Examination of Quality Control Guidelines for Digital Breast Tomosynthesis Systems in Japan

被引:0
作者
Shinohara, Norimitsu [1 ,2 ]
Akiyama, Shinobu [2 ]
Ito, Takahiro [2 ]
Okada, Satoko [2 ]
Chiba, Yoko [2 ]
Negishi, Tohru [2 ]
Hirofuji, Yoshiaki [2 ]
机构
[1] Gifu Univ Med Sci, Dept Radiol Technol, 795-1 Ichihiraga, Gifu 5013892, Japan
[2] Japanese Soc Radiol Technol Acad Res Grp, Gifu, Japan
来源
15TH INTERNATIONAL WORKSHOP ON BREAST IMAGING (IWBI2020) | 2020年 / 11513卷
关键词
Digital Breast Tomosynthesis; Quality Control; Guidelines; MAMMOGRAPHY;
D O I
10.1117/12.2564049
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
The use of mammography equipment attached to a digital breast tomosynthesis (DBT) system is widespread in Japan. Tomosynthesis exposes the breast to X-rays continuously (or in pulses) at different angles in a single scan, yielding multiple projection images. Arbitrary multi-slice images can be reconstructed from the projection images after scanning. However, DBT increases the exposure dose compared to mammography. Therefore, it is necessary to rapidly establish performance evaluation procedures and quality control procedures for DBT. In this study, we conduct quality control measurements on DBT systems sold in Japan by five different companies and examine feasible common items. The purpose of the study was to establish a quality control method for DBT systems in Japan. The measurements were performed based on the EUREF breast tomosynthesis quality control protocol version 1.03. In this study, we attempted to measure 18 items in DBT systems. We examined whether the 18 items could be measured using each system; however, this was not an evaluation of equipment performance based on the measured values. There were some quality control items that were difficult to complete due to the specifications of a DBT system, such as equipment that required pressure during DBT operation, problems due to the shape of the bucky, and equipment that did not have stationary mode. There were also problems related to the availability of measurement data, such as with equipment that could not retrieve projection data and reconstructed data. This study clarified points to be considered for establishing common quality control items. In the future, we will carefully refer to the recently published IEC 61223-3-6, consider international harmonization, and establish DBT guidelines customized for the Japanese market.
引用
收藏
页数:7
相关论文
共 8 条
  • [1] [Anonymous], 2018, CANC STAT FACTS COMM
  • [2] Integration of 3D digital mammography with tomosynthesis for population breast-cancer screening (STORM): a prospective comparison study
    Ciatto, Stefano
    Houssami, Nehmat
    Bernardi, Daniela
    Caumo, Francesca
    Pellegrini, Marco
    Brunelli, Silvia
    Tuttobene, Paola
    Bricolo, Paola
    Fanto, Carmine
    Valentini, Marvi
    Montemezzi, Stefania
    Macaskill, Petra
    [J]. LANCET ONCOLOGY, 2013, 14 (07) : 583 - 589
  • [3] Comparison of Tomosynthesis Plus Digital Mammography and Digital Mammography Alone for Breast Cancer Screening
    Haas, Brian M.
    Kalra, Vivek
    Geisel, Jaime
    Raghu, Madhavi
    Durand, Melissa
    Philpotts, Liane E.
    [J]. RADIOLOGY, 2013, 269 (03) : 694 - 700
  • [4] IARC, 2018, CANC TODAY
  • [5] Japan Radiological Society and Japanese Society of Radiological Technology, 2014, JAPAN RADIOLOGICAL S
  • [6] National Cancer Center Japan, 2018, CANC INFORM SERVICE
  • [7] Comparison of Digital Mammography Alone and Digital Mammography Plus Tomosynthesis in a Population-based Screening Program
    Skaane, Per
    Bandos, Andriy I.
    Gullien, Randi
    Eben, Ellen B.
    Ekseth, Ulrika
    Haakenaasen, Unni
    Izadi, Mina
    Jebsen, Ingvild N.
    Jahr, Gunnar
    Krager, Mona
    Niklason, Loren T.
    Hofvind, Solveig
    Gur, David
    [J]. RADIOLOGY, 2013, 267 (01) : 47 - 56
  • [8] The Japan Central Organization on Quality Assurance of Breast Center Screening, 2018, ANNOUNCEMENT CLASSIF