Damage Detection and Evaluation for an In-Service Shield Tunnel Based on the Monitored Increment of Neutral Axis Depth Using Long-Gauge Fiber Bragg Grating Sensors

被引:9
作者
Shen, Sheng [1 ]
Lv, Huaxin [2 ]
Ma, Sheng-Lan [3 ]
机构
[1] Fuzhou Univ, Coll Civil Engn, Fuzhou 350108, Fujian, Peoples R China
[2] Zhongtian Construct Grp Zhejiang Steel Struct Co, Hangzhou 310008, Zhejiang, Peoples R China
[3] Fujian Univ Technol, Fujian Prov Key Lab Adv Technol & Informatizat Ci, Fuzhou 350118, Fujian, Peoples R China
来源
SENSORS | 2019年 / 19卷 / 08期
关键词
damage detection; damage evaluation; shield tunnel; neutral axis depth; long-gauge Fiber Bragg Grating sensors; SHEARING DISLOCATION; STRUCTURAL RESPONSE; METRO TUNNEL; BEHAVIOR; SHANGHAI; SYSTEM; RIVER;
D O I
10.3390/s19081840
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
It is difficult to detect and evaluate the structural damage in a shield tunnel during operation because many traditional techniques based on the observation of vibrations are limited in daily monitoring in tunnels. Thus, the curvature radius of a static longitudinal settlement curve is used to identify the residual health and safety of an in-service shield tunnel. However, there are still two problems. The curvature radius is suitable for a qualitative judgment rather than a quantitative evaluation for longitudinal damage detection. Moreover, the curvature radius, which is calculated from the measured settlements of three neighboring points, gives an average damage degree in a wide scope only and is difficult to use to identify the damage's precise location. By means of the analysis of three kinds of longitudinal failure modes in a shield tunnel, this paper proposes: (1) a damage detection method based on the monitored increment of the neutral axis depth; and (2) an index to evaluate longitudinal damage. The index is composed of the residual ratios of the equivalent flexural stiffness (HFM1) and the equivalent shear stiffness (HFM3). The neutral axis position and the proposed damage index can be determined using long-gauge Fiber Bragg Grating sensors. Results from numerical simulations show that the deviation between the HFM1 and the true value residual ratio of the equivalent flexural stiffness is no more than 1.7%. The HFM3 is equal to its true value in the entire damage process. A loading experiment for a scaled-down model of a shield tunnel using long-gauge Fiber Bragg Grating sensors indicated that the errors in the HFM1 were no more than 5.0% in the case of early damage development (HFM1 0.5). The maximum error did not exceed 9.0% even under severe damage conditions in the model. Meanwhile, the HFM3 also coincided with its true value in the entire testing process.
引用
收藏
页数:25
相关论文
共 54 条
[1]  
[Anonymous], 2005, THESIS
[2]  
[Anonymous], 2007, EFFECT DIFFERENT HOR
[3]   Experimental and analytical study of the structural response of segmental tunnel linings based on an in situ loading test. Part 2: Numerical simulation [J].
Arnau, Oriol ;
Molins, Climent .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2011, 26 (06) :778-788
[4]  
Balageas D., 2006, Structural Health Monitoring
[5]   Structural monitoring for the cyclic behaviour of concrete tunnel lining sections using FBG sensors [J].
Bursi, Oreste S. ;
Tondini, Nicola ;
Fassin, Manuel ;
Bonelli, Alessio .
STRUCTURAL CONTROL & HEALTH MONITORING, 2016, 23 (04) :749-763
[6]   Nonlinear Response Characteristics of Undersea Shield Tunnel Subjected to Strong Earthquake Motions [J].
Chen, Guoxing ;
Ruan, Bin ;
Zhao, Kai ;
Chen, Weiyun ;
Zhuang, Haiyang ;
Du, Xiuli ;
Khoshnevisan, Sara ;
Juang, Charng Hsein .
JOURNAL OF EARTHQUAKE ENGINEERING, 2020, 24 (03) :351-380
[7]   A study of liquefaction related damages on shield tunnels [J].
Chou, HS ;
Yang, CY ;
Hsieh, BJ ;
Chang, SS .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2001, 16 (03) :185-193
[8]   Fiber Optic Sensor Embedment Study for Multi-Parameter Strain Sensing [J].
Drissi-Habti, Monssef ;
Raman, Venkadesh ;
Khadour, Aghiad ;
Timorian, Safiullah .
SENSORS, 2017, 17 (04)
[9]   Damage detection of metro tunnel structure through transmissibility function and cross correlation analysis using local excitation and measurement [J].
Feng, Lei ;
Yi, Xiaohua ;
Zhu, Dapeng ;
Xie, Xiongyao ;
Wang, Yang .
MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2015, 60-61 :59-74
[10]   Risk Analysis of the Opening of Shield-Tunnel Circumferential Joints Induced by Adjacent Deep Excavation [J].
Han, Jian-yong ;
Zhao, Wen ;
Jia, Peng-jiao ;
Guan, Yong-ping ;
Chen, Yang ;
Jiang, Bao-feng .
JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2018, 32 (01)