Macular Pigment in Eyes With Macular Hole Formation and Its Change After Surgery

被引:6
|
作者
Obana, Akira [1 ,2 ]
Nakazawa, Risa [1 ]
Noma, Saki [1 ]
Sasano, Hiroyuki [1 ]
Gohto, Yuko [1 ]
机构
[1] Seirei Hamamatsu Gen Hosp, Dept Ophthalmol, Hamamatsu, Shizuoka, Japan
[2] Hamamatsu Univ, Preeminent Med Photon Educ & Res Ctr, Inst Med Photon Res, Dept Med Spect,Sch Med, Hamamatsu, Shizuoka, Japan
来源
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY | 2020年 / 9卷 / 11期
关键词
macular pigment; macular hole; Muller cell cone; outer plexiform layer; MEMBRANE FLAP TECHNIQUE; HEIDELBERG SPECTRALIS; ASSOCIATION; ZEAXANTHIN; THICKNESS; RETINA; LUTEIN;
D O I
10.1167/tvst.9.11.28
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To observe the macular pigment (MP) appearances in eyes with macular hole (MH) and clarify the origin of the appearances. The mechanisms underlying the development of MH are discussed based on the observation of MR. Methods: This observational case series included 33 eyes of 31 patients with MH who underwent vitrectomy. The MP optical density was measured using the two-wavelength fundus autofluorescence technique. The exact localization of MP was evaluated by comparing MP distribution images and optical coherent tomography B-scan images. Results: MP was missing at the MH. The area of the MP defect corresponded with the area of the defect of outer plexiform layer. MP was present in the retinal flap in stage 2 MH that included glia (Muller cells) and plexiform layers and in the operculum in stage 3 MH, which mainly comprised Muller cells. Cystic spaces in the outer plexiform layer surrounding stage 3 and 4 MHs showed a honeycomb appearance on MP images. MP reappeared to form an irregularly shaped pigment plane after surgical closure of MH. The MP optical volume did not change before and after surgery. Fellow eyes with a central dip in MP distribution subsequently developed MH. Conclusions: The characteristic appearances of MP at the MH were attributed to MP in the plexiform layers and Muller cell cones. A central dip of MP distribution might be a sign of Muller cell cone damage that proceeds with MH formation. Translational Relevance: Observation of MP was useful for understanding the mechanisms of MH formation.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 50 条
  • [41] Residual triamcinolone acetonide at macular hole after vitreous surgery
    Kumar, Atul
    Sinha, Subijay
    Gupta, Anoop
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2010, 58 (03) : 232 - 234
  • [42] Temporal changes in foveal contour after macular hole surgery
    Kim, J. H.
    Kang, S. W.
    Lee, E. J.
    Kim, J.
    Kim, S. J.
    Ahn, J.
    EYE, 2014, 28 (11) : 1355 - 1363
  • [43] VISUAL OUTCOME CORRELATES WITH INNER MACULAR VOLUME IN EYES WITH SURGICALLY CLOSED MACULAR HOLE
    Pilli, Suman
    Zawadzki, Robert J.
    Werner, John S.
    Park, Susanna S.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2012, 32 (10): : 2085 - 2095
  • [44] Progressive Changes of Regional Macular Thickness After Macular Hole Surgery With Internal Limiting Membrane Peeling
    Kumagai, Kazuyuki
    Hangai, Masanori
    Larson, Eric
    Ogino, Nobuchika
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (07) : 4491 - 4497
  • [45] Visual Outcomes of Macular Hole Surgery
    Khaqan, Hussain Ahmad
    Lubna
    Jameel, Farrukh
    Muhammad
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2016, 26 (10): : 839 - 842
  • [46] Macular Hole Surgery as a Historical Perspective
    Kumagai, Kazuyuki
    Horie, Eiji
    Fukami, Marie
    Furukawa, Mariko
    CLINICAL OPHTHALMOLOGY, 2024, 18 : 1981 - 1989
  • [47] Use of air in macular hole surgery
    Deepak Gupta
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2010, 248 : 907 - 908
  • [48] Macular hole surgery with silicone oil
    Kumar, V
    Banerjee, S
    Loo, AV
    Callear, AB
    Benson, MT
    EYE, 2002, 16 (02) : 121 - 125
  • [49] Macular hole surgery today - A survey
    Haritoglou, C.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2007, 224 (10) : 755 - 762
  • [50] Macular hole surgery with air tamponade
    Gesser, C.
    Eckert, T.
    Eckardt, U.
    Porkert, U.
    Eckardt, C.
    OPHTHALMOLOGE, 2010, 107 (11): : 1043 - +