Optimal sizing and energy scheduling of photovoltaic-battery systems under different tariff structures

被引:76
|
作者
Talent, Orlando [1 ]
Du, Haiping [1 ]
机构
[1] Univ Wollongong, Sch Elect Comp & Telecommun Engn, Wollongong, NSW 2500, Australia
关键词
MILP; Battery; PV-Battery; Optimisation; Tariff; 100-PERCENT RENEWABLE ELECTRICITY; DISPATCH SCHEDULE; STORAGE; OPTIMIZATION; METHODOLOGY; SCENARIOS; BENEFIT; DESIGN; MARKET;
D O I
10.1016/j.renene.2018.06.016
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper builds upon previous research to develop a new mixed integer linear program (MILP) for optimal PV-battery sizing and energy scheduling. Unlike previous formulations, the MILP optimises under both time-of-use (TOU) and demand tariff structures. Optimisation is based on the highest system net present value (NPV). One residential and one commercial customer are used as case studies to contrast optimisation under TOU and demand tariff structures. Optimal PV-battery sizing is not found to be affected by the tariff structures analysed. Optimal solutions under both tariffs prefer larger PV systems coupled with small battery systems. Energy consumption from the grid under TOU tariff optimisation reflects a scaled profile of the consumer's energy demand curve. Peak consumption from the grid is heavily reduced under demand tariff optimisation to decrease the associated demand charge. In the residential case study, peak grid consumption over one year is reduced from 5.98 kWh to 2.25 kWh under demand tariff optimisation. In the commercial case study, peak grid consumption over one year is reduced from 450.3 kWh to 348.6 kWh. The reduction of peak grid consumption is achieved by using the stored energy in the battery. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:513 / 526
页数:14
相关论文
共 50 条
  • [31] Provision of demand response by French prosumers with photovoltaic-battery systems in multiple markets
    Clastres, Cedric
    Rebenaque, Olivier
    Jochem, Patrick
    ENERGY SYSTEMS-OPTIMIZATION MODELING SIMULATION AND ECONOMIC ASPECTS, 2023, 14 (03): : 869 - 892
  • [32] Optimal battery schedule for grid-connected photovoltaic-battery systems of office buildings based on a dynamic programming algorithm
    Li, Yi
    Peng, Jinqing
    Jia, He
    Zou, Bin
    Hao, Bin
    Ma, Tao
    Wang, Xiaoyang
    JOURNAL OF ENERGY STORAGE, 2022, 50
  • [33] Optimal sizing and energy scheduling of isolated microgrid considering the battery lifetime degradation
    Sufyan, Muhammad
    Abd Rahim, Nasrudin
    Tan, ChiaKwang
    Muhammad, Munir Azam
    Raihan, Siti Rohani Sheikh
    PLOS ONE, 2019, 14 (02):
  • [34] Optimal scheduling of a renewable based microgrid considering photovoltaic system and battery energy storage under uncertainty
    Luo, Liang
    Abdulkareem, Sarkew S.
    Rezvani, Alireza
    Miveh, Mohammad Reza
    Samad, Sarminah
    Aljojo, Nahla
    Pazhoohesh, Mehdi
    JOURNAL OF ENERGY STORAGE, 2020, 28
  • [35] Optimal sizing of grid-connected rooftop photovoltaic and battery energy storage for houses with electric vehicle
    Merrington, Sarah
    Khezri, Rahmat
    Mahmoudi, Amin
    IET SMART GRID, 2023, 6 (03) : 297 - 311
  • [36] Comparison of optimum design, sizing, and economic analysis of standalone photovoltaic/battery without and with hydrogen production systems
    Nordin, Nur Dalilah
    Rahman, Hasimah Abdul
    RENEWABLE ENERGY, 2019, 141 : 107 - 123
  • [37] A multi-year two-stage stochastic programming model for optimal design and operation of residential photovoltaic-battery systems
    Zheng, Zhuang
    Li, Xin
    Pan, Jia
    Luo, Xiaowei
    ENERGY AND BUILDINGS, 2021, 239
  • [38] A New Approach for Optimal Sizing of Standalone Photovoltaic Systems
    Khatib, Tamer
    Mohamed, Azah
    Sopian, K.
    Mahmoud, M.
    INTERNATIONAL JOURNAL OF PHOTOENERGY, 2012, 2012
  • [39] Optimal Sizing of Battery Energy Storage Systems Considering Cooperative Operation with Microgrid Components
    Takano, Hirotaka
    Hayashi, Ryosuke
    Asano, Hiroshi
    Goda, Tadahiro
    ENERGIES, 2021, 14 (21)
  • [40] Optimal sizing of a residential PV-battery backup for an intermittent primary energy source under realistic constraints
    Khoury, J.
    Mbayed, R.
    Salloum, G.
    Monmasson, E.