Pain and bleeding associated with trephine biopsy

被引:7
|
作者
Valebjorg, Therese [1 ,2 ]
Spahic, Boris [2 ]
Bremtun, Fredrik [2 ]
Kahrs, Johannes [2 ]
Hammerstrom, Jens [3 ]
Brudevold, Robert [4 ]
Kolflaath, Jan [5 ]
Ghanima, Waleed [2 ,6 ]
机构
[1] Baerum Hosp, Dept Med, Baerum, Norway
[2] Ostfold Hosp Trust, Dept Med, Fredrikstad, Norway
[3] St Olavs Hosp, Dept Med, Trondheim, Norway
[4] Alesund Hosp, Dept Med, Alesund, Norway
[5] Ostfold Hosp Trust, Dept Anesthesiol, Fredrikstad, Norway
[6] Univ Oslo, Oslo, Norway
关键词
biopsy; bone marrow; pain; bleeding; BONE-MARROW ASPIRATION; GENERAL-ANESTHESIA; LUMBAR PUNCTURE; MORBIDITY;
D O I
10.1111/ejh.12339
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The study objectives were to determine the intensity and duration of pain, factors that may influence pain experience during and after trephine biopsy, and to assess bleeding and infectious complications related to the procedure. Patients scheduled for trephine biopsy were recruited to the study. Local anesthesia was applied in all patients. Pain intensity was recorded twice daily by the patients using the numeric rating scale (NRS). Bleeding was graded into four grades. Median age of 184 patients was 63yr. Maximum NRS level was measured at time of biopsy (T0); 167 (91%) patients experienced pain at T0. Median (Q1:Q3) NRS was 3 (1; 5). Median duration of pain was 36h. Fourteen patients reported pain for more than 7d. Significant inverse correlation was found between NRS at T0 and age. Pain duration at rest correlated with NRS at T0 and age, while pain duration in activity correlated with NRS at T0, age, and with body mass index (BMI). Mild and moderate bleeding at T0 occurred in 97 (54%) and 18 (10%) patients, respectively; no severe bleeding or infectious complications were registered. Secondary bleeding occurred in two patients; both required hospitalization. In conclusion, the study shows that despite the application of local anesthetic, more than 50% of the patients experienced pain of 3 points. Procedure-related bleeding is mild to moderate and managed by local pressure only.
引用
收藏
页码:267 / 272
页数:6
相关论文
共 50 条
  • [11] Haematoma caused by bone marrow aspiration and trephine biopsy
    Sarigianni, Maria
    Vlachaki, Efthymia
    Chissan, Sofia
    Klonizakis, Filippos
    Vetsiou, Evaggelia
    Anastasiadou, Kyriaki I.
    Ioannidou-Papagiannaki, Elissavet
    Klonizakis, Ioannis
    HEMATOLOGY REPORTS, 2011, 3 (03) : 78 - 79
  • [12] Bleeding risk and complications associated with percutaneous ultrasound-guided liver biopsy in cats
    Pavlick, Michelle
    Webster, Cynthia R. L.
    Penninck, Dominique G.
    JOURNAL OF FELINE MEDICINE AND SURGERY, 2019, 21 (06) : 529 - 536
  • [13] Strategies of pain reduction during the bone marrow biopsy
    Nikolaj Hjortholm
    Emil Jaddini
    Kazimierz Hałaburda
    Emilian Snarski
    Annals of Hematology, 2013, 92 : 145 - 149
  • [14] A prospective survey on trephine biopsy of bone and bone marrow: an experience with 274 Indian patients’ biopsies
    Rahul Nadda
    Ramjee Repaka
    Nabhajit Mallik
    Ashish Kumar Sahani
    European Journal of Medical Research, 28
  • [15] The efficacy of bupivacaine with adrenaline in reducing pain and bleeding associated with breast reduction: a prospective trial
    Metaxotos, NG
    Asplund, O
    Hayes, M
    BRITISH JOURNAL OF PLASTIC SURGERY, 1999, 52 (04): : 290 - 293
  • [16] Utility of simultaneous assessment of bone marrow aspirates and trephine biopsy sections in various haematological disorders
    Puri, Vandana
    Sharma, Pooja
    Kotru, Mrinalini
    Sikka, Meera
    Sharma, Satendra
    IRAQI JOURNAL OF HEMATOLOGY, 2018, 7 (01) : 26 - 32
  • [17] Combined Oral Administration of Analgesia and Anxiolysis for Pain Associated with Bone Marrow Aspiration and Biopsy
    Cerchione, Claudio
    Picardi, Marco
    Pugliese, Novella
    Della Pepa, Roberta
    Gravetti, Angela
    Casoria, Aniello
    Nappi, Davide
    Ciancia, Giuseppe
    Pane, Fabrizio
    Martinelli, Vincenzo
    CLINICAL LYMPHOMA MYELOMA & LEUKEMIA, 2018, 18 : S303 - S303
  • [18] FACTORS ASSOCIATED WITH COPPER-T IUD REMOVAL FOR BLEEDING PAIN - A MULTIVARIATE-ANALYSIS
    ZHANG, J
    CONTRACEPTION, 1993, 48 (01) : 13 - 21
  • [19] Morphometric classification of hairy cell leukemia in bone marrow trephine biopsy
    Okon, K
    Szumera, A
    Papla, B
    Pietkun, I
    Zdunczyk, A
    Rucinska, M
    Skotnicki, AB
    Stachura, J
    ANALYTICAL AND QUANTITATIVE CYTOLOGY AND HISTOLOGY, 2003, 25 (04): : 227 - 234
  • [20] Aspiration and trephine biopsy of bone marrow of dogs and cats:: methodology and indications
    Mróz, K
    Nicpon, J
    Slawuta, P
    MEDYCYNA WETERYNARYJNA, 2005, 61 (05) : 500 - 501