Survival of airborne microorganisms during swirling aerosol collection

被引:123
作者
Lin, XJ [1 ]
Reponen, T [1 ]
Willeke, K [1 ]
Wang, Z [1 ]
Grinshpun, SA [1 ]
Trunov, M [1 ]
机构
[1] Univ Cincinnati, Dept Environm Hlth, Aerosol Res & Exposure Assessment Lab, Cincinnati, OH 45267 USA
关键词
D O I
10.1080/027868200303722
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
An earlier study evaluated the physical performance of the Swirling Aerosol Collector, also known as the "BioSampler," and found it to have several advantages over the widely used AGI-30 impinger when tested with inert test particles. The present study was Focused on the physical and biological performance with laboratory-aerosolized microorganisms. The results showed that the BioSampler has better physical collection efficiency for B. subtilis and P. fluororescens than the AGI-30 when water was used as the collection fluid and the sampling how rate ranged from 8.5 L min (- 1) to the standard 12.5 L min (- 1) Additionally, the BioSampler provided equivalent or better microbial recovery for the 2 species than the AGI-30 did. The swirling motion of the collection liquid in the BioSampler generates very few bubbles and therefore causes minimal reentrainment of already collected microorganisms. In contrast to the AGI-30, the BioSampler can be used very effectively with nonevaporating liquids, such as mineral oil or glycerol. Mineral oil was found to be a suitable collection fluid for culture analysis, whereas glycerol can be used only for nonculture assays, such as the polymerase chain reaction. By using a more viscous, nonevaporating fluid, the BioSampler can be used for long-term sampling of low airborne bacterial concentrations, while the AGI-30 impinger, filled with a standard evaporating fluid, can only be used for up to about 30 min.
引用
收藏
页码:184 / 196
页数:13
相关论文
共 21 条
  • [1] *AIHA BIOS COMM, 1997, FIELD GUID DET BIOL
  • [2] USE OF SOLID-PHASE PCR FOR ENHANCED DETECTION OF AIRBORNE MICROORGANISMS
    ALVAREZ, AJ
    BUTTNER, MP
    TORANZOS, GA
    DVORSKY, EA
    TORO, A
    HEIKES, TB
    MERTIKASPIFER, LE
    STETZENBACH, LD
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1994, 60 (01) : 374 - 376
  • [3] PCR FOR BIOAEROSOL MONITORING - SENSITIVITY AND ENVIRONMENTAL INTERFERENCE
    ALVAREZ, AJ
    BUTTNER, MP
    STETZENBACH, LD
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1995, 61 (10) : 3639 - 3644
  • [4] [Anonymous], 1997, Manual of environmental microbiology
  • [5] Evaluation of four bioaerosol samplers in the outdoor environment
    Cage, BR
    Schreiber, K
    Barnes, C
    Portnoy, J
    [J]. ANNALS OF ALLERGY ASTHMA & IMMUNOLOGY, 1996, 77 (05) : 401 - 406
  • [6] CRC, 1996, HDB CHEM PHYS
  • [7] INLET CHARACTERISTICS OF BIOAEROSOL SAMPLERS
    GRINSHPUN, SA
    CHANG, CW
    NEVALAINEN, A
    WILLEKE, K
    [J]. JOURNAL OF AEROSOL SCIENCE, 1994, 25 (08) : 1503 - 1522
  • [8] Effect of impaction, bounce and reaerosolization on the collection efficiency of impingers
    Grinshpun, SA
    Willeke, K
    Ulevicius, V
    Juozaitis, A
    Terzieva, S
    Donnelly, J
    Stelma, GN
    Brenner, KP
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 1997, 26 (04) : 326 - 342
  • [9] Effect of aerosolization on culturability and viability of gram-negative bacteria
    Heidelberg, JF
    Shahamat, M
    Levin, M
    Rahman, I
    Stelma, G
    Grim, C
    Colwell, RR
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1997, 63 (09) : 3585 - 3588
  • [10] Long-term sampling of airborne bacteria and fungi into a non-evaporating liquid
    Lin, XJ
    Reponen, TA
    Willeke, K
    Grinshpun, SA
    Foarde, KK
    Ensor, DS
    [J]. ATMOSPHERIC ENVIRONMENT, 1999, 33 (26) : 4291 - 4298