A system to use electromagnetic tracking for the quality assurance of brachytherapy catheter digitization

被引:52
|
作者
Damato, Antonio L. [1 ]
Viswanathan, Akila N. [1 ]
Don, Sarah M. [1 ]
Hansen, Jorgen L. [1 ]
Cormack, Robert A. [1 ]
机构
[1] Brigham & Womens Hosp, Dana Farber Canc Inst, Dept Radiat Oncol, Boston, MA 02115 USA
关键词
brachytherapy; quality assurance; electromagnetic tracking; UNCERTAINTIES; ACCURACY;
D O I
10.1118/1.4894710
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the use of a system using electromagnetic tracking (EMT), post-processing and an error-detection algorithm for detecting errors and resolving uncertainties in high-dose-rate brachytherapy catheter digitization for treatment planning. Methods: EMT was used to localize 15 catheters inserted into a phantom using a stepwise acquisition technique. Five distinct acquisition experiments were performed. Noise associated with the acquisition was calculated. The dwell location configuration was extracted from the EMT data. A CT scan of the phantom was performed, and five distinct catheter digitization sessions were performed. No a priori registration of the CT scan coordinate system with the EMT coordinate system was performed. CT-based digitization was automatically extracted from the brachytherapy plan DICOM files (CT), and rigid registration was performed between EMT and CT dwell positions. EMT registration error was characterized in terms of the mean and maximum distance between corresponding EMT and CT dwell positions per catheter. An algorithm for error detection and identification was presented. Three types of errors were systematically simulated: swap of two catheter numbers, partial swap of catheter number identification for parts of the catheters (mix), and catheter-tip shift. Error-detection sensitivity (number of simulated scenarios correctly identified as containing an error/number of simulated scenarios containing an error) and specificity (number of scenarios correctly identified as not containing errors/number of correct scenarios) were calculated. Catheter identification sensitivity (number of catheters correctly identified as erroneous across all scenarios/number of erroneous catheters across all scenarios) and specificity (number of catheters correctly identified as correct across all scenarios/number of correct catheters across all scenarios) were calculated. The mean detected and identified shift was calculated. Results: The maximum noise +/- 1 standard deviation associated with the EMT acquisitions was 1.0 +/- 0.1 mm, and the mean noise was 0.6 +/- 0.1 mm. Registration of all the EMT and CT dwell positions was associated with a mean catheter error of 0.6 +/- 0.2 mm, a maximum catheter error of 0.9 +/- 0.4 mm, a mean dwell error of 1.0 +/- 0.3 mm, and a maximum dwell error of 1.3 +/- 0.7 mm. Error detection and catheter identification sensitivity and specificity of 100% were observed for swap, mix and shift (>= 2.6 mm for error detection; >= 2.7 mm for catheter identification) errors. A mean detected shift of 1.8 +/- 0.4 mm and a mean identified shift of 1.9 +/- 0.4 mm were observed. Conclusions: Registration of the EMT dwell positions to the CT dwell positions was possible with a residual mean error per catheter of 0.6 +/- 0.2 mm and a maximum error for any dwell of 1.3 +/- 0.7 mm. These low residual registration errors show that quality assurance of the general characteristics of the catheters and of possible errors affecting one specific dwell position is possible. The sensitivity and specificity of the catheter digitization verification algorithm was 100% for swap and mix errors and for shifts >= 2.6 mm. On average, shifts >= 1.8 mm were detected, and shifts >= 1.9 mm were detected and identified. (C) 2014 American Association of Physicists in Medicine.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] A comprehensive quality assurance protocol for electromagnetic tracking in brachytherapy
    Duerrbeck, Christopher
    Gomez-Sarmiento, Isaac Neri
    Androulakis, Ioannis
    Sauer, Birte Christina
    Kolkman-Deurloo, Inger-Karine
    Bert, Christoph
    Beaulieu, Luc
    MEDICAL PHYSICS, 2024, 51 (05) : 3184 - 3194
  • [2] Catheter Digitization in High-Dose-Rate Brachytherapy with the Assistance of An Electromagnetic (EM) Tracking System
    Damato, A. L.
    Bhagwat, M. S.
    Buzurovic, I.
    Devlin, P. M.
    Friesen, S.
    Hansen, J. L.
    Kapur, T.
    Lee, L. J.
    Mehrtash, A.
    Nguyen, P. L.
    O' Farrell, D.
    Wang, W.
    Viswanathan, A. N.
    Cormack, R. A.
    MEDICAL PHYSICS, 2014, 41 (06) : 487 - 488
  • [3] Quality assurance for clinical implementation of an electromagnetic tracking system
    Santanam, Lakshmi
    Noel, Camille
    Willoughby, Twyla R.
    Esthappan, Jacqueline
    Mutic, Sasa
    Klein, Eric E.
    Low, Daniel A.
    Parikh, Parag J.
    MEDICAL PHYSICS, 2009, 36 (08) : 3477 - 3486
  • [4] Influence and compensation of patient motion in electromagnetic tracking based quality assurance in interstitial brachytherapy of the breast
    Duerrbeck, Christopher
    Gulde, Sarah
    Abu-Hossin, Nadin
    Fietkau, Rainer
    Strnad, Vratislav
    Bert, Christoph
    MEDICAL PHYSICS, 2022, 49 (04) : 2652 - 2662
  • [5] Electromagnetic tracking (EMT) technology for improved treatment quality assurance in interstitial brachytherapy
    Kellermeier, Markus
    Herbolzheimer, Jens
    Kreppner, Stephan
    Lotter, Michael
    Strnad, Vratislav
    Bert, Christoph
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (01): : 211 - 222
  • [6] Electromagnetic tracking for treatment verification in interstitial brachytherapy
    Bert, Christoph
    Kellermeier, Markus
    Tanderup, Kari
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2016, 8 (05) : 448 - 453
  • [7] Error detection using an electromagnetic tracking system in multi-catheter breast interstitial brachytherapy
    Masitho, Siti
    Kallis, Karoline
    Strnad, Vratislav
    Fietkau, Rainer
    Bert, Christoph
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (20):
  • [8] Introduction of a hybrid treatment delivery system used for quality assurance in multi-catheter interstitial brachytherapy
    Kallis, Karoline
    Kreppner, Stephan
    Lotter, Michael
    Fietkau, Rainer
    Strnad, Vratislav
    Bert, Christoph
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (09):
  • [9] Electromagnetic tracking in interstitial brachytherapy: A systematic review
    Sauer, Birte Christina
    Duerrbeck, Christopher
    Bert, Christoph
    FRONTIERS IN PHYSICS, 2022, 10
  • [10] On the use of multi-dimensional scaling and electromagnetic tracking in high dose rate brachytherapy
    Goetz, Th I.
    Ermer, M.
    Salas-Gonzalez, D.
    Kellermeier, M.
    Strnad, V.
    Bert, Ch
    Hensel, B.
    Tome, A. M.
    Lang, E. W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (20): : 7959 - 7980