination of clenbuterol in urine by LC-MS/MS

被引:20
作者
Protti, Michele [1 ]
Sberna, Paolo M. [2 ]
Sardella, Roccaldo [3 ]
Vovk, Tomaz [4 ]
Mercolini, Laura [1 ]
Mandrioli, Roberto [5 ]
机构
[1] Univ Bologna, Dept Pharm & Biotechnol FaBiT, Res Grp Pharmaco Toxicol Anal PTA Lab, Alma Mater Studiorum, Via Belmeloro 6, I-40126 Bologna, Italy
[2] Delft Univ Technol, Dept Microelect, Feldmannweg 17, NL-2628 CT Delft, Netherlands
[3] Univ Perugia, Dept Pharmaceut Sci, Via Fabretti 48, I-06123 Perugia, Italy
[4] Univ Ljubljana, Fac Pharm, Askercecva 7, Ljubljana 1000, Slovenia
[5] Univ Bologna, Dept Life Qual Studies QuVi, Alma Mater Studiorum, Corso Augusto 237, I-47921 Rimini, Italy
关键词
Clenbuterol; LC-MS/MS; Stop-and-go extraction (StAGE); Urine microsampling; Volumetric absorptive microsampling (VAMS); FOOD CONTAMINATION; ENANTIOMERS; SEPARATION; DRUG; AGONISTS; PHASES;
D O I
10.1016/j.jpba.2020.113873
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Clenbuterol is a chiral, selective beta(2)-adrenergic agonist. It is administered as a racemic mixture for therapeutic purposes (as a bronchodilator or prospective neuroprotective agent), but also for non-therapeutic uses (athletic performance enhancement, cattle growth promotion). Aim of the present study is to develop an original, enantioselective workflow for the analysis of clenbuterol enantiomers in urine microsamples. An innovative miniaturised sampling procedure by volumetric absorptive microsampling (VAMS) and a microsample pretreatment strategy based on stop-and-go extraction (StAGE) tips were developed and coupled to an original, chiral analytical method, exploiting liquid chromatography with triple quadrupole detection (LC-MS/MS). The method was validated, with satisfactory results: good linearity (r(2) >= 0.9995) and LOQ values (0.3 ng/mL) were found over suitable concentration ranges. Extraction yield (>87 %), precision (RSD < 4.3 %) and matrix effect (85-90 %) were all within acceptable levels of confidence. After validation, the method was applied to the determination of clenbuterol in dried urine sampled by VAMS from patients taking the drug for therapeutic reasons. Analyte content ranged from 0.8 to 2.5 ng/mL per single enantiomer, with substantial retention of the original drug racemic composition. The VAMS-StAGE-LC-MS/MS workflow seems to be suitable for future application to anti-doping testing of clenbuterol in urine. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:8
相关论文
共 34 条
  • [1] DIMETHYLPHENYLCARBAMATES, DICHLOROPHENYLCARBAMATES AND CHLOROMETHYLPHENYLCARBAMATES OF AMYLOSE AS CHIRAL STATIONARY PHASES FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    CHANKVETADZE, B
    YASHIMA, E
    OKAMOTO, Y
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1995, 694 (01) : 101 - 109
  • [2] Enantio-selective effects of clenbuterol in cultured neurons and astrocytes, and in a mouse model of cerebral ischemia
    Culmsee, Carsten
    Junker, Vera
    Thal, Serge
    Kremers, Wolfram
    Maier, Sandra
    Schneider, Harald Joern
    Plesnila, Nikolaus
    Krieglstein, Josef
    [J]. EUROPEAN JOURNAL OF PHARMACOLOGY, 2007, 575 (1-3) : 57 - 65
  • [3] Stereoselective determination of clenbuterol in human urine by capillary electrophoresis
    Gausepohl, C
    Blaschke, G
    [J]. JOURNAL OF CHROMATOGRAPHY B, 1998, 713 (02): : 443 - 446
  • [4] Ghodse AH, 2010, SIDE EFFECT, V32, P183, DOI 10.1016/S0378-6080(10)32008-3
  • [5] Validation of radioimmunoassay screening methods for -agonists in bovine liver according to Commission Decision 2002/657/EC
    Granja, R. H. M. M.
    Montes Nino, A. M.
    Rabone, F.
    Montes Nino, R. E.
    Cannavan, A.
    Gonzalez Salerno, A.
    [J]. FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2008, 25 (12): : 1475 - 1481
  • [6] Clenbuterol - regional food contamination a possible source for inadvertent doping in sports
    Guddat, S.
    Fusshoeller, G.
    Geyer, H.
    Thomas, A.
    Braun, H.
    Haenelt, N.
    Schwenke, A.
    Klose, C.
    Thevis, M.
    Schaenzer, W.
    [J]. DRUG TESTING AND ANALYSIS, 2012, 4 (06) : 534 - 538
  • [7] Enantiomeric analysis of clenbuterol in Chinese people by LC-MS/MS to distinguish doping abuse from meat contamination
    He, Genye
    Sheng, Linghui
    Zhang, Jianli
    Wu, Yun
    Zhao, Xuxiao
    Xu, Youxuan
    Lu, Jianghai
    [J]. BIOANALYSIS, 2020, 12 (11) : 783 - 790
  • [8] Hefnawy MM, 2013, DIG J NANOMATER BIOS, V8, P1781
  • [9] Kitaura T, 2015, J PHYS FITNESS SPORT, V4, P369
  • [10] Volumetric absorptive microsampling: Current advances and applications
    Kok, Miranda G. M.
    Fillet, Marianne
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 147 : 288 - 296