Eight-color panel for immune phenotype monitoring by flow cytometry

被引:8
作者
Cardoso, Chandra Chiappin [1 ,2 ]
Santos-Silva, Maria Claudia [1 ,2 ,3 ]
机构
[1] Fed Univ Santa Catarina UFSC, Flow Cytometry Serv, Div Clin Anal, Univ Hosp, BR-88040900 Florianopolis, SC, Brazil
[2] Fed Univ Santa Catarina UFSC, Postgrad Program Pharm, BR-88040900 Florianopolis, SC, Brazil
[3] Fed Univ Santa Catarina UFSC, Clin Anal Dept, Hlth Sci Ctr, BR-88040900 Florianopolis, SC, Brazil
关键词
Immune cells; Peripheral blood; Immunophenotyping; Flow cytometry; REGULATORY DENDRITIC CELLS; HUMAN-LEUKOCYTE ANTIGEN; HUMAN PERIPHERAL-BLOOD; EXPRESSING HLA-DR; MEMORY T-CELLS; SUBSET; LYMPHOCYTES; MOLECULES; DIAGNOSIS; PROFILE;
D O I
10.1016/j.jim.2019.03.010
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Flow cytometry (FC) is a fast and highly informative technology that has gained prominence in immune phenotype monitoring. FC standardization is crucial to obtain reliable results that are comparable among laboratories and immune monitoring studies, as this method is influenced by several variables, including equipment, reagents, staining procedures, and pre-analytical and analytical factors. Recent studies have standardized antibody panels and analytical procedures to analyze circulating immune cells in peripheral blood (PB). However, these panels cannot be adapted for laboratories that perform eight-color FC with liquid reagents. The aim of this study was to design and test an eight-color panel, intended to phenotype the main immune cell subsets in PB using liquid reagents and fresh whole blood samples. Samples were collected from healthy individuals recruited from staff and students and from six chemotherapy patients with leukopenia. The antibody panel was designed on the basis of previous studies. Quality controls comprised antibody titration, fluorescence minus one controls, internal controls, and compensation controls. Samples were analyzed by two operators using an eight-color three-laser FACSCanto II flow cytometer (BD Biosciences, USA) and Infinicyt software (Cytognos, Spain). The proposed eight-color panel is composed of six tubes. Analysis of these tubes allowed evaluation of frequencies and classification of various immune cells, such as naive T, central memory T, effector memory T, CDRA(+) effector memory T, activated T, and regulatory T cells; class-switched B, non-switched B, memory B, regulatory B cells, and plasmablasts; myeloid and plasmacytoid dendritic cells, classical and non-classical monocytes; and immature neutrophils. Immunophenotyping of leukocytes using the proposed panel was efficient to correctly differentiate the majority of immune cell subtypes. It is a promising tool to determine the immunological profile of patients in clinical trials and establish associations with disease prognosis, complications, and outcomes.
引用
收藏
页码:40 / 48
页数:9
相关论文
共 50 条
  • [1] Performance of a novel eight-color flow cytometry panel for measurable residual disease assessment of chronic lymphocytic leukemia
    Chen, Xiao
    Chen, Xia
    Zhao, Sishu
    Shi, Yu
    Zhang, Ninghan
    Guo, Zhen
    Qiao, Chun
    Jin, Huimin
    Zhu, Liying
    Zhu, Huayuan
    Li, Jianyong
    Wu, Yujie
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2024, 106 (03) : 181 - 191
  • [2] Minimal residual disease detection of leukemic cells in ovarian cortex by eight-color flow cytometry
    Amiot, Clotilde
    Angelot-Delettre, Fanny
    Zver, Tristan
    Alvergnas-Vieille, Magalie
    Saas, Philippe
    Garnache-Ottou, Francine
    Roux, Christophe
    HUMAN REPRODUCTION, 2013, 28 (08) : 2157 - 2167
  • [3] Polychromatic (eight-color) slide-based cytometry for the phenotyping of leukocyte, NK, and NKT subsets
    Mittag, A
    Lenz, D
    Gerstner, AOH
    Sack, U
    Steinbrecher, M
    Koksch, M
    Raffael, A
    Bocsi, J
    Tárnok, A
    CYTOMETRY PART A, 2005, 65A (02) : 103 - 115
  • [4] Detection of Minimal Residual Disease in Mantle Cell Lymphoma-Establishment of Novel Eight-Color Flow Cytometry Approach
    Chovancova, Jana
    Bernard, Tomas
    Stehlikova, Olga
    Salek, David
    Janikova, Andrea
    Mayer, Jiri
    Doubek, Michael
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2015, 88 (02) : 92 - 100
  • [5] Eight-color multiparameter flow cytometry (EuroFlow-NGF) is as sensitive as next-generation sequencing in detecting minimal/measurable residual disease in autografts of patients with multiple myeloma
    Urushihara, Ryota
    Takezako, Naoki
    Yoroidaka, Takeshi
    Yamashita, Takeshi
    Murata, Ryoichi
    Satou, Kenji
    Nakao, Shinji
    Takamatsu, Hiroyuki
    EJHAEM, 2023, 4 (01): : 184 - 191
  • [6] Performance of eight-color dry antibody reagent in the detection of minimal residual disease in chronic lymphocytic leukemia samples
    Bento, Laiz
    Correia, Rodolfo
    de Sousa, Flavia
    Vaz, Andressa
    Pedro, Eduardo
    Schimidell, Daniela
    Millan, Nadila
    Passaro, Marilia
    Barroso, Rodrigo
    Bacal, Nydia
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2020, 98 (06) : 529 - 535
  • [7] Eight-color immunophenotyping of T-, B-, and NK-cell subpopulations for characterization of chronic immunodeficiencies
    Boldt, Andreas
    Borte, Stephan
    Fricke, Stephan
    Kentouche, Karim
    Emmrich, Frank
    Borte, Michael
    Kahlenberg, Franka
    Sack, Ulrich
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2014, 86 (03) : 191 - 206
  • [8] Modeling flow cytometry data for cancer vaccine immune monitoring
    Frelinger, Jacob
    Ottinger, Janet
    Gouttefangeas, Cecile
    Chan, Cliburn
    CANCER IMMUNOLOGY IMMUNOTHERAPY, 2010, 59 (09) : 1435 - 1441
  • [9] Flow cytometry in the diagnosis and monitoring of acute leukemia in children
    Wood, Brent L.
    JOURNAL OF HEMATOPATHOLOGY, 2015, 8 (03) : 191 - 199
  • [10] Modeling flow cytometry data for cancer vaccine immune monitoring
    Jacob Frelinger
    Janet Ottinger
    Cécile Gouttefangeas
    Cliburn Chan
    Cancer Immunology, Immunotherapy, 2010, 59 : 1435 - 1441